My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
TETRA TECH, INC (2)-2020-065
Clerk
>
Contracts / Agreements
>
T
>
TETRA TECH, INC (2)-2020-065
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/30/2024 12:25:38 PM
Creation date
5/6/2020 4:06:35 PM
Metadata
Fields
Template:
Contracts
Company Name
TETRA TECH, INC
Contract #
A-2020-065
Agency
PUBLIC WORKS
Council Approval Date
4/7/2020
Expiration Date
4/6/2023
Insurance Exp Date
10/1/2025
Destruction Year
2028
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L M O I M E L R M O <br />Richard F. Yeager Jr., PE Principal Corrosion En,ineer <br />Richard (Rick) F. Yeager Jr. is a California Registered Civil Engineer and a YEARS OF EXPERIENCE <br />NACE Intl Certified Cathodic Protection Specialist with a broad background in ZZ <br />corrosion engineering, inspections, and construction support services. Mr. <br />Yeager has extensive experience in water and wastewater corrosion control <br />and cathodic protection system designs, corrosivity assessments, pipe and YEARS WITH FIRIV'I <br />coating materials of construction, and inspection and monitoring of installed 15 <br />piping systems. The NACE Certification meets the definition of "Corrosion <br />Expert" as defined by the United States Environmental Protection Agency and EDUCATION <br />under 40 CPR 280A2 of the Code of Federal Regulations. Additionally, Mr. <br />Yeager has provided construction inspection services for projects that have B.S., Civil Eneineerin;l. California <br />included pipelines, water reservoirs, treatments plants, and roadways. Pulvtechnic State Llniversity. 1997 <br />National Association fl:orrosion <br />Project Experience: Engineers INA(.F. Intl) <br />As -Needed Corrosion Engineering Services &Annual Survey Basic Corrosion Course, L997 <br />Provide Cathodic Protection Survey and Performance testing of installed <br />pipelines and reservoirs. To include monitoring, testing and troubleshooting CP Design 1. L999 <br />all existing corrosion control facilities for corrosion. Performing coating <br />assessments on process facilities, water treatment plants, and buried piping . Cathodic Protection <br />systems. Then assessing system damage and evaluating cathodic protection <br />system performance and identifying repair or refurbishment requirements. A Certification Training, 2001 <br />summary report listing all observations, conclusions, and recommendations is <br />submitted at the completion of each annual survey. CERTIFICATIONS <br />• Ramona Municipal Water District <br />• Olivenhain Municipal Water District California Professional Civil En_ineer <br />• Santa Fe Irrigation District No. C70686 <br />• Leucadia Wastewater District <br />• Otay Water District NACEIntl: <br />• San Dieguito Water District <br />• City of San Diego Cathodic Protection <br />• Padre Dam Municipal Water District Specialist No. 632 1 <br />• Vallecitos Water District <br />Confined Space Entrant/Attendee <br />Corrosion Control Evaluation and CP Design <br />Certified DCBE/SBE Firm <br />Responsible for designing new and retrofit cathodic protection systems for (CA Dept, of General Services) <br />buried metallic pipelines and aboveground water storage tanks. Designs, <br />galvanic anode and impressed current, take into account soil conditions, Certified SI.,BE Firm <br />coating options, power availability and other parameters in order to achieve (.City of San Diego) <br />the most cost effective means of long term corrosion protection in accordance <br />with nationally accepted standards. SCOOP Certified Firm <br />(SDCWAI <br />• City of San Diego- Morena Pump Station & Conveyance System <br />• City of San Diego- Tierra Santa Pump Station & pipeline <br />• City of San Diego- 69th & Mohawk Pump Station <br />• City of San Diego- 30n' St Pipeline Replacement <br />1016 Broadway, Ste. A, El Cajon, CA 92021 <br />Richard F. Yeager Jr., PE Phone: 619.312.10195 <br />
The URL can be used to link to this page
Your browser does not support the video tag.