HomeMy WebLinkAbout337838_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101126308 PROJECT ADDRESS: 2232 S Laura Linda Ln PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 1/23/2026 INITIAL REVIEW 2/6/2026 EXPIRATION 7/22/2026 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Quoc Do 3. TEL: (714)458-5374 FAX: VALUATION: $128,038.00 EMAIL: doquocpl@yahoo.com FLOOD ZONE: X-06059C0259J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2025 California Residential Code (CRC); 2025 California Building Code (CBC); CMC = 2025 California Mechanical Code; CPC = 2025 California Plumbing Code; CEC = 2025 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Police Department approval on the corrected/final set of drawings (647-5840). -Public Works Agency approval (647-5039). - School District Compliance Certificate; and a copy of the building permit application, signed by the plan check engineer, shall be required by the School District to verify the scope of the work.Refer to redlines on sheet A-002. For the purpose of determining fire separation distance, detached ADU and the existing dwelling on the same lot shall be assumed to have an imaginary line between them. Revise site related plans, floor plans and roof plans to show compliance.Where a new detached ADU is to be erected on the same lot as an existing dwelling, the location of the assumed imaginary line shall be at least 5 feet, measured perpendicularly from the exterior wall of the existing dwelling.R302.1. After revise imaginary line is set, show compliance of the ADU exterior wall, projections, and openings based on the fire separation distance to the imaginary line per CRC Table R302.1(1). Show location and construction details of fire-rated wall, eave protection and reduce roof overhang at some location to comply with code. Sheet A-101. On both floor plan and roof plan, show location and construction details of fire-rated wall, eave protection and reduce roof overhang at some location to comply with code. Provide a smoke detector outside master bedroom 1 in the immediate vicinity of the bedroom door. Provide a carbon monoxide detector outside master bedroom 1 in the immediate vicinity of the bedroom door. Revise door type #B to have 36” wide minimum to ensure 32” clear door opening will be available. R328.1.3. Sheet T-24s and plans. Update the energy performance approach to comply with 2025 California Energy Code. Revise energy calculation and relevant architectural plans. Energy review is pending. Sheet GRN-1 and sheet GRN-2. Please update the design to comply with 2025 California Green Building Standards Code. STRUCTURAL Revise the project address to “2232 S Laura Linda Lane, Santa Ana CA 92704”. Please ensure the correct address is updated throughout the construction document. For example, address on the title block of every sheet, and title page on structural calculations. Please update structural design to comply with 2025 California Building Code. Please update structural plans and calculation with newly adopted reference: 2025 CBC, ASCE 7-22, and NDS 2024. Please ensure structural design software is up to date. Sheet S-1. Framing plan. Provide detail to design continuous rafter ties between ceiling joists on grid line 2 near grid line B by the main entrance landing. Sheet S-1. Provide HDU2 at each end of the shear wall on grid line B. Sheet S-1. Provide spread footing (F1) design, dimensions, embedment and reinforcement on plan. END OF COMMENTS