HomeMy WebLinkAbout335341_2_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101125537
PROJECT ADDRESS:
3600 S Susan St
PLAN CHECK ENGINEER:
Ahangian, KathyTEL:714
647-5812
EMAIL:
Kahangian@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
III B, SPK
OCCUPANCY CLASSIFICATION(S):
A-3, B, F-1, S-1
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
11/12/2025
INITIAL REVIEW
12/18/2025
EXPIRATION
5/11/2026
RECHECKS:
1.3/3/26
PROJECT APPLICANT CONTACT PERSON:
2.
David Jackson
3.
TEL:
(909)541-9373
FAX:
VALUATION: $200,000.00
EMAIL:
djackson0798@yahoo.com
FLOOD ZONE: X-06059C0258J
APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5812 for an appointment.Please return marked up set of drawings with corrections.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Public Works Agency approval (647-5039)
- Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceProvide calculation to justify existing roof members can take additional downward and vertical load on the members.Ok 3/3/26Sheet PC-7, identify the notes that are missing from the arrows.( see red mark)Ok 3/3/26Provide maximum height of the array.Ok 3/3/26Provide size, embedment and spacing for railing’s anchor.Ok 3/3/26 3/3/26Please identify all the items on the roof plan, if there are roof hatch and skylight show 4 feet clear pathway to them.All pages of drawings shall be signed by the engineer of record.Drawings are missing all the following sheets from last submittal ;Ballast layouts and racking layouts are missingPrevious sheet PC-1, for design dataSheet PC-2 project summarySheet PC- 3 Array site mapSheet PC-4 Typical array dimensionSheet PC-8 ballast layout 1.1Sheet PC-9 Ballast layout 1.2Sheet PC-10 Ballast layout 1.3