Laserfiche WebLink
Pedro A. Garcia <br />DP No. 2018-06R <br />Master ID No. 2018-141605 <br />September 27, 2019 <br /> <br /> <br />Page 10 of 15 <br /> <br />Reference the most current Orange County DAMP and the City of Santa <br />Ana LIP. <br /> <br />e. All new developments and significant redevelopments require preparation of <br />a NPDES post-construction storm water management plan in accordance <br />with the most current Orange County DAMP and the City of Santa Ana LIP <br />that includes all applicable BMPs for this “Priority Project.” <br /> <br />f. Add a note to the site plan to read “The BMPs, shown on the approved site <br />plan are only preliminary and will be revised or modified as necessary upon <br />completion of the WQMP. Prior to the issuance of the grading permit, the <br />approved grading/utility plan shall incorporate all required Structural BMPs. <br />For assistance and an informational handout (including a WQMP template),” <br /> <br />23) Revise the site plan to add the note “This site will be designed and constructed in <br />accordance with the California Regional Water Quality Control Board Santa Ana <br />Region Order No. R8-2009-0030 discharge requirements (MS4 Permit).” <br /> <br />24) Revise the site plan to allow for the safe and efficient access of trash vehicles to <br />trash receptacles. The following are the guidelines and the minimum requirements: <br /> <br />a. Depict and note the exact location(s) of the trash and recycling receptacles. <br />b. The project shall comply with all requirements specified in SAMC Sec. 16- <br />37. <br />c. Minimum 40’ x 16’ wide staging area shall be available on service days <br />from 6 a.m. to 6 p.m. <br />d. Minimum vertical clearance of 25’ at the staging area for bin service <br />clearance <br />e. Minimum 13’ vertical clearance for scout truck. <br />f. All staging areas are to be onsite. No street staging is permitted. <br />g. All driveway and staging areas must be able to sustain a minimum gross <br />weight of 60,000 lbs. per vehicle. <br />h. Maximum size of bin shall be 4 cubic yards. <br />i. Depict the trash trucks’ turning radius at all proposed internal corners. <br />j. Provide complete circulation for trash trucks, backing up into the streets is <br />not allowed for safety reasons. <br />k. All items must be noted on the final site plan. <br /> <br />Provide a copy of the will serve letter obtained from Waste Management, Inc. <br />Contact Walter Roberts at (714) 371-6747 or wrobert1@wm.com <br />25) Revise the site plan to depict trash truck access and turning template. <br /> <br />26) Revise the site plan to depict and note the installation of any new, relocation, or <br />upgrading of any existing fire protection facilities as required by the Orange County <br />Fire Authority (OCFA). Provide fire flow calculations for fire line and backflow