HomeMy WebLinkAbout337171_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101126115 PROJECT ADDRESS: 2821 S Griset Pl PLAN CHECK ENGINEER: Lo, JonathanTEL:714 647-5822 EMAIL: Jlo@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 1/5/2026 INITIAL REVIEW 2/9/2026 EXPIRATION 7/4/2026 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Qouc Do 3. TEL: (714)458-5374 FAX: VALUATION: $85,000.00 EMAIL: doquocpl@yahoo.com FLOOD ZONE: X-06059C0259J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2022 California Residential Code (CRC); 2022 California Building Code (CBC); CMC = 2022 California Mechanical Code; CPC = 2022 California Plumbing Code; CEC = 2022 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5822 for an appointment. The applicant shall obtain clearances/approvals for the following after obtaining approval from Building and Safety Division, prior to building permit issuance (CHECKED BOXES REQUIRED ONLY): ☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. ☒Public Works Agency approval (647-5039). ☐Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700). ☐Police Department approval on the corrected/final set of drawings (647-5840). ☒School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work. ☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. ☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039).Comments have been provided on drawing and calculation hard copies in relation to all comments below. Applicant must pick up red marked sets from city prior to resubmittal and return marked up set with resubmittal.DrawingsSheet A-000 Provide the following design data on the first sheet (R106.1.1) ☐Sheet Index ☐Occupancy groups (R-3/U) ☐Type of construction (V-B) ☐Automatic Fire Sprinkler (YES or NO) ☐Number of stories. ☐Flood Zone: X ☐Flood Zone: A ☐Flood Zone: AE ☐Floor area per occupancy group, including the existing structure(s) ☒Construction shall comply with the 2025 CRC, CBC, CPC, CMC, CEC, California Green Building Code, and California Energy Efficiency Standards Code editions.Sheet A-101Verify adequate lighting for existing family room. [R325]Sheet A-102Roof Note 51 – No current ICC approval found for proposed roofing. Verify and provide currently approved product.Verify where Flat Roof Notes used, remove if not used.Justify 1/300 used for attic ventilation, only gable end vents are shown, provide high/low ventilation requirement justification.Roof projection spanning within 3’-0” to 5’-0” shall have 1-hour fire rated underside or code approved alternative. Specify on plans where required and provide detail. Sheet SNAll code references shall be updated to current codes (e.g. CBC, ASCE, etc…)Sheet T-24-1Title 24 compliance shall be updated to 2025 code compliancy. Sheet GRN-1Green Building Codes shall be updated to latest 2025 code and checklist shall be fully completed by applicant.CalculationsCalculations shall be updated to current codes (e.g. CBC, ASCE, etc…)Beam: B1 – Verify beam location, beam not found on drawings. (End of Comment)