Laserfiche WebLink
EXHIBIT 1E <br />Seismic Certificate of Applicable Code <br />I am a Stele of Californla licensed structural angineer, civil engineer Orarchitect and certify that the building <br />located al; 801 Civic Center Drive, Santa Ana, CA 92701, was reviewed by me. This certification was either <br />prepared by me or the bulk of work was performed under my direct supervision, 1 have no ownefshlp Interest <br />In the subject property. <br />A Certificate of Applicable Code may be provided If the entire building was constructed under a permit <br />approved by the local jurisdiction and was designed to meet one of the following requirements: <br />©l998 or subsequent editions of the California Building Code; or, <br />X 1976 or subsequent editions of the Uniform Building Code and the building does not have any <br />one of the enumerated characteristics or conditions listed below: <br />• Unrelnforced masonry elements, whether load -bearing or not; not including brick veneer; <br />• Precast, prestressed, orpost-tensioned structural or architectural elements, except piles; <br />• Flexible diaphragm (e.g., plywood) -shear wall (masonry or concrete) structural system <br />constructed pursuant to editions of the Uniform Building Code prior to the 1997 edition; <br />• Apparent additions, alterations, or repairs to the structural system made without a building <br />permit; <br />• Constructed on a site with a slope with one or more stories ap Nally below grade (taken as <br />50% or less) for a portion of their exterior; <br />• Soft or weak story, Including wood frame structures with cripple walls, or is construction over <br />first -story parking; <br />• Seismic retrofit of the building, whether voluntary or mandated, whether partial or complete; <br />• Repairs following an earthquake; <br />• Welded steel moment frames (WSMF) that constitute the primary seismic force -resisting <br />system for the building, and the structure was designed to code requirements preceding <br />those of the.1097 edition of the Uniform Building Code, end the building site has experienced <br />an earthquake of sufficient magnitude end site peak ground motions that inspection Is <br />required when any of the conditions of Section 3,2 of FEMA 352 indicate an investigation of <br />beam -column connections Is warranted; <br />• Visible signs of distress or deterioration of structural or non-structural systems, e.g,, <br />excessively cracked andlor spelling concrete wells or foundations, wood dry rot, etc, <br />Documentation of the selected performance level evaluation will be retained by the preparer and shall be <br />available to the State upon request, <br />Name: Ryan Bishoff <br />Firm: Srandow &, Johnston, Inc. <br />Telephone Nc: 949.662.8610 <br />License No: SE 0250 <br />License Expiration pate; 06130117 <br />11 /14/2016 <br />Signature pate <br />Comment: For a building not qualifying under the above criteria; an Independent Review must be performed. <br />KELPS Option 2 <br />30 Apd; 00 <br />80A-479 <br />