6 <br />of MERV 13 air filters in all mechanically supplied outdoor air ventilation systems. This <br />applies to both the residential and commercial portions of this development. <br /> <br /> <br />Indoor Air Quality Impact Mitigation Measures <br /> <br />The following are recommended mitigation measures to minimize the impacts upon indoor <br />quality: <br /> <br />- indoor formaldehyde concentrations <br />- outdoor air ventilation <br />- PM2.5 outdoor air concentrations <br /> <br />Indoor Formaldehyde Concentrations Mitigation. Use only composite wood materials (e.g. <br />hardwood plywood, medium density fiberboard, particleboard) for all interior finish <br />systems that are made with CARB approved no-added formaldehyde (NAF) resins or ultra- <br />low emitting formaldehyde (ULEF) resins (CARB, 2009). <br /> <br />Outdoor Air Ventilation Mitigation. Provide each habitable room with a continuous <br />mechanical supply of outdoor air that meets or exceeds the California 2016 Building Energy <br />Efficiency Standards (California Energy Commission, 2015) requirements of the greater of <br />15 cfm/occupant or 0.15 cfm/ft2 of floor area. Following installation of the system conduct <br />testing and balancing to insure that required amount of outdoor air is entering each habitable <br />room and provide a written report documenting the outdoor air flow rates. Do not use <br />exhaust only mechanical outdoor air systems, use only balanced outdoor air supply and <br />exhaust systems or outdoor air supply only systems. Provide a manual for the occupants <br />(residential and commercial), that describes the purpose of the mechanical outdoor air <br />system and the operation and maintenance requirements of the system. <br /> <br />PM2.5 Outdoor Air Concentration Mitigation. Install air filtration with a minimum efficiency <br />of MERV 13 to filter the outdoor air entering the mechanical outdoor air supply system. <br />Install the air filters in the system such that they are accessible for replacement by the
The URL can be used to link to this page
Your browser does not support the video tag.