HomeMy WebLinkAbout337055_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org M PLAN CHECK NO: 101126069 PROJECT ADDRESS: 3600 S Susan St PLAN CHECK ENGINEER: Ahangian, KathyTEL:714 647-5812 EMAIL: Kahangian@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: III B, SPK OCCUPANCY CLASSIFICATION(S): B, F-1, S-1 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 12/23/2025 INITIAL REVIEW 1/10/2026 EXPIRATION 6/21/2026 RECHECKS: 1.2/10/26 PROJECT APPLICANT CONTACT PERSON: 2. Edgar Parra 3. TEL: (626)315-2621 FAX: VALUATION: $65,000.00 EMAIL: edgar@thecitysolutions.com FLOOD ZONE: X-06059C0258J APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5812 for an appointment.Please return marked up set of drawings with corrections.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings ((714)573-6100), Please see OCFA for high piled storage rack before resubmittal) - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceNote on the Floor Plan, type and quantity of the materialstored on the storage racks.Ok 2/10/26Lower portions of posts exposed to damage by forklift trucks or other moving equipment shall have protective devices. If not so protected, at the option of the building official, the rack structure may: (1) be designed to maintain its full design load capacity at allowable stresses with the exposed post capacity reduced by one-half or (2) be designed to maintain its full design load capacity at 50 percent increased allowable stresses with the exposed post assumed to have no carrying capacity.Ok 2/10/26Verify thickness of existing concrete slab on the drawings.Ok 2/10/26On the drawing, “Provide minimum distance between the anchor bolts Center to any construction joints, control/expansion joints or slab cracks”.Pending 2/10/26City of Santa Ana accept 500 psf bearing pressure for slab-on-grade vertical load design, please revise calculation accordingly.Pending 2/10/26, per structural design a minimum of 76.74” x 76.74” soil area at each supporting column required , please show spacing for the column on the drawings. On the drawings, provide dimension of storage racks per calculation.Ok 2/10/26Provide elevation and calculation for over door storage rack, at the exit door.Ok 2/10/26