My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
NS-2981
Clerk
>
Ordinances
>
2011 - 2020 (NS-2813 - NS-3000)
>
2020 (NS-2979 - NS-3000)
>
NS-2981
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2020 10:29:10 AM
Creation date
1/9/2020 3:43:11 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Ordinance
Doc #
NS-2981
Date
12/17/2019
Destruction Year
P
Document Relationships
2019-116 - Setting Forth Findings With Respect to Local Conditions
(Amended By)
Path:
\Resolutions\CITY COUNCIL\2011 -\2019
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(1) Section 6.7.3 is hereby amended as follows <br />6.7.3 Fire department connections (FDC) shall be of an approved type. The <br />location shall be approved and be no more than 150 feet from a public <br />hydrant. The FDC may be located within 150 feet of a private fire hydrant <br />when approved by the fire code official. The size of piping and the number <br />of 2Y2" inlets shall be approved by the fire code official. If acceptable to the <br />water authority, it may be installed on the backflow assembly. Fire <br />department inlet connections shall be painted OSHA safety red or as <br />approved. When the fire sprinkler density design requires more than 500 <br />gpm (including inside hose stream demand), or a standpipe system is <br />included, four 2'Y2' inlets shall be provided. <br />(2) Section 8.3.3.1 is hereby amended as follows: <br />8.3.3.1. When fire sprinkler systems are installed in shell buildings of <br />undetermined use (Spec Buildings) other than warehouses (S <br />occupancies), fire sprinklers of the quick -response type shall be used. Use <br />is considered undetermined if a specific tenant/occupant is not identified at <br />the time the fire sprinkler plan is submitted. Sprinklers in light hazard <br />occupancies shall be one of the following: <br />Quick -response type as defined in 3.6.4.8 <br />2. Residential sprinklers in accordance with the requirements of <br />8.4.5 <br />3. Quick response CMSA sprinklers <br />4. ESFR sprinklers <br />5. Standard -response sprinklers used for modifications or <br />additions to existing light hazard systems equipped with standard - <br />response sprinklers <br />6. Standard -response sprinklers used where individual standard - <br />response sprinklers are replaced in existing light hazard systems <br />(3) Section 8.15.1.2.7 is hereby added and revised as follows: <br />8.15.1.2.7 Concealed spaces filled with noncombustible insulation shall not <br />require sprinkler protection when approved by the fire code official. <br />(4) Section 11.1.1.1 is hereby added as follows: <br />Ordinance No. NS-2981 <br />Page 27 of 33 <br />
The URL can be used to link to this page
Your browser does not support the video tag.