Laserfiche WebLink
Richard F. Yeager Jr., PE <br />Richard (Rick) F. Yeager Jr. is a California Registered Civil Engineer and a <br />NACE Int'I Certified Cathodic Protection Specialist with a broad background in <br />corrosion engineering, inspections, and construction support services. Mr. <br />Yeager has extensive experience in water and wastewater corrosion control <br />and cathodic protection system designs, corrosivity assessments, pipe and <br />coating materials of construction, and inspection and monitoring of installed <br />piping systems. The NACE Certification meets the definition of "Corrosion <br />Expert" as defined by the United States Environmental Protection Agency and <br />wider 40 CFR 280.L2 of the Code of Federal Regulations. Additionally, Mr. <br />Yeager has provided construction inspection services for projects that have <br />included pipelines, water reservoirs, treatments plants, and roadways. <br />Project Experience: <br />As -Needed Corrosion Engineering Services & Annual Surveys <br />Provide Cathodic Protection Survey and Performance testing of installed <br />pipelines and reservoirs. To include monitoring, testing and troubleshooting <br />all existing corrosion control facilities for corrosion. Performing coating <br />assessments on process facilities, water treatment plants, and buried piping <br />systems. Then assessing system damage and evaluating cathodic protection <br />system performance and identifying repair or refurbishment requirements. A <br />summary report listing all observations, conclusions, and recommendations is <br />submitted at the completion of each annual survey. <br />• Ramona Municipal Water District <br />• Olivenhain Municipal Water District <br />• Santa Fe Irrigation District <br />• Leucadia Wastewater District <br />• Otay Water District <br />• San Dieguito Water District <br />• City of San Diego <br />• Padre Dam Municipal Water District <br />• Vallecitos Water District <br />Corrosion Control Evaluation and CP Design <br />Responsible for designing new and retrofit cathodic protection systems for <br />buried metallic pipelines and aboveground water storage tanks. Designs, <br />galvanic anode and impressed current, take into account soil conditions, <br />coating options, power availability and other parameters in order to achieve <br />the most cost effective means of long term corrosion protection in accordance <br />with nationally accepted standards. <br />• City of San Diego- Morena Pump Station & Conveyance System <br />• City of San Diego- Tierra Santa Pump Station & pipeline <br />• City of San Diego- 6911, & Mohawk Pump Station <br />• City of San Diego- 301h St Pipeline Replacement <br />Richard F. Yeager Jr, PE <br />Principal Corrosion Fligill— -11 <br />YEARS OF EXPERIENCE <br />22 <br />YEARS WITH FIRM <br />15 <br />EDUCATION <br />H..i., Civil Eng!na�nuq, t:ahrt�rnia <br />Polvbz d�nit State Uni-. crsity. I'�°a' <br />N itlunal A;;,aaLon oP Cn rros i,,n <br />F.n,inaerc I A ACF Intl <br />• L I [c LJ['RKlun C.)UI'v I I,F <br />CP 1)esig11 1 IU`)`) <br />Cath„dic I'r•, ta,_tiun <br />CCrnficaLi, III Traill ing,20N <br />CERTIFICATIONS <br />California Professional Civil Engineer <br />No.C70686 <br />NACE Intl: <br />• Cathodic Prote�n•..n <br />Specialist No. 6:3Z L <br />Confined Space Entrant_i attendee <br />Certified DVhEjSBE Firm <br />IC.A Dept of general ;iarvices) <br />Certified �LBl' Firm <br />I City of San Drc,ol <br />SCOOP Cerrini I Plan <br />(SM AVA) <br />10 L6 Broadway, Ste A, El Cajon, CA 92021 <br />Phone: 619.31Z.019S <br />