Laserfiche WebLink
TRANSIT ZONING CODE <br />3:5 TRANSIT ZONING CODE <br />SPECIFIC DEVELOPMENT 84 <br />City of Santa Ana, California <br />Building Types Min Stories Max Stories <br />Tower-on-Podium not allowed not allowed <br />Flex Block 2 5 <br />Lined Block 2 5 <br />Stacked Dwellings 2 5 <br />Hybrid Court not allowed not allowed <br />Courtyard Housing 2 5 <br />Live-Work 2 3 <br />Rowhouse not allowed not allowed <br />Tuck-Under Housing 2 3 <br />Bungalow Court not allowed not allowed <br />Duplex/Triplex/ <br />Quadplex <br />not allowed not allowed <br />(a) Permitted building types and <br /> minimum and maximum height <br />Table UC-1, entitled Building Types and <br />Mimimum and Maximum Height identifies the <br />approved building types and the minimum <br />and maximum height that is permitted for each <br />building type within the UC zone subject to <br />compliance with all applicable standards. <br />Table UC-1. Building Types and Minimum and <br /> Maximum Height. <br />2b <br />2c <br />2a <br />FrontStreet Side Alley where occurs2e <br />2d <br />Setback Above Grade Subterranean <br />(2a) Front yard min 50% lot depth 5' min <br />(2b) Street side 5' min 5' min <br />(2c) Side yard 5' min 5' min <br />(2d) Rear yard 5' min 5' min <br />(2e) Alley yard 3' min 3' min <br />c. d. Parking setback standards. Table UC-6 identi- <br />fies the minimum setback standards for the <br />off-street parking. <br />Table UC-6. Parking Setback Standards. <br />(2) Off-street parking standards <br />a. Table UC-5 identifies the minimum off-street <br /> parking spaces that shall be provided. All frac- <br /> tions shall be rounded up to the next whole <br /> number. <br />Table UC-5. Off-Street Parking Standards. <br />Type Min Width Max Width <br />1-way 8'12' <br />2-way 20'25' [a] <br />Parking not permitted not permitted <br />(d) Parking. <br />(1) Driveway Standards. Table UC-4 identifies the <br /> minimum and maximum width of driveways and <br /> permitted parking on driveways. <br />Table UC-4. Driveway Standards <br />Table UC-2, entitled Building Setback Standards <br />identifies the minimum setbacks required and, <br />where noted, maximum setbacks permitted. The <br />setbacks shall apply to all stories of a building. <br />Table UC-2. Building Setback Standards. <br />[a] In situations where the existing sidewalk is 10 <br />feet or less in width, at the discretion of the <br />City of Santa Ana, a setback greater than iden- <br />tified in the above table may be required to <br />effectively result in a 10 foot wide sidewalk. <br />Setback Min.Max. <br />(1a)Front yard 0' [a]0' <br />(1b)Street Side 0' [a]10' <br />(1c)Side yard 0'No reqmt <br />(1d)Rear yard 15'No reqmt <br />(b) Building Setbacks. <br />(1) Outdoor dining - Such encroachments per <br />approval of PBA and PWA Directors, separate <br />permit and agreement. <br />(2) Encroachments. Awnings, Signage, Balconies, <br />Bay windows and Frontage Types may encroach <br />into the required setback subject to the <br />standards indentified in Table UC-7, entitled <br />Encroachments. <br />Table UC-7. Encroachments <br />Encroachment Vertical Horizontal <br />(2a)except awnings min 8' clear max 18" <br />(2b)except awnings min 12' <br />clear <br />max 24" <br />(2c)awnings min <br />10'clear <br />within 2' <br />of curb <br />Side yard N/A 0' <br />Rear yard to eave [1]5' <br />Alley yard to eave [1]3' <br />[1] Eave allowed to 3' of property line. <br />(e) Encroachments <br />a <br />Allowable <br />Encroachment per <br />table below <br />R.O.W.Property Line <br />Min 2' clear of curbCURB <br />Setback Line <br />2b <br />2c 2c <br />2a,b <br />Frontage Types <br />Permitted <br />% of frontage <br />Shopfront min 65 <br />Forecourt max 50; remainder of <br />frontage per allowed <br />types <br />Stoop max 50 <br />Frontyard/Porch max 100 <br />(c) Frontage Requirements. <br />a <br />R.O.W.Property Line <br />Setback Line1a <br />2a <br />if parcel has side <br />street frontage <br />Frontage <br />height and <br />other require- <br />ments per <br />Section 4.2 <br />: Urban Standards - Zone Requirements <br />1a <br />1b <br />1c <br />1e <br />1e <br />1d <br />FrontStreet Side Alley where occurssee encroachments <br />see encroachments <br />Parking Permitted <br />Section 41-2012. Urban Center (UC) <br />b. The parking requirements found in Table UC-5 <br /> shall apply only to new buildings, additional <br /> building area on existing buildings or con- <br /> version of existing building area to a new use. <br /> Conversion of building area of an historically <br /> designated building to a new use, where the <br /> building envelope is not increased in size shall <br /> have no parking requirement until such time as <br /> the City determines that 95 percent capacity on <br /> the five existing City controlled parking struc- <br /> tures in the downtown has been reached. <br />c. Vehicular access to the off-street parking is per <br /> mitted only from an alley or side street when <br /> present. Vehicular access to the off-street park <br /> ing may be taken from primary street only <br /> when an alley or side street is not present. <br />The ground floor fronting a street or other <br />right-of-way (not including alleys) shall comply <br />with the standards for the applicable frontage <br />type, Sections 41-2033 thorugh 41-2039 and <br />the Table UC-3 entitled Permitted Frontage <br />Types. <br />Table UC-3. Permitted Frontage Types <br />Use-Type Parking Guest Pkg.In-Lieu [a] <br />Residential [a] <br />[b] <br />2 / unit min 0.15 / unit guest <br />only <br />Live-Work 2 / unit min 0.15 / unit - <br />Non-Residential 1 / 300 sq ft -yes <br /> [a] May be satisfied through In-Lieu Fee and/or Park- <br />Once Program for Urban Center District, if estab- <br />lished. <br /> [a][b] Permanent Special Need Housing including <br /> senior housing, will be parked at 1 space per unit <br /> minimum. <br />[a] Except as modified to meet fire and trash service <br />requirements.