My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
80A - JOINT WORK CENTER MOU
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2019
>
05/07/2019
>
80A - JOINT WORK CENTER MOU
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2022 11:33:23 AM
Creation date
5/2/2019 6:11:42 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Community Development
Item #
80A
Date
5/7/2019
Destruction Year
2024
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
722
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXHIBIT 1C <br />Seismic Certificate of Applicable Code <br />I am a State or California licensed structural engineer, civil engineer or architect and certify that the building <br />located at; 801 Civic Center Drive, Santa Ana, CA 92701, was reviewed by me. This certiflcatlon was either <br />prepared by me or the bulk of work was performed under my direct supervision. I have no ownership interest <br />In the subject property. <br />A Certificate of Applicable Code may be provided If the entire building was Constructed under a permit <br />approved by the focal jurisdiction and was designed to meet one of the following requirements; <br />©l998 or subsequent editions of the California Building Code; or, <br />X 1976 or subsequent editions of the Uniform Building Code and the building does not have any <br />one of the enumerated characteristics or conditions listed below: <br />• Unrefnforoed masonry elements, whether load -bearing or not; not Including brick veneer; <br />• Precast, prestressed, orpost-tensloned structural or architectural elements, except piles; <br />• Flexible diaphragm (e.g., plywood) -shear wall (masonry or concrete) structural system <br />constructed pursuant to editions of the Uniform Building Code prior to the 1997 edition; <br />• Apparent additions, alterations, or repairs to the structural system made without a building <br />permit; <br />• Constructed on a site with a slope with one or more stories ap rtiall below grade (taken as <br />50% or less) for a portion of their exterior; <br />• Soft or weak story, Including wood frame structures with cripple walls, or is construction over <br />first -story parking; <br />• Seismic retreflt of the building, whether voluntary or mandated, whether partial or complete; <br />• Repairs following an earthquake; <br />• Welded steel moment frames (WSMF) that constitute the primary seismic force -resisting <br />system for the building, and the structure was designed to code requirements preceding <br />those of the 1097 edition of the Uniform Buiiding Code, and the building site has experienced <br />an earthquake of sufficient magnitude and site peak ground motions that inspection is <br />required when any of the conditions of Section 3.2 of FEMA 352 Indicate an investigation of <br />beam -column connections Is warranted; <br />• Visible signs of distress or deterioration of structural or non-structural systems, e.g„ <br />excessively cracked and/or spelling concrete walls or foundations, wood dry rot, etc. <br />Documentation of the selected performance level evaluation will be retained by the preparer and shall be <br />available to the State upon request. <br />Name: Ryan Blshoff <br />Firm: Brandow 8, Johnston, Inc. <br />Telephone No: 949.962.8610 <br />License No: SE 6250 <br />License Expiration Date; 08130/17 <br />��� ( 11/14/2016 <br />Signature // pate <br />wummenr: ---- <br />For a building not qualifying under the above criteria; an Independent Review must be performed. <br />RELPS Optfan 2 <br />30 Apnl 00 <br />80A-290 <br />
The URL can be used to link to this page
Your browser does not support the video tag.