Laserfiche WebLink
2. Turbocharged engines are not subject to this section if all exhausted gases <br />pass through the rotating turbine wheel, there is no exhaust bypass to the <br />atmosphere, and the turbocharger is in good mechanical condition. <br />(k) Section 323 1 324.1 Use of Equipment and Devices Generating Heat, Sparks <br />or Open Flames is hereby amended as follows: <br />3231. 324.1 Equipment and devices generating heat, sparks or open flames. <br />During any time of the year within Wildfire Risk Areas, within or immediately <br />adjacent to any forest- or brush -covered land or non -irrigated grass -covered land, <br />no person shall use or operate any welding equipment, cutting torches, tar pots, <br />grinding devices, or other tools or equipment that may produce a spark, fire, or <br />flame that could result in a wildfire without doing the following: <br />1. First clearing away all flammable material, including snags, from the area around <br />such operation for a distance of 30 feet or other approved method to reduce fire <br />spread into the wildlands. If 30 foot clearing cannot be achieved then an <br />alternate method shall be approved by the AHJ prior to work starting. <br />2. Maintain one serviceable round point shovel with an overall length of not less <br />than forty-six (46) inches and one backpack pump water -type fire extinguisher <br />fully equipped and ready for use at the immediate area during the operation. <br />3. Stop work when winds are 8 MPH during periods when relative humidity is less <br />than 25%, or a red flag condition has been declared or public announcement is <br />made, when an official sign was caused to be posted by the fire code official, or <br />when such fires present a hazard as determined by the fire code official. <br />4. Keep a cell phone nearby and call 911 immediately in case of a fire. <br />(1) Section 3232 324.2 Spark Arresters is hereby added as follows: <br />3232 324.2 Spark arresters. Spark arresters shall comply with Section 202, and when <br />affixed to the exhaust system of engines or vehicles subject to Section 32-3 324 shall not <br />be placed or mounted in such a manner as to allow flames or heat from the exhaust <br />system to ignite any flammable material. <br />SECTION 19: Section 14-23 is hereby amended as follows: <br />Sec. 14-23. - Emergency planning and preparedness (Chapter 4). <br />Chapter 4: Emergency Planning and Preparedness. Only the following Sections <br />listed below are adopted: <br />Ordinance No. NS-XXXX <br />Page 16 of 36 <br />75A-18 <br />