between approximately 60 feet and 110 feet. All six bridges are single -span prefabricated steel truss bridges,
<br />bearing upon cast -in -place concrete abutments. The designs of the superstructures of the prefabricated trusses
<br />were prepared and submitted by the contractor during the construction phase. Kleinfelder provided the abutment
<br />designs and specifications for contractor superstructure designs.
<br />Chinquapin Sewer Lift Station — Metal Roof Canopy Design: Kleinfelder provided the structural design of a
<br />steel frame canopy supporting a standing seam metal roof, which was placed on an existing masonry enclosure.
<br />The canopy has a sloping roof with height that varies from 6 inches to 2.5 feet above the existing masonry wall.
<br />The supports for the canopy were bolted to the masonry wall with post -installed anchors. The roof framing was
<br />designed in accordance with the 2010 California Building Code. Kleinfelder provided structural plans and
<br />calculations, and a site visit prior to start of design to observe the existing structure and take photos and
<br />measurements documentation.
<br />EIrvine Lake Pipeline North Conversion, Santiago Hills Zone C+ Reservoir I Irvine, CA
<br />Reference: Irvine Ranch Water District, Jacob Moeder, Project Manager, 949-453-5554, moeder@irwd.com
<br />-Project Duration I Contract Value: 2014-2016 1 $934K
<br />Key Staff: Eric Ng, Christina Nishimoto, Art Garcia, Jason Brown
<br />Kleinfelder provided expert project management, structural engineering, Civil Site
<br />design, and geotechnical engineering for the design of the 2.4-MG recycled water
<br />reservoir. Kleinfelder's responsibilities included oversight and site layout design,
<br />reservoir design, appurtenance design such as strainers, backwash system, valve,
<br />and vault, overflow system, stormwater drainage system, and pipelines. The
<br />reservoir is partially buried, and the overall site layout required the design of
<br />concrete block retaining walls. Mechanical elements at the reservoir site included
<br />flow metering equipment, strainers to remove shells and other debris from the untreated water entering the
<br />reservoir from Irvine Lake.
<br />As part of the geotechnical study, Kleinfelder evaluated four reservoir sitting alternatives. A detailed geotechnical
<br />investigation was required to identify historical landslides and abrupt changes in geological formations beneath
<br />the site to optimize the reservoir location.
<br />As part of the civil site design, Kleinfelder developed the site layout plans including temporary excavation and
<br />access road plans, final grading and access road designs, retaining wall layouts, and the site stormwater
<br />-conveyance system.
<br />REFERENCES
<br />Kleinfelder has several recent, relevant, public entity references where the team has performed
<br />similar work within the past five years. Below are three references with valid, current emails. We
<br />encourage the City to reach out to these agencies and learn more about Kleinfelder's successful
<br />project delivery.
<br />Public Agency Reference
<br />Javier Soto, PE, PMP, QSD Manager
<br />Project Scope of Work
<br />On -Call Construction Inspection, Geotechnical,
<br />I
<br />Orange County Public Works
<br />Construction Materials Testing and Inspection
<br />OC Construction/Special Projects County of Orange
<br />Project Description #5
<br />714-227-1470; Javier.Soto@ocpw.ocgov.com
<br />2
<br />Edson Bancloy, Assoc. Civil Engineer
<br />City of San Diego As -Needed Engineering Services, three
<br />City of San Diego
<br />as -needed 5-year contracts
<br />858-292-6458; ebandoy@sandiego.gov
<br />Project Description #1
<br />3
<br />Dan Beers, Principal Project Manager
<br />City of Ontario/Ontario Municipal Utilities Company,
<br />City of Ontario/ Ontario Municipal Utilities District
<br />various On -Calls including As -Needed Professional
<br />909-395-2806 1 C: 818-388-0212
<br />Engineering Design Services, As -Needed Geotechnical
<br />dbeers@ontarioca.gov
<br />and Materials Testing Services
<br />Project Description #4
<br />KLH1NF'HL0HR City of Santa Ana On -Call Professional Engineering Services — No. 23-030 1 Page 20
<br />B,ght P,,pl,, Right 5,1,t
<br />
|