HomeMy WebLinkAbout335697_2_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
102125642
PROJECT ADDRESS:
1431 W Raymar St
PLAN CHECK ENGINEER:
Meshkat, SeyedyahyaTEL:714
647-5831
EMAIL:
smeshkat@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
R-3, U
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
11/25/2025
INITIAL REVIEW
12/10/2025
EXPIRATION
5/24/2026
RECHECKS:
1.12/23/2025
PROJECT APPLICANT CONTACT PERSON:
2.
Rene Avarez
3.
TEL:
(951)283-2457
FAX:
VALUATION: $28,000.00
EMAIL:
rawconstructiondesign@gmail.com
FLOOD ZONE: X-06059C0257J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2022 California Residential Code (CRC); 2022 California Building Code (CBC); CMC = 2022 California Mechanical Code; CPC = 2022 California Plumbing Code; CEC = 2022 California Electrical Code; T = Table; ICC = International Code Council.
GENERAL COMMENTS:All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.2nd: Three full set of plans are required, only two sets were submitted.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5831 for an appointment.
Please see corrections on submitted plans. Red marked set must be returned with revised plans. Plans resubmitted without the red markup set may result in delayed review time and additional plancheck fees.
This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information.
The applicant shall obtain clearances/approvals for the following, prior to building permit issuance:
-Planning Division approval on the corrected/final set of drawings (647-5804). Previously
approved plans should be submitted to expedite the process.
REVIEW COMMENTS:
Note on plan: All concealed work installed without permits must be exposed for inspection to the satisfaction of the Building Inspector. This includes methods of attachment and all footings, structural members, mechanical, electrical, plumbing and insulation.
Please submit 3 sets of plans, only 2 sets are submitted.
2nd: Only two sets submitted.
Note on plan: Mechanical, electrical and plumbing are not part of this plan review and approval. MEP are subject to building field inspection.
Verify the scale shown on all the drawings. Scales and dimensions do not match. All the drawings need to be drawn to scale shown on plan.
2nd: Comment not addressed. Dimensions on plan does not match the scale shown.
Provide a complete plot plan showing – (R106.2). Additional comments may arise.
Location and size of all structures on the lot.
2nd: Add dimensions to show size of all structures.
Identify all property lines and easements, streets, etc. If there isn’t any easement on property, add note: No easement exists on this property.
Distances between buildings (main house, detached garage, accessory dwelling unit, etc.).
Distances (setbacks) between buildings and property lines.
Drainage plan shall indicate how the site grading or drainage system will manage all surface water flows to be diverted away from buildings and adjoining property lines, in accordance with all applicable codes. Clarify how the drain patterns shown on North landscaping is pulling the surface water toward the building.
Clarify if windows C and H are same size as existing or not. Clarify if door 4 is same size as existing or not.
2nd: Comment not addressed. Window schedule is not calling “same size” specifically for windows C and H; add “same size” to notes. Same thing for door 4, add “same size” if not changing the size.
Height of window G shown in window schedule has discrepancy with elevations. Clarify the height and verify net clear open height meets minimum code requirements (R310).
Show existing/new landings with dimensions at exterior doors.
Bedroom 1: Carbon Monoxide Alarms – Provide carbon monoxide alarms at outside of each sleeping area, in the immediate vicinity of the bedroom(s). (R315)
2nd: Comment not addressed. Smoke detectors are required in and outside of the sleeping room (at immediate vicinity). In addition, carbon monoxide alarm is required outside of sleeping room (at immediate vicinity).
Kitchen shall be vented to the outside. On the plan, please show exhaust fan(s), and specify the range type (electric vs. gas) in kitchen. Kitchen Range Hood Airflow Rate (CFM) shall comply with Table 150.0-G
Water Heating system (water heater) – (Section 150.0(n)) Systems using gas or propane water heaters to serve individual dwelling units shall designate a space at least 2.5 feet by 2.5 feet wide and 7 feet tall suitable for the future installation of a heat pump water heater (HPWH) by meeting either A or B listed under Section 150.0(n).
If the designated space is within 3 feet from the water heater:
A dedicated 125 volt, 20 amp electrical receptacle that is connected to the electric panel with a 120/240 volt 3 conductor, 10 AWG copper branch circuit, within 3 feet from the water heater.
Isolate both ends of the unused conductor.
A reserved single pole circuit breaker space in the electrical panel adjacent to the circuit breaker
A condensate drain that allows natural draining of the water heater.
If the designated space is more than 3 feet from the water heater: see additional Code requirements.
2nd: Show the distance between provided space and the water heater.
Bathroom Exhaust Fan (Section 4.506.1)
Fans shall be ENERGY STAR compliant and be ducted to terminate outside the building
Unless functioning as a component of a whole house ventilation system, fan must be controlled by a humidity control.
Add not on plan to verify in field that the demolished door in bedroom 1 is not a load bearing wall.
Provide a detail and show on plans for connection of non-bearing interior partitions to concrete slab as required per CBC 2022, 2304.3.4.(End of Comment)