Loading...
HomeMy WebLinkAbout336246_4_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101125791 PROJECT ADDRESS: 3431 W Carriage Dr PLAN CHECK ENGINEER: Ahangian, KathyTEL:714 647-5812 EMAIL: Kahangian@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: III B, SPK OCCUPANCY CLASSIFICATION(S): B, F-1, S-1 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 12/1/2025 INITIAL REVIEW 1/7/2026 EXPIRATION 5/30/2026 RECHECKS: 1.2/19/26 PROJECT APPLICANT CONTACT PERSON: 2.3/18/26 Meghan Hui 3. TEL: (413)302-1457 FAX: VALUATION: $90,000.00 EMAIL: meghan.hui@hundredflowers.com FLOOD ZONE: X-06059C0258J APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5812 for an appointment.Please return marked up set of drawings with corrections.CBC Sections A106.1 and A106.3.4.1, All drawings and supporting documents shall be prepared, stamped and signed by a California licensed architect or registered civil engineer.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings ((714)573-6100) - Public Works Agency approval (647-5039) - Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceSubmit a signed copy of the contract showing labor and materials for all work to be done under the subject building permit application. The plan check engineer may accept the contract price as the valuation of improvements for unique/unusual projects in lieu of using a cost per square foot basis.Provide the following;Pending 2/19/26, identify all the lines on the site plan. - Provide a fully dimensioned site plan on each set of plans.Provide complying exiting plan for all area. Ok 2/19/26Show all exit doors on the floor plan and site plan.Ok 2/19/26EXIT ACCESS. That portion of a means of egress system that leads from any occupied portion of a building or structure to an exit. Ok 2/19/26 Exterior exit doors shall lead directly to the exit discharge or the public way.Ok 2/19/26Exit illumination and exit sign requirements in accordance with CBC Section 1013 shall be shown on the drawings. Be specific as to the type of exit signs to be installed.Ok 2/19/26Provide height of all shelving in each room.Pending , 3/18/26, show type on the shelving in each room.Provide minimum 44” clearance between shelving. (see red mark)Ok 2/19/26Provide minimum 60” landing at all flower door’s room.Ok 2/19/26Room 122 ( Veg room) Provide minimum 60” +44” clearance when racks are moving.Ok 2/19/26Show minimum 18” clearance to the strike edge of doors for prop rooms.Ok 2/19/26 Provide attachment detail for all shelving over 6’ high.Pending 2/19/26 , calculation shows 8’ tall storage rack, sheet A1-103, shows 10’10”, please revise drawings to match calculation.Pending 3/18/26, Provide attachment detail ( anchorage ) for the shelving on the floor . provide attachment detail for 10’10” rolling (moving ) shelving. Verbiage is not sufficient.