Laserfiche WebLink
REV <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />EL <br />V <br />I <br />S <br /> <br />M <br />A <br />R <br />T <br />I <br />N <br />E <br />Z <br />RE <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />14 <br />2 <br />9 <br /> S <br />G <br />A <br />R <br />N <br />S <br />E <br />Y <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br />CA <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />ANSI B <br />11" X 17" <br />DATEDESCRIPTION <br />REVISIONS <br />PROJECT NAME & ADDRESS <br />DATE:05/05/2025 <br />DRAWN BY <br />ESR <br />MONA LEE SOLAR <br />PROJECT DATA GENERAL NOTES VICINITY MAP <br />SHEET INDEX <br />CODE REFERENCES <br />PROJECT <br />ADDRESS <br />1429 S GARNSEY ST, <br />SANTA ANA, CA 92707 <br />OWNER:ELVIS MARTINEZ <br />SCOPE: <br />HOUSE PHOTO <br />COVER SHEET <br />PHOTOVOLTAIC ROOF MOUNT SYSTEM <br />14 MODULES-ROOF MOUNTED - 5.670 KW DC, 5.700 KW AC AND 5.150 KW CEC AC <br />1429 S GARNSEY ST, SANTA ANA, CA 92707 <br />PV-1 COVER SHEET <br />PV-2 PLOT PLAN WITH ROOF PLAN <br />PV-3 ROOF PLAN & MODULES <br />PV-4 ELECTRICAL PLAN <br />PV-4A ELEVATION PLAN <br />PV-5 ATTACHMENT DETAIL <br />PV-6 ELECTRICAL LINE DIAGRAM <br />PV-7 WIRING CALCULATION <br />PV-7.1 LOAD CALCULATION <br />PV-8 LABELS <br />PV-9 PLACARD <br />PV-10 OPTIMIZER CHART <br />PV-11+EQUIPMENT SPECIFICATIONS <br />PV-1 <br />DESIGNER:ESR <br />PARCEL ID:01313207 <br />PROJECT TO COMPLY WITH THE FOLLOWING: <br />2022 CALIFORNIA BUILDING CODE (CBC) <br />2022 CALIFORNIA GREEN BUILDING CODE (CGBC) <br />2022 CALIFORNIA ENERGY CONSERVATION CODE(CEC) <br />2022 CALIFORNIA RESIDENTIAL CODE(CRC) <br />2022 CALIFORNIA FIRE CODE (CFC) <br />ASCE 7-16 <br />AUTHORITIES HAVING JURISDICTION: <br />BUILDING: CITY OF SANTA ANA <br />ZONING: CITY OF SANTA ANA <br />UTILITY: SCE <br />1. ALL COMPONENTS ARE UL LISTED AND CEC CERTIFIED, WHERE WARRANTED. <br />2. THE SOLAR PV SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH ARTICLE 690 OF THE CEC 2022. <br />3. THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL <br />OPERATION. <br />4. ALL CONDUCTORS OF A CIRCUIT, INCLUDING THE EGC, MUST BE INSTALLED IN THE SAME RACEWAY, OR CABLE, OR <br />OTHERWISE RUN WITH THE PV ARRAY CIRCUIT CONDUCTORS WHEN THEY LEAVE THE VICINITY OF THE PV ARRAY. <br />5. WHERE METALLIC CONDUIT CONTAINING DC CONDUCTORS IS USED INSIDE THE BUILDING, IT SHALL BE IDENTIFIED AS <br />"CAUTION: SOLAR CIRCUIT" EVERY 10FT. <br />6. HEIGHT OF THE AC DISCONNECT SHALL NOT EXCEED 6'-7" PER CEC CODE 240.24. <br />7. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH CEC 2022 690.47 AND 250.50 THROUGH 60 AND 250-166 SHALL BE <br />PROVIDED. PER CEC GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO THE SERVICE <br />ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE OR INADEQUATE A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED <br />AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT. GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE <br />CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO LARGER THAN #6 AWG COPPER AND BONDED TO THE EXISTING <br />GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. <br />8. PHOTOVOLTAIC MODULES ARE TO BE CONSIDERED NON-COMBUSTIBLE. <br />9. PHOTOVOLTAIC INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING. MECHANICAL, OR BUILDING ROOF VENTS. <br />10. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE. <br />WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF THE ROOF SURFACE. <br />11. ALL SINAGE TO BE PLACED IN ACCORDANCE WITH THE LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV <br />RESISTANT. ALL PLAQUES AND SINAGE WILL BE INSTALLED AS REQUIRED BY THE CEC AND AHJ. <br />12. INVERTER(S) USED IN UNGROUNDED SYSTEM SHALL BE UL 1741 LISTED. <br />13. THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE PERFORMED ONLY BY <br />QUALIFIED PERSONS [CEC 690.4(C)] <br />14. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED (OR BETTER), INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND <br />SWITCHES. <br />15. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH CEC ARTICLE 250. <br />16. SYSTEM GROUNDING SHALL BE IN ACCORDANCE WITH CEC 690.41. <br />17. PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION IN ACCORDANCE WITH <br />CEC 690.12 <br />18. DISCONNECTING MEANS SHALL BE LOCATED IN A VISIBLE, READILY ACCESSIBLE LOCATION WITHIN THE PV SYSTEM <br />EQUIPMENT OR A MAXIMUM OF 10 FEET AWAY FROM THE SYSTEM [CEC 690.13(A)] <br />19. ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH CEC 690.31 <br />20. WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER CEC 110.26(A)(1), 110.26(A)(2) AND 110.26(A)(3). <br />21. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED & IDENTIFIED IN ACCORDANCE WITH <br />UL1703 <br />22. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS REQUIRED PER CEC. <br />5.670 KW DC ROOF MOUNT <br />SOLAR PV SYSTEM WITH <br />14 JA SOLAR: JAM54S31 405/MR <br />405W MONO MODULES WITH <br />14 SOLAREDGE:S440-5NC4ARS POWER <br />OPTIMIZERS WITH <br />02 SOLAREDGE TECHNOLOGIES LTD. <br />SE5700H-USMNBL75 (240V) INVERTER <br />02 SOLAREDGE TECHNOLOGIES LTD. <br />ENERGY BANK 10 KWH BATTERY <br />BAT-10K1P WITH UPGRADE METER MAIN <br />COMBO TO 200A RATED BUS WITH <br />200A MAIN BREAKER <br />EXP 3/31/2026 <br />Jeffrey <br />Onorati <br />Digitally signed by <br />Jeffrey Onorati <br />Date: 2025.06.09 <br />11:26:47 -07'00' <br />The scope of the plans is for the installation of the solar photovoltaic system only <br />and the approval is subject to compliance with all applicable city and state codes <br />and regulations regarding construction. The approval of the plans does not <br />constitute any certification of the accuracy, completeness, or building permit status <br />of the existing buildings and structures as shown. <br />Bldg# 101124146 <br />Elec# 20186228 <br />Approval: <br />Elec - MSmith