Laserfiche WebLink
DIVISION 4 — REFERENCE FORMS <br />5. FIRE PROTECTION SYSTEMS <br />• FIREALARM <br />❑ Provide highlighted set of data sheets <br />❑ Provide cut sheets for all components <br />❑ Provide current CSFM listings <br />Provide/correct equipment matrix <br />❑ Provide a sequence of operation Identify <br />approved monitoring station <br />❑ Identify fire alarm and egress -control <br />devices <br />❑ Demonstrate compliance for egress -control <br />systems <br />❑ Provide ceiling configuration, surface, and <br />height <br />❑ Provide/correct voltage`drop calculations for <br />devices <br />❑ Provide/correct riser diagram <br />❑ Provide/correct'standby,battery calculations <br />❑ Demonstrate audible vr'sual notification <br />❑ Demonstrate manual fire alarm box coverage <br />• FIRE PRINKLERS <br />❑ Provide all OSFM shop drawing, notes <br />❑ Submittal shall comply with OSFM design <br />guideline <br />❑ Identify system type (wet, dry, pre -action, <br />etc:) <br />❑ provide ceiling configuration, surface, and <br />height " <br />❑ Provide hydraulic calculations <br />❑ Provide full height cross sections/ceiling <br />construction <br />❑ Identify area protected:by.each system for. <br />each floor <br />❑ Identify area limitations for hazard <br />classifications <br />❑ Correct notes/des ion to reflect CA <br />o Location and size of extinguishing agent <br />o Location of manual means of activation <br />o Location and identity of gas and electric <br />shutoffs <br />o Interconnection to building fire alarm system <br />o Location of a Class K fire extinguisher <br />7. ELECTRIC VEHICLE CHARGING STATIONS <br />Identify required signage, posts, wheel stops <br />❑ Identify electrical panel bonding and <br />grounding <br />❑ Provide location of disconnect <br />❑ Charging equipment for vehicles requiring <br />ventilation <br />❑ Identify means of indoor mechanical <br />ventilation <br />❑ Provide details for underground tuns. <br />❑ (Trench depths, conduit/conductor sizes) <br />8. HAZARDOUS MATERIALS <br />❑ Inventory summary with hazard class and <br />totals <br />❑ Safety Data Sheets <br />❑ -Floor plans <br />❑ Occupancy classifications <br />® Control areas <br />❑ Fire resistive construction <br />❑ Hazardous materials warning signs <br />❑ No smoking signs <br />❑ Hazardous materials alarm devices <br />❑ Hazardous materials cabinets Fume hoods <br />and enclosures <br />❑ Equipment utilizing hazardous materials <br />❑ ;Spill control/secondary containment <br />❑ Standby/emergency power` <br />9. HIGH PILE STORAGE <br />amendments <br />❑ <br />Letter of intent signed by authorized , <br />❑ Identify misdellaneous storage condition <br />❑ <br />department head <br />HPS analysis prepared by a'FPE <br />6. HOOD AND DUCT EQUIPMENT/SYSTEMS < <br />® <br />Scaled site plan (fire lanes;_ hydrants, FDC's, <br />❑ Scaled plan of area and,equipment <br />❑ Dimensions of hoods, ducts, and appliances <br />® <br />risers) <br />Scaled floor plan (HPS area, racks, access <br />13 Equipment list for system, devices and : <br />❑ <br />doors) <br />Fire sprinkler design density <br />materials <br />❑ Manufacturer's installation instructions <br />❑ <br />❑ <br />Aisle dimensions <br />Dimensions and location of flue spaces <br />❑ Cut sheets and compliance with UL 300 <br />Standard <br />El <br />Location of different commodity classes <br />❑ Isometric drawing piping and components <br />❑ <br />❑ <br />Location of banded/encapsulated storage <br />o Type, size and length of piping <br />length <br />Location and type of building columns <br />o Size and number fittings <br />❑ <br />Fire resistive construction <br />o Model number andd llocations of nozzles <br />❑ <br />Occupancy classification of adjacent tenants <br />o Location, temperature and model of <br />❑ <br />Location and design of smoke vents <br />detectors <br />�,,_# 1 (Rev-3/19) <br />