HomeMy WebLinkAbout332154_4_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
104124553, 55, 57
PROJECT ADDRESS:
4622 W First St
PLAN CHECK ENGINEER:
Le, TungTEL:714
647-5896
EMAIL:
Tle10@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
B
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
8/5/2025
INITIAL REVIEW
9/9/2025
EXPIRATION
2/1/2026
RECHECKS:
1.11/3/2025
PROJECT APPLICANT CONTACT PERSON:
2.1/6/26
Alexandra Dykes
3.
TEL:
(949)395-8755
FAX:
VALUATION: $9,000.00
EMAIL:
anavas@landworksdevelopmentservices.com
FLOOD ZONE: A-06059C0256J
APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Police Department approval on the corrected/final set of drawings (647-5840)Sheet A2.0: Truncated dome locate at the door landings are not allow. Please revise plan to provide concrete curb in front of the door landings and provide truncated domes at the ends where the pedestrian crosses the parking area. Relocating/shipping the accessible parking and access aisle are necessary. 2nd Review: Sheet A2.0, A2.1, A2.2 – Revise plans to provide a concrete curb between the new walkway and parking area. See marked-up plan for clarity. 3rd Review: For clarity, please revise sheet A2.0 & A2.1 to specify new 6” high concrete curb. Sheet A2.2, Proposed Floor planUnit C’s Restroom shall be accessible to the person with disabilities. Provide restroom plan with all required dimensions (similar to 1/A6.0). 2nd Review: Restroom in Unit C shall be accessible as well. Please provide details to show restroom in compliance with the accessibility requirement in Chapter 11B, Division 6. 3rd Review: Information was insufficient. Please revise restroom plans, including enlarged plans on sheet A6.0 & A6.1 to provide 60” floor clear space for the water closet, measured from the adjacent wall to the edge of the sink. (11B-604.3.1)Sheet A2.4: Please revise plan to match with revised floor plan per requirement comments above. 2nd Review: Please comply. Sheet A6.0: Revise restroom floor plan to show 60” clear floor space for the water closet. 2nd Review: Please revise plan to show 60” clear floor space for the toilet. Show dimension on the plan. 3rd Review: Information was insufficient. Please revise restroom planson sheet A6.0 & A6.1 to provide 60” floor clear space for the water closet, measured from the adjacent wall to the edge of the sink. (11B-604.3.1)Sheet A2.2: Demising wall, Detail 2/A8.0 – Demising wall shall extend full height to the roof structural framing. Please revise detail to show wall extend to the roof framing and provide 5/8” type ‘X’ gypsum board on each side. 2nd Review: Detail 2/A8.0: revise detail to show wall finish extend to roof frames above. 3rd Review: Please revise detail 2/A8.0 to show blockings between existing roof joists for the new double top plates. (End of Comment)