HomeMy WebLinkAbout337482_1_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101126199
PROJECT ADDRESS:
1818 E First St Unit# 550
PLAN CHECK ENGINEER:
Ahangian, KathyTEL:714
647-5812
EMAIL:
Kahangian@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V A, SPK
OCCUPANCY CLASSIFICATION(S):
R-2
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
1/12/2026
INITIAL REVIEW
2/5/2026
EXPIRATION
7/11/2026
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Enrique Murillo
3.
TEL:
(951)956-6849
FAX:
VALUATION: $30,960.00
EMAIL:
Enrique.murillo@gmail.com
FLOOD ZONE: X-06059C0277J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2022 California Residential Code (CRC); 2022 California Building Code (CBC); CMC = 2022 California Mechanical Code; CPC = 2022 California Plumbing Code; CEC = 2022 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5812 for an appointment.
Please see corrections on submitted plans. Red marked set must be returned with revised plans. Plans resubmitted without the red markup set may result in delayed review time and additional plancheck fees.
All drawings and supporting documents shall be prepared, stamped, and signed by a California licensed architect or registered professional engineer. (CRC R301.1.3, CBC 107.1 and 107.3.4.1).
This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information.
The applicant shall obtain clearances/approvals for the following, prior to building permit issuance:
-Planning Division approval on the corrected/final set of drawings (647-5804). Previously
approved plans should be submitted to expedite the process.
- Proof of Worker's Compensation Insurance shall be required at the time of permit issuance.
Provide site plan and show location of project on the site plan.
Provide roof framing plan, show location of the panels with regard to the to the roof framing members.
Provide calculation to show how the PV panels are supported.
Show number and location of solar panels support.
Provide Construction details for the attachment of the solar arrays to roof framing.
Provide weight of the ballasts and location of them on the roof plan.
Justify roof members can take additional load from ballasts.
Show number of ballasts required for the system.
Provide height of the panels.
Provide elevation to show location of Battery cabinets on the wall.
Show weight of the battery cabinets. Provide attachment detail for battery cabinet on the wall with engineering stamp.