Laserfiche WebLink
SCALE: 1/16" <br />SITE PLAN <br />N <br />50 ft <br />1 4 5 .7 5 f t <br />50.01 ft <br />1 4 4 .9 4 f t <br />NOTE: "THE DISCHARGE OF POLLUTANTS TO ANY STORM <br />DRAINAGE SYSTEM IS PROHIBITED. SO SOLID WASTE, <br />PETROLEUM BYPRODUCTS, SOIL PARTICULATE, <br />CONSTRUCTION WASTE MATERIALS, OR WASTEWATER <br />GENERATED ON CONSTRUCTION SITES OR BY <br />CONSTRUCTION ACTIVITIES SHALL BE PLACED, <br />CONVEYED OR DISCHARGED INTO THE STREET, GUTTER <br />OR STORM DRAIN SYSTEM" <br />GENERAL NOTES <br />THE PLAN WILL CONFORM TO CALIFORNIA BUILDING CODE (CBC). THE 2016 CA. MECHANICAL CODE, 2016 CA. PLUMBING CODE, 2016 CA ELECTRICAL CODE, 2016 <br />CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBS), 2016 CALIFORNIA ENERGY EFFICIENCY STANDARDS (CEES) & CITY OF SANTA ANA REGULATIONS AND <br />ORDINANCES. <br />SMOKE DETECTORS TO BE INSTALLED PER SEC. 907.2.10 <br />DIMENSIONS AND NOTES SHALL TAKE PRECEDENCE OVER THE SCALING OF DRAWINGS. <br />WALL DIMENSIONS ARE TO THE EXTERIOR OF FRAMING UNLESS NOTED OTHERWISE. <br />LUMBER COMING IN CONTACT WITH CONCRETE OR MASONRY SHALL BE TREATED TO A MINIMUM OF 40.CCA. ALL LUMBER IN CONTINUOUS CONTACT WITH THE <br />GROUND SHALL BE TREATED TO A MINIMUM OF .60 CCA. <br />ALL FRAMING LUMBER TO BE #2 OR BETTER DF OR EQUIVALENT, UNLESS NOTED OTHERWISE. <br />EXTERIOR AND INTERIOR MATERIALS AND FINISHES TO BE DETERMINED BY OWNER. <br />STREET NUMBER SHALL BE VISIBLE FROM STREET ABOVE GARAGE DOOR ON LEFT SIDE <br />FIRE SPRINKLERS, SMOKE & CARBON MONOXIDE ALARMS <br />ALL NEW CONSTRUCTION, INTERIOR OR EXTERIOR ALTERATIONS, REPAIRS, OR ADDITION REQUIRING A PERMIT AND HAVING A VALUATION IN EXCESS OF $1000, <br />OR WHEN ONE OR MORE SLEEPING ROOMS ARE ADDED OR CREATED, THE ENTIRE DWELLING SHALL BE PROVIDED WITH DETECTORS LOCATED A REQUIRED FOR <br />A NEW DWELLING. SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS: (R314) <br />A.IN EACH SLEEPING ROOM. <br />B.OUTSIDE EACH SEPARATE SLEEPING AREA IN THE VICINITY OF THE BEDROOMS. <br />C.IN EACH STORY, INCLUDING BASEMAENTS AND HABITABLE ATTICS. <br />D.WHEN ONE OR MORE SMOKE ALARM IS REQUIRED THE ALARM DEVICE SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF <br />ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. <br />EXCEPTION: INTERCONNECTION IS NOT REQUIRED IN EXISTING DWELLING UNITS WHERE REPAIRS DO NOT RESULT IN THE REMOVAL OF WALL AND <br />CEILING FINISHES, THERE IS NO MEANS OF ATTIC, BASEMENT OR CRAWLSPACE AND NO PREVIOUS METHOD FOR INTERCONNECTION EXISTED. <br />ALL NEW CONSTRUCTION, INTERIOR OR EXTERIOR ALTERATIONS, REPAIRS, OR ADDITION REQUIRING A PERMIT AND HAVING A VALUATION IN EXCESS OF $1000, <br />AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED IN DWELLING UNITS AND IN SLEEPING UNITS WITHIN WHICH FUEL BURNING APPLIANCES ARE <br />INSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES IN ACCORDANCE WITH R315.1. CARBON MONOXIDE ALARMS SHALL ONLY BE REQUIRED IN <br />SPECIFIC DWELLING UNITS OR SLEEPING UNITS FOR WHICH THE PERMIT WAS OBTAINED. THE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS: <br />A.OUTSIDE EACH SEPARATE DWELLING UNIT SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOM(S). <br />B.ON EVERY LEVEL OF A DWELLING UNIT INCLUDING BASEMENTS. <br />C.WHERE MORE THAN ONE ALARM IS REQUIRED TO BE INSTALLED WITHING THE DWELLING UNIT OR WITHIN A SLEEPING UNIT THE ALARM SHALL BE <br />INTERCONNECTED IN A MANNER THAT ACTIVATION OF ONE ALARM SHALL ACTIVATE ALL THE ALARMS IN THE INDIVIDUAL UNIT. <br />EXCEPTION: INTERCONNECTION IS NOT REQUIRED IN EXISTING DWELLING UNITS WHERE REPAIRS DO NOT RESULT IN THE REMOVAL OF WALL AND <br />CEILING FINISHES, THERE IS NO MEANS OF ATTIC, BASEMENT OR CRAWLSPACE AND NO PREVIOUS METHOD FOR INTERCONNECTION EXISTED. <br />FIRE-RESISTANT CONSTRUCTION <br />OPENINGS AND PENETRATIONS THROUGH THE WALLS AND CEILING SEPARATING THE DWELLING FROM THE GARAGE SHALL BE IN ACCORDANCE WITH R302.5.2 <br />THROUGH R302.5.3: <br />A.GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED FROM THE ROOMS ABOVE BY A MINIMUM OF 5/8-INCH TYPE X GYPSUM BOARD <br />APPLIED TO THE GARAGE SIDE, WALLS AND CEILING. <br />B.OPENINGS SHALL BE EQUIPPED WITH SOLID WOOD DOORS OR SOLID OR HONEYCOMBED CORE STELL DOOR NOT LESS 1-3/8 INCHES THICK <br />DOOR OR 20-MINUTE FIRE-RATED DOORS. DOORS SHALL BE SELF-CLOSING AND SELF-LATCHING. WHERE THE GARAGE IS PROTECTED <br />BY AN AUTOMATIC RESIDENTIAL FIRE SPRINKLER SYSTEM, THE DOORS NEED ONLY BE SELF-CLOSING AND SELF-LATCHING. <br />LIGHT, VENTILATION & HEATING <br />UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, FANS MUST BE CONTROLLED BY A HUMIDISTAT WHICH SHALL BE READILY <br />ACCESSIBLE. HUMIDISTAT CONTROLS SHALL BE CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE OF 50 TO 80 PERCENT. <br />EMERGENCY EGRESS <br />BASEMENTS, HABITABLE ATTICS AND SLEEPNG ROOMS SHALL HAVE AT LEAST ONE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING. (R310.1) <br />A.MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET. <br />B.MINIMUM 5 SQUARE FEET FOR GRADE-FLOOR OPENINGS. <br />C.MINIMUM NET CLEAR OPENING WIDTH OF 20 INCHES. <br />D.MINIMUM NET CLEAR HEIGHT OF 24 INCHES. <br />E.SILL HEIGHT OF NOT MORE THAN 44 INCHES ABOVE THE FLOOR. <br />MEANS OF EGRESS <br />PROVIDE MINIMUM 42" HIGH GUARDS ALONG OPEN-SIDED WALKING SURFACES, STAIRS, RAMPS AND LANDINGS THAT ARE LOCATED MORE THAN 30 INCHES <br />ABOVE THE FLOOR OR GRADE BELOW. GUARD OPENINGS SHALL BE LESS THAN 4" (4-3/8" FOR STAIRS). <br />CONSTRUCTION <br />EXTERIOR LATH: PROVIDE TWO LAYERS OF GRADE D PAPER OVER ALL WOOD BASE SHEATHING. (R703.6.3) <br />WEEP SCREED FOR STUCCO AT THE FOUNDATION PLATE LINE A MINIMUM OF 4 INCHES ABOVE EARTH OR 2 INCHES ABOVE PAVED AREAS. (R703.6.2.1) <br />ATTACH A COPY OF ICC REPORT OR REPORT BY OTHER APPROVING AGENCY TO DRAWINGS FOR: <br />A.ICC LISTED ROOFING MATERIALS <br />PLUMBING, MECHANICAL & ELECTRICAL <br />ADDITIONS AND REMODELS REQUIRE ELECTRICAL LOAD CALCULATIONS FOR THE EXISTING PANEL IF THE EXISTING ELECTRICAL PANEL IS UNDER 200 AMPS. (FV) <br />SHOW LOCATION OF THE G.F.C.I. PROTECTION TO ALL 125 VOLT, 15 AND 20 AMP RECEPTACLES INSTALLED IN BATHROOMS, GARAGES, OUTDOORS, <br />CRAWLSPACES, UNFINISHED BASEMENTS, KITCHEN COUNTERTOP SURFACE AND WITHIN 6 FEET OF LAUNDRY, UTILITY AND WET BAR SINKS. (CEC 210.8(A)) <br />EXCEPTION: SINGLE OUTLET RECEPTACLES IN GARAGES UTILIZED FOR A FIXED OR STATIONARY APPLIANCE. <br />ALL 120-VOLT, SINGLE PHASE, 15 AND 20 AMPERE BRANCH CIRCUITS IN FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, <br />SUNROOMS, RECREATIONS ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER, <br />COMBINATION-TYPE. (CEC 210.12) <br />WATER HEATERS SHALL BE ANCHORED OR STRAPPED TO THE STRUCTURE. PROVIDE 1-1/2" x 16 GAUGE STRAPS AT TOP AND BOTTOM WITH 3/8"D x 3" LONG LAG <br />BOLT AT EACH END. DETAIL COMBUSTION AIR REQUIREMENTS. (CPC 508.2) <br />ROOF <br />VAULTED CEILINGS - EACH ENCLOSED RAFTER SPACE BETWEEN FRAMING MEMBERS WILL BE VENTILATED AT THE EAVE AND THE TOP OF THE ROOF RIDGE. <br />VICINITY MAP <br />EXISTING LIVING SPACE:1534 SQ. FT. <br />EXISTING GARAGE: 462 SQ. FT. <br />EXISTING TOTAL LIVING AND GARAGE:1996 SQ. FT. <br />PROPOSED LIVING SPACE: 1733 SQ. FT. <br />PROPOSED GARAGE: 462 SQ. FT. <br />PROPOSED TOTAL LIVING AND GARAGE:2195 SQ. FT. <br />TOTAL LOT SQUARE FOOTAGE:7250 SQ. FT. <br />OWNER & BUILDER'S NOTE <br />THESE PLANS SHALL NOT BE USED FOR CONSTRUCTION UNTIL STAMPED AND SIGNED BY AN <br />ENGINEER AND APPROVED BY THE LOCAL BUILDING DEPARTMENT. THE BUILDER IS <br />EXPECTED TO FOLLOW THESE PLANS, APPLICABLE BUILDING CODES AND LOCAL <br />ORDINANCES. HE SHALL VERITY THAT SITE CONDITIONS ARE CONSISTENT WITH THESE <br />PLANS BEFORE STARTING WORK. WHILE THESE PLANS ARE DRAWN TO SHOW THE <br />PROPOSED WORK AS ACCURATELY AS POSSIBLE, SCHEMATIC DETAILS MAY BE USED IN <br />SOME CASES FOR CLARITY. WORK NOT SPECIFICALLY DETAILED SHALL BE CONSTRUCTED <br />TO THE SAME QUALITY AS SIMILAR WORK THAT IS DETAILED. <br />WRITTEN DIMENSIONS AND SPECIFIC NOTES SHALL TAKE PRECEDENCE OVER SCALED <br />DIMENSIONS AND GENERAL NOTES. THE ENGINEER/DESIGNER SHALL BE CONSULTED FOR <br />CLARIFICATION IF SITE CONDITIONS ARE ENCOUNTERED THAT ARE DIFFERENT THAN <br />SHOWN, IF DISCREPANCIES ARE FOUND IN THE PLANS OR NOTES, OR IF A QUESTION ARISES <br />OVER THE INTENT OF THE PLANS OR NOTES. <br />THE ENGINEER/DESIGNER ASSUMES NO RESPONSIBILITY FOR SCHEDULING, FABRICATION, <br />CONSTRUCTION TECHNIQUES OR MATERIALS, OR QUANTITIES USED IN THE WORK. THE <br />ENGINEER/ DESIGNER ASSUMES NO RESPONSIBILITY FOR FIELD CHANGES, SITE VARIANCES <br />OR DISCREPANCIES NOT BROUGHT TO HIS/HER ATTENTION FOR CLARIFICATION. <br />OWNER: <br /> Mike Bishop <br />PROJECT ADDRESS: <br />2424 N. Valencia St. <br />Santa Ana, CA 92706 <br /> <br />JURISDICTION ORANGE COUNTY <br />ZONING: R1 (SINGLE FAMILY RESIDENCE) <br />OCCUPANCY:R3 <br />TRACT #: 1258 <br />LOT #: 2 <br />APN#:003-071-02 <br />TYPE OF <br />CONSTRUCTION V-B <br />PERMIT #: <br />THE INFORMATION SHOWN ON THIS <br />SITE PLAN WAS PROVIDED BY CITY <br />RECORDS. FIELD SURVEY OR <br />VERIFICATION WAS NOT MADE. <br />SQUARE FOOTAGE: <br />2 3 5 5 2 V i a P a l o m a S u i t e B <br />C o t o D e C a z a , C A 9 2 6 7 9 <br />P h o n e : (9 4 9 ) 7 6 6 -1 4 1 0 <br />F A X : (9 4 9 ) 7 6 6 -1 4 0 9 <br />t o d d c u s t o m h o m e s @ c o x .n e t <br />L i c . #6 3 5 8 0 5 <br />B i s h o p R e s i d e n c e R e m o d e l <br />D R A W N B Y : D .W <br />. <br />N o v 1 2 , 2 0 1 8 <br />S C A L E : S E E V I E W <br />A 1 <br />S H E E T N U M B E R <br />SHT CONTENTS <br />SHEET DIRECTORY <br />A1 <br />A2 <br />A3 <br />A4 <br />A5 <br />A6 <br />PROJECT NOTES - SITE PLAN <br />EXISTING FLOOR PLAN <br />EXISTING ELEVATIONS <br />PROPOSED FLOOR PLAN <br />PROPOSED ELEVATION <br />ROOF PLAN <br />2 4 2 4 N . V a l e n c i a S t . <br />S a n t a A n a , C A 9 2 7 0 6 <br />P R O J E C T N O T E S <br />S I T E P L A N <br />SCOPE OF WORK <br />NEW ADDITION OF MASTER BEDROOM AND GUEST BEDROOM APPROXIMATELY 199 SQ. FT. PER PLAN <br />NEW MASTER BATHROOM PER PLAN <br />REMODEL OF EXISTING GUEST BATHROOM AND KITCHEN REMODEL PER PLANS <br />NOTES: <br />·NEW PLUMBING FIXTURES TO MEET CITY AND STATE CODES. <br />·ELECTRICAL TO MEET CITY AND STATE CODES. <br />·NEW ADDITION STUCCO AND MATERIALS TO MATCH EXISTING. <br />·NEW ROOF SLOPE AND MATERIALS TO MATCH EXISTING. <br />NOTES <br />VALENCIA ST. <br />7' <br />9' <br />41 <br />. <br />5 <br />' <br />8' <br />1.5' <br />42 <br />' <br />NEW ADDITION <br />3-29