My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
NS-2981
Clerk
>
Ordinances
>
2011 - 2020 (NS-2813 - NS-3000)
>
2020 (NS-2979 - NS-3000)
>
NS-2981
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2020 10:29:10 AM
Creation date
1/9/2020 3:43:11 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Ordinance
Doc #
NS-2981
Date
12/17/2019
Destruction Year
P
Document Relationships
2019-116 - Setting Forth Findings With Respect to Local Conditions
(Amended By)
Path:
\Resolutions\CITY COUNCIL\2011 -\2019
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
installed closer than 40 ft (12 m) but at least as far from the building <br />as the height of the wall facing the backflow preventer. <br />(5) Control valves installed in a fire -rated room accessible from the <br />exterior. <br />(6) Control valves in a fire -rated stair enclosure accessible from the <br />exterior. <br />Section 10.1.5 is hereby added as follows: <br />10.1.5 All ferrous pipe and joints shall be polyethylene encased per AWWA <br />C150, Method A, B, or C. All fittings shall be protected with a loose 8-mil polyethylene <br />tube or sheet. The ends of the tube or sheet shall extend past the joint by a minimum of <br />12 inches and be sealed with 2 inch wide tape approved for underground use. <br />Galvanizing does not meet the requirements of this section. <br />Exception: 304 or 316 Stainless Steel pipe and fittings <br />Section 10.4.1.1 is hereby revised as follows: <br />10.4.1.1 All bolted joint accessories shall be cleaned and thoroughly coated with <br />asphalt or other corrosion -retarding material after installation. <br />Exception: Bolted joint accessories made from 304 or 316 stainless steel. <br />Section 10.4.1.1.1 is hereby added as follows: <br />10.4.1.1.1 All bolts used in pipe -joint assembly shall be 316 stainless steel. <br />Section 10.4.3.2 is hereby deleted and replaced as follows: <br />10.4.3.2 Where approved, private fire service mains supplying systems within the <br />building shall be permitted. to extend more than 10 ft. under the building when all of the <br />requirements of 10.4.3.2.1 through 10.4.3.2.4 are met. Where fire service mains enter <br />the building adjacent to the foundation, the pipe may run under a building to a maximum <br />of 24 inches, as measured from the interior face of the exterior wall to the center of the <br />vertical pipe. The pipe under the building or building foundation shall be 304 or 316 <br />stainless steel and shall not contain mechanical joints or it shall comply with 10.4.3.2.1 <br />through 10.4.3.2.4. <br />SECTION 30: Section 14-47 is hereby amended to read as follows: <br />Sec.14-47. Appendices. <br />Ordinance No. NS-2981 <br />Page 30 of 33 <br />
The URL can be used to link to this page
Your browser does not support the video tag.