Laserfiche WebLink
DocuSign Envelope ID: 2117C8Ao-DE59-4584-A333-CF93B10B8E45 <br />EXHIBIT E <br />A general awareness of all OC Fair & Event Center sound systems is important to understand the critical task of maintaining sound <br />levels within a specific window for all areas in order to minimize the overall impact of sound from the OC Fair on surrounding <br />neighborhoods. <br />OC Fair sound systems will have strict sound control measures in place. <br />ALL dB references are measured as FLAT response, NOT'A' weighted. This applies to all dB levels referenced herein. <br />The OC Fair has a noise injunction specifically applied to the Pacific Amphitheatre. However, this applies to all events. <br />The injunction states that at a distant house (547 Serra Way) the level must not exceed 55 dB. The house is approximately 2,000 <br />feet from the Grandstand Arena. The Injunction applies to all sound emanating from the OC Fair, DURING Fair time. <br />For all year round events taking place outside of fair time, there is a 5 dB reduction in maximum levels. In other words, the 55 dB <br />maximum is reduced to a 50 dB maximum. <br />There is a strict 10:00 P.m. curfew in effect unless an extension of curfew is approved in writing by the CEO or COO of the 32ntl <br />District Agricultural Association (District) prior to the event. <br />GENERAL SOUND LEVEL GUIDELINES, APPLIED TO ALL AREAS: <br />NOTE: outside of fair, all references to 55 db are lowered to 50 d13. <br />1) Maximum, broadband (20 Hz to 15 KHz) noise level, measured at FOH, will not exceed peaks of 92 dB under any circumstances <br />2) Behind the stage, measured at noise level will not exceed peaks of 70 d6 under any circumstances. This includes direct FOH <br />system energy, stage monitors, backline equipment and any reflected energy from the surrounding buildings. <br />3) Note that the objective is to keep SPL at or below 55 dB in ALL areas where houses are located. <br />4) Any combination of for 2 above resulting in noise levels exceeding 55 dB in surrounding neighborhoods must result in a lowering <br />of level until the level in the neighborhood is within compliance. <br />IN SUMMARY: <br />NOTE: outside of fair, all references to 55 db are lowered to 50 dB. <br />1) No more than 55 dB in any area where a home is located. <br />2) No more than 70 dB behind stages. <br />3) No more than 92 dB at FOH. <br />4) If any combination of the above results in greater than 55 dB in any area where housing is located, levels will be immediately <br />decreased until compliance is met. <br />Measurements will be taken during each event to insure that the level is at or below an average of 92 dB at FOH, 70 dB at the rear of <br />the stage. <br />Every effort will be taken by the Contractor to insure that the noise ordinance is strictly adhered to. <br />1) In all cases, apply reasonable care to: <br />a) Not interfere with surrounding vendors activities. <br />b) Maintain a level reasonably consistent with the program material and audience size to be covered. <br />c) At no time will the audio level exceed 90 dB 50 feet from the audio system. <br />d) If speakers are in close proximity to audience members, sound level 10 feet from speakers will not exceed 85 dB. <br />e) The Noise Injunction is to be respected and adhered to at all times. <br />2) Contractor is specifically responsible for insuring compliance as Indicated herein. <br />3) Contractor will respond to requests from District personnel to reduce levels as required. <br />