Laserfiche WebLink
YEARS EXPERIENCE <br />3 years <br />LICENSES / <br />CERTIFICATIONS <br />Professional Civil <br />Engineer, California. <br />No.C90365 <br />EDUCATION <br />M.S., Civil and <br />Environmental <br />Engineering, <br />California Polytechnic <br />State University, <br />San Luis Obispo, CA <br />B.S., Environmental <br />Engineering, <br />California Polytechnic <br />State University, <br />San Luis Obispo, CA <br />SOFTWARE SKILLS <br />• AutoCAD Civil 3D <br />• MicroStation <br />• ArcGIS <br />• FLOW-3D <br />• FLO-2D <br />• HEC-HMS <br />• HEC-RAS <br />• MATLAB <br />(Barrett D. Murawsly, PE <br />Civil <br />Professional Summary <br />Mr. Murawsky is a civil engineer specializing in water and wastewater treatment for both <br />centralized and decentralized systems. Over his past two years at BRADY he has assisted with <br />numerous reservoir inspections and the design and drafting of several extensive projects. His <br />attention to detail and proficient use of AutoCAD Civil 3D aid in creating profiles, site grading <br />plans, and detailed design drawings. <br />Project Experience <br />Project Engineer/Designer - HB 5 MG Reservoir Rehabilitation, Vista Irrigation District, CA <br />Designed new inlet/outlet yard pipingforthe HB reservoirto improve reservoir mixing and water <br />quality. Designed civil site work surrounding reservoirto include grading plan, paving plan, and <br />general site layout. Sized site drainage features for design rain event. Compiled contract <br />documents, including basis of design report, plans, and specifications. <br />Project Engineer/Designer - Pressure Reducing Stations, Upland, CA <br />Analyzed the distribution system hydraulics for the City of Upland, CA to determine how to <br />effectively implement pressure reducing stations to increase operation flexibility during future <br />system rehabilitation and emergency situations. Implemented pressure data loggers to track and <br />analyze system pressures at proposed pressure reducing station locations and areas of concern, <br />indicated from the hydraulic model. This data was used to establish set points for the pressure <br />reducing valves. <br />Researched existing utilities and created site plans for each proposed location. Pipeline profiles <br />were created to indicate connections to existing pipelines and establish vertical spacing <br />requirements for existing utility crossings. <br />Project Engineer/Designer - 8 MG Steel Reservoirs No. 1 and No.2 Inspection, Westminster, CA <br />Inspected two existing above ground steel reservoirs for interior and exterior coating failure. <br />Coating failure, primarily on the interior of the reservoir, resulted in corrosion of roofing members. <br />Coating defects were mapped and quantified to determine the most efficient and economical <br />solution to increase the reservoirs service life. A report was submitted to the client, which <br />emphasized the results of the inspection and recommendations for repair. <br />Project Engineer/Designer - HB 5 MG Reservoir Inspection, Vista Irrigation District, CA <br />Inspected existing above ground prestressed concrete reservoir with concrete dome roof for <br />structural deficiencies. The inspection focused on identifying cracks and spalling of the reservoir <br />footing, wall, and roof. These structural deficiencies were mapped and repair suggestions were <br />submitted to the client along with report on inspection findings. <br />Project Engineer/Designer - Pechstein 20 MG Reservoir Roof Inspection, Vista Irrigation District, <br />CA <br />Inspected existing partially buried prestressed concrete reservoir with wooden roof for structural <br />deficiencies. Inspection focused on identifying and quantifying areas of corrosion in roofing <br />hardware and locations of dry rot, delamination, and checking within the glulam beams. The <br />reservoir roof was inspected from the outside of the reservoir as well as by boat on the inside of <br />the reservoir. Structural deficiencies were mapped and a report was submitted to the client, which <br />highlighted findings and proposed that a new aluminum dome roof be installed to increase the <br />reservoirs useful life. <br />Project Engineer/Designer - Electrical Vault Inspection, HA Builder Group, CA <br />Inspected existing underground electrical vault for structural deficiencies, including concrete <br />cracks and spalling. Developed repair plans for the replacement of the existing steel vault cover <br />and conventional concrete spall repairs around vault opening. <br />Project Engineer/Designer - Retaining Wall Inspection and Design for Regulator Station, SDG&SE, <br />CA <br />Inspected existing screen wall surrounding regulator station for concrete cracks and spalling. <br />Developed repair plans for existing screen wall defects and profile for new retaining wall for site <br />expansion. <br />RICHARD BRADY &ASSOCIATES, INC. E-37 <br />25B-115 <br />