TABLE 1: REFERENCE NOISE LEVEL MEASUREMENTS <br />Noise Source Duration <br />(hh:mm:ss) <br />Ref. <br />Distance <br />(Feet) <br />Noise <br />Source <br /> Height <br />(Feet) <br />Hourly <br />Activity <br />(Mins)7 <br />Reference Noise <br />Level (dBA L50) <br />@ Ref. <br />Dist. <br />@ 50 <br />Feet <br />Roof-Top Air Conditioning Unit1 96:00:00 5' 5' 39 74.4 54.4 <br />Trash Enclosure Activity2 00:00:32 5' 5' 60 69.0 49.0 <br />Pad-Mounted Transformer3 -3 6' 5' 60 56.0 37.6 <br />Parking Lot Vehicle Movements4 01:00:00 10' 5' 60 44.0 33.5 <br />Courtyard Activity5 00:08:00 10' 4' 60 73.8 59.8 <br />Outdoor Pool/Spa Activity6 00:10:00 5' 4' 60 68.7 48.7 <br />Roof-Top Parking4 00:10:00 5' 4' 60 68.7 48.7 <br />1 As measured by Urban Crossroads, Inc. on 7/27/2015 at the Santee Walmart located at 170 Town Center Parkway. <br />2 As measured by Urban Crossroads, Inc. on 5/3/2018 at a commercial and office park trash enclosure in the City of Costa Mesa. <br />3 Source: NEMA TR 1-2013 Transformers, Step Voltage Regulators and Reactors, Table 2 sound level for a 500 kVA transformer. <br />4 As measured by Urban Crossroads, Inc. on 8/24/2016 in the parking lot of the Windemere Apartment community in the City of Riverside. <br />5 As measured by Urban Crossroads, Inc. on Saturday night, September 21, 2019 in the City of Newport Beach. <br />6 As measured by Urban Crossroads, Inc. on 7/5/2017 at the Covenant Hill Clubhouse pool in Ladera Ranch. <br />7 Anticipated duration (minutes within the hour) of noise activity during typical hourly conditions expected at the Project site based on the <br /> reference noise level measurement activity. <br />The basic noise attenuation equation shown below is used to calculate the distance attenuation based <br />on a reference noise level (SPL1): <br />SPL2 = SPL1 - 20log(D2/D1) <br />Where SPL2 is the resulting noise level after attenuation, SPL1 is the source noise level, D2 is the distance <br />to the reference sound pressure level (SPL1), and D1 is the distance to the receiver location. Table 2 <br />indicates that the hourly noise levels associated with the roof-top air conditioning units, trash enclosure <br />activity, pad-mounted transformers, parking lot vehicle movements, outdoor courtyard activity, outdoor <br />pool/spa activity and roof-top parking activities are expected to range from 31.4 to 46.9 dBA Lā‚…ā‚€ at the <br />sensitive off-site receiver locations. The operational noise level calculation worksheets are included in <br />Appendix A and include barrier attenuation provided by intervening structures between each noise <br />source and the receiver locations, where applicable, from the existing noise barriers and planned Project <br />buildings. <br />2-191