Laserfiche WebLink
Collection System Collaborative Benchmarking Group <br />Best Practices for Sanitary Sewer Overflow (SSO) Prevention and <br />Response Plan <br />TABLE 'B' <br />rs&ZIWTrTv7r5Tm;S'• • . • • u . • u• <br />PXINd'7AIT, I <br />Water <br />Height above <br />M/H frame <br />H in inches <br />S S O FLOW <br />Q <br />Min. Sewer <br />size in which <br />these flows <br />1/8 <br />28 <br />0.04 <br />1/4 <br />62 <br />0.09 <br />3/8 <br />111 <br />0.16 <br />1/2 <br />160 <br />0.23 <br />5/8 <br />215 <br />0.31 <br />6" <br />3/4 <br />354 <br />0.51 <br />8" <br />7/8 <br />569 <br />0.82 <br />101. <br />1 <br />799 <br />1.15 <br />12" <br />1 1/8 <br />1,035 <br />1.49 <br />1 1/4 <br />1,340 <br />1.93 <br />15" <br />13/8 <br />1,660 <br />2.39 <br />11/2 <br />1,986 <br />2.86 <br />15/8 <br />2,396 <br />3.45 <br />18" <br />13/4 <br />2,799 <br />4.03 <br />17/8 <br />3,132 <br />4.51 <br />2 <br />3,444 <br />4.96 <br />21" <br />21/8 <br />3,750 <br />5.4 <br />21/4 <br />3,986 <br />5.74 <br />23/8 <br />4,215 <br />6.07 <br />21/2 <br />4,437 <br />6.39 <br />2 5/8 <br />4,569 <br />6.58 <br />24" <br />2 3/4 <br />4,687 <br />6.75 <br />2 7/8 <br />4,799 <br />6.91 <br />3 <br />1 4,910 <br />1 7.07 <br />KUM 907A IT, I � <br />Water <br />Height above <br />M/H frame <br />H in inches <br />S SO FLOW <br />Q <br />Min. Sewer <br />size in which <br />these flows <br />1/8 <br />49 <br />0.07 <br />1/4 <br />111 <br />0.16 <br />3/8 <br />187 <br />0.27 <br />6" <br />1/2 <br />271 <br />0.39 <br />5/8 <br />361 <br />0.52 <br />8" <br />3/4 <br />458 <br />0.66 <br />7/8 <br />556 <br />0.8 <br />10.. <br />1 <br />660 <br />0.95 <br />12" <br />1 1/8 <br />1,035 <br />1.49 <br />11/4 <br />1,486 <br />2.14 <br />15" <br />1 3/8 <br />1,951 <br />2.81 <br />11/2 <br />2,424 <br />3.49 <br />18" <br />15/8 <br />2,903 <br />4.18 <br />13/4 <br />3,382 <br />4.87 <br />17/8 <br />3,917 <br />5.64 <br />21" <br />2 <br />4,458 <br />6.42 <br />21/8 <br />5,000 <br />7.2 <br />24" <br />21/4 <br />5,556 <br />8 <br />23/8 <br />6,118 <br />8.81 <br />21/2 <br />6,764 <br />9.74 <br />2 5/8 <br />7,403 <br />10.66 <br />2 3/4 <br />7,972 <br />11.48 <br />30" <br />2 7/8 <br />8,521 <br />12.27 <br />3 <br />9,062 <br />13.05 <br />31/8 <br />9,604 <br />13.83 <br />31/4 <br />10,139 <br />14.6 <br />33/8 <br />10,625 <br />15.3 <br />36" <br />3 1/2 <br />11,097 <br />15.98 <br />3 5/8 <br />11,569 <br />16.66 <br />3 3/4 <br />12,035 <br />17.33 <br />3 7/8 <br />12,486 <br />17.98 <br />4 <br />12,861 <br />18.52 <br />4 1 /8 <br />13,076 <br />18.83 <br />4 1 /4 <br />13,285 <br />19.13 <br />4 3/8 <br />13,486 <br />19.42 <br />Disclaimer: <br />This sanitary sewer overflow table was developed by Ed Euyen, Civil Engineer, <br />P.E. No. 33955, California, for County Sanitation District 1. This table is provided <br />as an example. Other Agencies may want to develop their own estimating <br />tables. <br />19F-95 <br />