NOx CO PM10 PM2.5 <br />Site Preparation 16.62 13.96 0.88 0.79 <br />Grading 16.98 9.22 3.50 2.02 <br />Building Construction 12.50 12.73 0.59 0.57 <br />Paving 6.24 8.80 0.31 0.28 <br />1.30 1.81 0.07 0.07 <br />SCAQMD Thresholds1 115 715 6 4 <br />Exceeds Threshold?No No No No <br />Notes: <br />(1) <br />On-Site Pollutant Emissions (pounds/day) <br />Note: The project will disturb up to a maximum of 2 acres a day during demolition and grading (see Table 7). <br />Local Construction Emissions at the Nearest Receptors <br />Table 8 <br />Activity <br />Architectural Coating <br />The nearest sensitive receptors are the existing multi-family residential uses located approximately 155 feet (~47 meters) northeast and the <br />school use located as close as approximately 450 feet (~137 meters) east of the project site; therefore, to be conservative, the 25 meter <br />threshold was used. <br />Source: Calculated from CalEEMod and SCAQMD’s Mass Rate Look-up Tables for 2 acres at a distance of 25 m, to be conservative, in SRA 17 <br />Central Orange County. <br />Cabrillo at First Mixed-Use Residential Project <br />Air Quality, Global Climate Change, HRA and Energy Impact Analysis <br />19386346/27/2022 <br />Planning Commission 2 –87