Laserfiche WebLink
shall not be located within three feet of an atmospheric column that extends <br />vertically from the perimeter of the device. At other R occupancies, the <br />minimum distance shall be ten feet. Where a permanent Building Department <br />approved hood and vent is installed, combustible construction may encroach <br />upon this column between the bottom of the hood and the vent opening. Where <br />chimneys or vents are installed, they shall have a spark arrester as defined in <br />Section 202. <br />Section 307.6.2 Devices using wood or fuels other than natural gas or <br />liquefied -petroleum gas is hereby amended as follows: <br />307.6.2 Devices usina wood or fuels other than natural aas or liauefied- <br />. • nnra„11. _ <br />ME <br />Permanent outdoor fireplaces burning wood or other solid fuel shall be <br />constructed in accordance with the California Building Code with clearance from <br />combustible construction and building openings as required therein. Fires in a <br />fireplace shall be contained within a firebox with an attached chimney. The <br />opening in the face of the firebox shall have an installed and maintained method <br />of arresting sparks. <br />The burning of wood or other solid fuel in a device is not allowed within 25 feet <br />of combustible structures, unless within an approved permanent fireplace. <br />Conditions which could cause a fire to spread within 25 feet of a structure or to <br />vegetation shall be eliminated prior to ignition. Fires in devices burning wood or <br />solid fuel shall be in accordance with Sections 305, 307, and 308. <br />Exceptions: <br />1. Portable fireplaces and fire rings/pits equipped with a device to arrest <br />sparks shall be located at least 3' from combustible construction at R-3 <br />occupancies, <br />2. Portable fireplaces, and fire pits/rings equipped with a device to arrest <br />sparks shall be located at least 15 feet from combustible structures at <br />other R occupancies. <br />Section 307.6.2.1 Where prohibited is hereby amended as follows: <br />Ordinance No. NS-XXXX <br />Page 13 of 36 <br />