My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
80A - JOINT WORK CENTER MOU
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2019
>
05/07/2019
>
80A - JOINT WORK CENTER MOU
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2022 11:33:23 AM
Creation date
5/2/2019 6:11:42 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Community Development
Item #
80A
Date
5/7/2019
Destruction Year
2024
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
722
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXHIBIT 3 <br />EXHIBIT B — OUTLINE SPECIFICATIONS <br />DIVISION 2 <br />B. Exterior signs (applicable only if building is totally occupied by the State): Lessor shall <br />provide and install exterior signs. Letters shall be of cast aluminum alloy, bronze, black <br />anodized finish or dimensional plastic. Submit samples to DGS for approval. The <br />words "STATE OF CALIFORNIA" and the name of the occupying department, and <br />street address shall be in scale with the building elevation. <br />a) Lessor shall be solely responsible for any additional permits and fees. <br />F. Assistive listening devices: <br />1. Lessor shall provide an assistive listening device system for all meeting, conference, <br />quiet, assembly, and gathering rooms. The system shall comply with all accessibility <br />requirements. <br />Occupant load less than 50: <br />a) One portable system per floor can be shared between rooms with occupant loads <br />less than 50. The system shall be designed to accommodate the largest room size <br />that is being shared. The portable, wireless FM -based system shall include high <br />output acoustic headset(s) such as the Centrum Motive PFM 360 (or current <br />model) with disposable ear plugs, neck-loop(s), conference microphones and a <br />lockable chargerlaccessory carry case large enough to hold all equipment. The <br />system shall be hearing aid compatible. Lessor shall provide signage at reception <br />area indicating that the device is available. <br />Occupant load of 50 or more: <br />b) Rooms with more than a 50-person occupant load and fixed seating must have a <br />fixed assistive listing device system for 4 percent of the total number of seats in <br />these rooms, but not less than two seats. Lessor shall provide signage inside <br />each room and in the common hallway and/or corridor indicating that the device is <br />available. <br />G. Modular systems furniture (MSF): <br />1. The State may elect to furnish and install MSF in lieu of traditional office furniture. <br />MSF may be comprised of any combination of freestanding partition panels, panel - <br />supported work surfaces, files, components, and access raceways. <br />Where the State elects to install MSF as described above, Lessor, at Lessor's sole <br />cost and expense, shall perform the following: <br />c) Obtain any required permits from the local jurisdiction. <br />d) Provide electrical engineering and installation of all wiring systems and <br />components as necessary or required from the building's electrical system to the <br />MSF for a complete and fully operational system, <br />e) Provide a minimum of four 20-amp circuits to each base feed and/or power pole <br />feed. Each base feed or power pole shall serve a maximum of four workstations. <br />f) Coordinate electrical junction box locations with State -furnished MSF plans. See <br />Division 3 Special Provisions for MSF wiring diagram. <br />g) Install voice and data communication cabling from the data communication closet <br />to the final point of termination at the MSF panel. <br />h) Cut and assemble the supplied power pole to the appropriate length, insert pole <br />into top trim of panel, align the pole true and plumb, seismically brace pole, cutting <br />the correct size hole in the ceiling tile, routing the electrical and data conduit <br />22 <br />Rev. March 2019 <br />80A-632 <br />
The URL can be used to link to this page
Your browser does not support the video tag.