Laserfiche WebLink
property. These numbers shall contrast with their background. Where required <br />by the fire code official, address numbers shall be provided in additional <br />approved locations to facilitate emergency response. Address numbers shall be <br />Arabic numbers or alphabetical letters. Numbers shall be a minimum of 4 <br />inches (101.6 mm) high with a minimum stroke width of 0.5 inch (12.7 mm) for <br />R-3 occupancies, for all other occupancies the numbers shall be a minimum of <br />6 inches high with a minimum stroke width of 1 inch. Where access is by means <br />of a private road and the building cannot be viewed from the public way, a <br />monument, pole or other sign or means shall be used to identify the structure. <br />Address numbers shall be maintained. <br />(c) Section 510.1 Emergency responder radio coverage in new buildings is revised <br />to read as follows: <br />510.1 Emergency responder radio coverage in new buildings. All new buildings <br />shall have approved radio coverage for emergency responders within the building <br />based upon the existing coverage levels of the public safety communication <br />systems utilized by the jurisdiction measured at the exterior of the building. This <br />section shall not require improvement of the existing public safety communication <br />systems. The Emergency Responder Radio Coverage System shall comply with <br />the Orange County Sheriff's Department, Communications and Technology Division <br />guidelines and specifications and, where the functionality or performance <br />requirements in the California Fire Code are more stringent, this code. <br />Exceptions: <br />1.In buildings or structures where it is determined by the fire code official that <br />the radio coverage system is not needed, including but not limited to the <br />following: <br />a. Existing buildings or structures, unless required by the Building <br />Official and OCFA for buildings and structures undergoing <br />extensive remodel and/or expansion. <br />b. Elevators. <br />c. Structures that meet all of the following: <br />i. Three stories or less, and <br />ii. Do not have subterranean storage or parking, and <br />iii. Do not exceed 50,000 square feet on any single story. <br />d. Structures that meet all of the following: <br />i. Residential structures four stories or less, and <br />ii. Constructed of wood, and <br />iii. Do not have subterranean storage or parking, and <br />iv. Are not built integral to an above ground multi -story parking <br />structure. <br />Should a structure that is three stories or less and 50,000 square feet or smaller <br />on any single story include subterranean storage or parking, then this ordinance <br />shall apply only to the subterranean areas. <br />Ordinance No. NS-XXXX <br />11B-15 Page 15 of 29 <br />