Laserfiche WebLink
T R A N S I T Z O N I N G C O D E : 4.0 - Architectural Standards <br />Division 4. <br />Architectural Standards/Building Types. <br />Sec.41-2020. Building Types, General Provisions. <br />(a) Each proposed building shall be designed in compliance with the standards of the <br />applicable building type. <br />(b) Subject to the requirements of the applicable zone, a proposed building shall be designed <br />as one of the building types permitted by the applicable zone by Table BT-1 entitled <br />Permitted Building Types. <br />Tower -on -Podium <br />OLive -Work <br />Table BT-1. Permtted Building Types <br />Building Type <br />Multi- <br />ramify <br />Mixed- <br />Use <br />[1] <br />Density <br />Range <br />[21 <br />Lot Depth <br />Lot Width <br />[31 <br />Stories <br />Building Types Allowed by Zone <br />min - max <br />min - max <br />max <br />TV <br />DT <br />UC <br />CDR <br />UN-2 <br />UN-1 <br />A.Tower-on-Podium <br />YES <br />YES <br />75-90 <br />200'min <br />200'-250' <br />25 <br />Y <br />- <br />- <br />- <br />- <br />- <br />B. Flex Block <br />YES <br />YES <br />30-40 <br />43e100'min <br />75'- <br />1 <br />Y <br />Y <br />Y <br />Y <br />- <br />- <br />C. Lined Block <br />YES <br />YES <br />45-50 <br />47e100'min <br />125'-300 <br />5u <br />Y <br />Y <br />Y <br />- <br />- <br />- <br />D.StackedDwellings <br />YES <br />YES <br />40-50 <br />43e 100'min <br />125-200' <br />6 <br />Y <br />Y <br />Y <br />- <br />- <br />- <br />E.HybridCourt <br />YES <br />YES <br />45-50 <br />160'-250' <br />150'-200' <br />5 <br />- <br />- <br />- <br />- <br />Y[51 <br />- <br />F. Courtyard Housing <br />YES <br />YES <br />20-30 <br />130'-250' <br />125'-200' <br />5 <br />Y <br />Y <br />Y <br />- <br />Y <br />- <br />G. Live/Work <br />NO <br />YES <br />12-15 <br />100'-200' <br />75-125' <br />3 <br />Y <br />Y <br />Y <br />Y <br />Y <br />Y <br />H. Rowhouse <br />YES <br />YES <br />7-18 <br />100'-200' <br />75-150' <br />3 <br />- <br />- <br />- <br />- <br />Y <br />- <br />I.Tuck-Under <br />YES <br />YES <br />12-18 <br />75'min <br />94'-250' <br />3 <br />Y <br />Y <br />Y <br />- <br />Y <br />- <br />J.BungalowCourt <br />YES <br />YES <br />10-15 <br />130'min <br />100'-180, <br />2 <br />- <br />- <br />- <br />- <br />Y <br />Y <br />K. Duplex/Triplex/ <br />Quadplex <br />YES <br />YES <br />10-15 <br />100'min <br />50'-125' <br />3 <br />- <br />- <br />- <br />- <br />Y <br />Y[61 <br />L. House <br />NO <br />YES <br />5-7 <br />100'min <br />40'-60' <br />2 <br />- <br />- <br />- <br />- <br />Y <br />Y <br />O <br />M. HOUSE L. DUPLEX, TRIPLE K. BUNGALOW <br />&QUADPLEX COURT <br />�ALK-UP ACCESS <br />I I <br />❑ �El <br />❑' ❑� EL <br />I ❑ Q <br />4 4I <br />Q Flex Block <br />© Rowhouse <br />Y = Permitted -= Not Permitted <br />[1] The degree of mixed use depends on the particular <br />zone in which the building is located. <br />[2}In dwelling units per acre(du/ac). Each type is sub- <br />ject to the maximum stories allowed in each zone <br />and the particular building size and massing require- <br />ments. <br />[3] Measured along the front property line of the lot <br />[4] This building type can be used on lots that have <br />resulted from a legal subdivision provided there is a <br />minimum frontage of 40 feet. <br />[5] Allowed on specific locations only. <br />not oermitted in the UN-1 zone. <br />[71 Line Block permitted to a maximum of 10-stories in <br />O <br />J. TUCK -UNDER <br />HOUSING <br />© <br />O <br />I. ROWHOUSE <br />H. LIVE \ <br />WORK <br />4:1 TRANSIT ZONING CODE <br />SPECIFIC DEVELOPMENT 84 <br />City of Santa Ana, California <br />