Laserfiche WebLink
Summary of Scope of Work <br />Background <br />The City of Santa Ana is pursuing a number of lighting retrofits at several of their facilities. This <br />documeAt focuses on the proposed lighting fixture and controls scope of work for the Police <br />Department Administration Building. The Police Department Administration is a large Office <br />188,136 square foot facility that is city owned and operated. <br />The facility has a 24/1 operating profile with variable occupancy depending on the space, <br />creating an opportunity for significant energy savings. In addition to the interior lighting <br />upgrade, exterior shoe box fixture replacements are included in this scope. Detailed area by area <br />fixture counts are provided in the following: <br />• Appendix A: Police Department Lighting Inventory <br />Santa Ana Police Department <br />The following items and requirements should be clearly listed in any provided contractor bid: <br />MANDATORYSCOPE-LED Fixtures and Controls Product Requirements <br />All LED products and controls used in this project shall meet the following requirements: <br />a) Please refer to Appendix A below for an area by area breakdown of lighting equipment. <br />Contractor is responsible for verifying all Appendix A information before ordering or <br />installing equipment. <br />b) All LED fixtures shall be found on the current DLC qualified product list. All LED lamps <br />shall be found on the Energy Star product list. <br />c) All interior retrofit spaces will be fully Title 24 lighting power density (LPD) and <br />controls compliant. Including but not limited to, occupancy sensors, daylight harvesting, <br />and tuning controls. The lighting controls for the mandatory scope shall be stand alone. <br />d) Interior LED Fixtures shall have correlated color temperatures (CCT) of 3000K to 4000K <br />and attempt to match existing scheme. LED Lamps shall be handled in the same way. <br />e) All fixture replacements (and retrofit kit applications) will be like for like. With the <br />following exceptions, the indirect pendant (primarily in open office space) fixtures and <br />indirect/direct pendant fixtures will be replaced with pendant direct fixtures. <br />f) This lighting upgrade is primarily a 1 for 1 replacement. However, the contractor is <br />responsible for ensuring final layouts, configuration, and lighting performance meets the <br />city's needs. <br />g) All proposed fixtures shall be capable of dimming with a 0-10V signal. <br />25B-32 <br />