Laserfiche WebLink
CITY OF SANTA ANA <br />RFP NO.: 21-034 <br />ON -CALL EMERGENCY GENERATOR MAINTENANCE AND REPAIR SERVICES <br />Contractor Responsibilities: <br />I. TIER I: PREVENTATIVE MAINTENANCE (REFER TO BID ITEMS 1 THROUGH 6) <br />Upon request, Tier I Maintenance Services shall be performed by the Contractor. Tier I <br />generator maintenance services shall at a minimum include checking the following: <br />1. Fuel (Check main and day tank fuel supply levels; day tank float switch; piping, hoses <br />and connectors; operating fuel pressure; and for any obstructions to tank vents and <br />overflow piping) <br />2. Lubrication system (Check for proper oil level and oil operating pressure; lube oil <br />heater) <br />3. Cooling system (Check coolant level, water pump(s), jacket water heater, belts, hoses, <br />fan) <br />4. Exhaust system (Check drain condensate trap and for possible leakage) <br />5. Battery System (Look for possible corrosion; check specific gravity, electrolyte level and <br />battery charger — maintenance -free batteries require routine visual inspection and <br />maintenance in accordance with manufacturer's instructions) <br />6. Electrical system (Conduct a general inspection of wiring and connections; check circuit <br />breakers/fuses) <br />7. Prime Mover/Generator (Check for debris, foreign objects, loose or broken fittings; <br />check guards and components; look for any unusual condition of vibration, leakage, <br />noise, temperature or deterioration) <br />8. Thirty (30) Minute Load Test (Contractor shall carry out 30-minute generator load tests <br />and run the generator at 30% for a minimum of 30 minutes. If a generator does not "pass" <br />the load test consistently then Contractor will ask the City of Santa Ana if a resistive load <br />bank test should be performed.) <br />Within five (5) business days of completing a load test on a generator and maintenance <br />inspection services, Contractor shall provide a completed Tier 1: Generator 30•Minute Load <br />Test Form found in APPENDIX A (or City approved alternative) to the City of Santa Ana. The <br />Contractor shall state all findings, if any, along with a proposed scope of work and complete <br />cost estimates for any recommended equipment repairs and/or replacement. Alternative <br />reporting forms may be used if approved by the City of Santa Ana. <br />II. TIER 2: PREVENTATIVE MAINTENANCE (REFER TO BID ITEMS 7 THROUGH 12) <br />Upon request, Tier II Maintenance Services shall be performed by the Contractor. In addition <br />to the items listed in APPENDIX B (the TIER II: GENERATOR INSPECTION AND <br />PREVENTATIVE MAINTENANCE CHECKLIST), the Tier II maintenance service visit shall <br />include a full change of engine oil and filter (along with a battery and coolant replacement if <br />