EXHIBIT 1A
<br />SEISMIC SCREENING CHECKLIST Reviewer Name
<br />Project Nti^'. Total Bldg, Sq, Ft.
<br />Agehc� > Total Laase Sq. Ff.,
<br />L6Cat10r1,,,,,
<br />Hours of Use
<br />1 Retrofit Mnce 197 7 6 •
<br />No fudherscreening required if documentation of retrofit la provided.
<br />2 Ac
<br />Ty
<br />a of Building & '
<br />pe of Corrstructlon
<br />TIlf-Up
<br />Pre 1933
<br />6ar'r'Tli
<br />1933 to 1976
<br />_
<br />Post 1976
<br />�d?"e
<br />Score
<br />Masonr
<br />10
<br />6
<br />1
<br />Reinforced Concrete
<br />7
<br />5
<br />1
<br />Wood Frame
<br />3
<br />2
<br />1
<br />Steel
<br />7
<br />3
<br />1
<br />1
<br />Max• number of stories allowable for screening 1a 6. Assign one point
<br />per story, te„ 1 min., 6max. (1.6) 4
<br />Assign points as Indicated far counties as grouped in a, b, & c below
<br />(a) 12 points In Los Angeles, West 113 of San Bernardino, 12
<br />Contra Costa, Riverside, Santa Clare, Alameda, Ventura,
<br />Serf Francisco, Merin
<br />(b) 9 points In Sonoma, Santa Barbara, San Mateo, 9 9
<br />Orange, San Dlego, Inyo, San Luis Obispo, Napa, Kern,
<br />Monterey, Solano, Humboldt, Mendocino
<br />(c) 3 points to all other counties not listed above. 3
<br />fi:Conilau'raEio:n.fV.erEiGat}',i.4rir ,:';`;.'..-.',:,•::..,,- .,
<br />m®® sm®0 1
<br />/
<br />5 a 7 10 7 1 7
<br />All other configurations 1
<br />6 Configuration, (flan View),
<br />1 3 7 7 7
<br />7 Visible Defects
<br />Subjective scoring: 10 paints max, assignable for all defects
<br />observed. The fallowing list Is of typical things to look for.
<br />a Dry rot; look for water stains an ceiling tiles and wails
<br />b Damaged foundations; look for iarge cracks and misalignment
<br />c Sagging or shifted beams; look for bowing in center, check for
<br />position (parallel) relative to other members
<br />d Tilted walls or columns
<br />e Corrosion or steel; look for rust, flaking, eta Check for water stains.
<br />f Cracks greater then 1/6"in masonry or concrete
<br />g Check for any material that crumbles (wood, piaster, cone, etc) (1.10)
<br />TOTAL
<br />Total score of 20 or above requires standard seismic certification.