Laserfiche WebLink
together with all other provisions of this article, shall be known as the city Residential <br />code. <br />Appendices which are adopted pursuant to this section, are as follows: <br />Appendix H, Patio Covers <br />Appendix J, Existing Buildings and Structures <br />SECTION 12: Section 8-2810 of the Santa Ana Municipal Code is hereby amended such <br />that it reads as follows: <br />Sec. 8-2810. Climatic and Geographic Design Criteria (Table R301.2(1)). <br />Table R301.2(1) is revised to read: <br />TABLE R301.2(1) <br />CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA <br />GROUND <br />SNOW <br />LOAD <br />WIND DESIGN <br />SEISMIC <br />DESIGN <br />CATEGORY <br />' <br />SUBJECT TO DAMAGE <br />FROM <br />WINTER <br />DESIGN <br />TEMP- <br />ICE <br />BARRIER <br />UNDERLAY- <br />MENT <br />REQUIREDh <br />FLOOD <br />HAZARDS <br />a <br />AIR <br />FREEZING <br />INDEXi <br />MEAN <br />ANNUAL <br />TEMPI <br />Speed <br />d <br />mph) <br />Topo- <br />graphic <br />effects" <br />Special <br />indborn <br />Weathering <br />L12-24"He2v <br />wind <br />debris <br />zone- <br />re ion' <br />Zero <br />110 <br />No <br />No <br />No <br />Ds or E <br />Ne II ible <br />Al <br />No <br />See <br />Exhibit B <br />0 <br />60 <br />For SI: 1 pound per square foot = 0.0479 kPa, 1 mile per hour = 0.447 m/s. <br />a. Weathering may require a higher strength concrete or grade of <br />masonry than necessary to satisfy the structural requirements of this code. <br />The weathering column shall be filled in with the weathering index (i.e., <br />"negligible," "moderate" or "severe") for concrete as determined from the <br />Weathering Probability Map [Figure R301.2(3)]. The grade of masonry <br />units shall be determined from ASTM C 34, C 55, C 62, C 73, C 90, C <br />129, C 145, C 216 or C 652. <br />b. The frost line depth may require deeper footings than indicated in <br />Figure R403.1(1). The jurisdiction shall fill in the frost line depth column <br />with the minimum depth of footing below finish grade. <br />C. The jurisdiction shall fill in this part of the table to indicate the need <br />for protection depending on whether there has been a history of local <br />subterranean termite damage. <br />Cl. The jurisdiction shall fill in this part of the table with the wind speed <br />from the basic wind speed map [Figure R301.2(A)].Wind exposure <br />category shall be determined on a site -specific basis in accordance with <br />Section R301.2.1.4. <br />Ordinance No. NS-XXXX <br />Page 7 of 36 <br />