HomeMy WebLinkAbout337752_3_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101126283
PROJECT ADDRESS:
816 S Main St
PLAN CHECK ENGINEER:
Ahangian, KathyTEL:714
647-5812
EMAIL:
Kahangian@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
N/A
OCCUPANCY CLASSIFICATION(S):
N/A
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
1/21/2026
INITIAL REVIEW
1/25/2026
EXPIRATION
7/20/2026
RECHECKS:
1.2/19/26
PROJECT APPLICANT CONTACT PERSON:
2.
JeanelleHeaston
3.
TEL:
(909)633-4094
FAX:
VALUATION: $12,000.00
EMAIL:
jeanelleheaston@sbcglobal.net
FLOOD ZONE: X-06059C0276J
APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5812 for an appointment.Please return marked up set of drawings with corrections.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Fire Department approval on the corrected/final sets of drawings ((714)573-6100)
- Public Works Agency approval (647-5039), please contact PW ,if WQMP approval required on this project.
- Proof of Worker’s Compensation Insurance shall be required at the time of permit issuanceSubmit a signed copy of the contract showing labor and materials for all work to be done under the subject building permit application. The plan check engineer may accept the contract price as the valuation of improvements for unique/unusual projects in lieu of using a cost per square foot basis.Please verify if there is any re-slurry for the parking lot. Ok 2/19/26CBC Section 1022.2.2, Exterior exit doors shall lead directly to the exit discharge or the public way.Pending 2/19/26, exit door required from a parking lot and exit from the building ( through fence area)CBC Sections 1028.5 and 1022.1. Exiting from any occupied point in a building or structure on the subject site must be continuous, unobstructed, and undiminished to a public way. This includes gates Revise drawings to show compliance.Pending 2/19/26, required from the fenced areaProvide a man door at both gates . Doors shall be openable from inside without use of any keys.Pending 2/19/26, please see comment # 9 & 10A guide curb of minimum 4” in height shall be provided at each side of the ramp.Ok 2/19/26Section 11B-405.7.5, Doors in any position shall no reduce the minimum dimension of the ramp landing to less han 42”.Ok 2/19/26Section 11B-405.7.1. Detectable warning are not permitted within ramp landing. Pending 2/19/26, provide truncated on the right location.Show location of detail 4/A-501(sign) , on the siteplan.Ok 2/19/26Sheet A-100, sheet referenced on proposed site plan, doesn’t match sheet numbers that provided. Please revise sheet numbers accordingly.Ok 2/19/26Sheet A-501, detail 10, the code section 11B, shall apply to this project, unable to find section 1115A.5.Ok 2/19/26Section 1009.3.2, stairways shall have clear width of 48” between handrails.Ok 2/19/26Provide handrail at both sides of stairway.Ok 2/19/26Stairway’s handrail shall extend 12” at the top of stairway landing.Ok 2/19/26