| BUILDING & UNIT SUMMARY 
<br />BUILDING A AREA SUMMARY 
<br />FLOOR LEVEL 
<br />TOTAL AREA (SF) 
<br />FIRST LEVEL (01) 
<br />GARAGE 
<br />22,472 
<br />FIRST LEVEL (01) 
<br />LEASING 
<br />2,337 
<br />FIRST LEVEL (01) 
<br />AMENITIES 
<br />3,211 
<br />FIRST LEVEL (01) 
<br />RETAIL 
<br />12,113 
<br />FIRST LEVEL (01) 
<br />RESIDENTIAL 
<br />10,493 
<br />50,626 
<br />SECOND LEVEL (02) 
<br />GARAGE 
<br />21,335 
<br />SECOND LEVEL (02) 
<br />AMENITIES 
<br />4,088 
<br />SECOND LEVEL (02) 
<br />RESIDENTIAL 
<br />10,956 
<br />SECOND LEVEL (02) 
<br />STORAGE 
<br />1,991 
<br />38,370 
<br />THIRD LEVEL (03) 
<br />GARAGE 
<br />21,335 
<br />THIRD LEVEL (03) 
<br />AMENITIES 
<br />15,526 
<br />THIRD LEVEL (03) 
<br />RESIDENTIAL 
<br />21,325 
<br />58,186 
<br />FOURTH LEVEL (04) 
<br />GARAGE 
<br />21,335 
<br />FOURTH LEVEL (04) 
<br />RESIDENTIAL 
<br />21,325 
<br />42,660 
<br />FIFTH LEVEL (05) 
<br />GARAGE 
<br />21,335 
<br />FIFTH LEVEL (05) 
<br />RESIDENTIAL 
<br />23,644 
<br />44,979 
<br />SIXTH LEVEL (06) 
<br />RESIDENTIAL 
<br />23,644 
<br />SEVENTH LEVEL (07) 
<br />AMENITIES 
<br />750 
<br />SEVENTH LEVEL (07) 
<br />RESIDENTIAL 
<br />22,894 
<br />23,644 
<br />a 
<br />BUILDING AREA 
<br />282,109 
<br />SITE AREA 
<br />61,989 
<br />F.A.R. 
<br />4.55 
<br />RESIDENTIAL 
<br />135,031 
<br />PARKING 
<br />107,812 
<br />RETAIL 
<br />12,113 
<br />LEASING 
<br />2,337 
<br />AMENITIES 
<br />7,299 
<br />PRIVATE OPEN SPACE 
<br />UNIT TYPE 
<br />UNIT DECK FLOOR 
<br />AREA (SF) 
<br />NUMBER OF UNITS 
<br />TOTAL (SF) 
<br />1 BEDROOM 
<br />P1.1A 
<br />68 
<br />1 
<br />68 
<br />P1.113 
<br />68 
<br />4 
<br />272 
<br />P1.1C 
<br />68 
<br />1 
<br />68 
<br />P1.1D 
<br />68 
<br />4 
<br />272 
<br />P1.1E 
<br />68 
<br />2 
<br />136 
<br />P1.1G 
<br />66 
<br />1 
<br />66 
<br />P1.1H 
<br />66 
<br />1 
<br />66 
<br />P1.1K 
<br />66 
<br />4 
<br />264 
<br />P1.3A 
<br />84 
<br />1 
<br />84 
<br />2 BEDROOM 
<br />P2.113 
<br />74 
<br />2 
<br />148 
<br />P2.1C 
<br />74 
<br />2 
<br />148 
<br />P2.1D 
<br />84 
<br />1 
<br />84 
<br />P2.1E 
<br />74 
<br />2 
<br />148 
<br />P2.1F 
<br />74 
<br />2 
<br />148 
<br />P2.1G 
<br />68 
<br />1 
<br />68 
<br />P2.1H 
<br />74 
<br />2 
<br />148 
<br />P2.1J 
<br />68 
<br />4 
<br />272 
<br />P2.2B 
<br />77 
<br />3 
<br />231 
<br />P2.2C 
<br />77 
<br />1 
<br />77 
<br />P2.2D 
<br />74 
<br />3 
<br />222 
<br />P2.2E 
<br />74 
<br />2 
<br />148 
<br />P2.2F 
<br />77 
<br />1 
<br />77 
<br />P2.2G 
<br />67 
<br />1 
<br />67 
<br />P2.2H 
<br />67 
<br />1 
<br />67 
<br />P2.2J 
<br />67 
<br />2 
<br />134 
<br />P2.2K 
<br />67 
<br />1 
<br />67 
<br />P2.2L 
<br />84 
<br />1 
<br />84 
<br />P2.2M 
<br />84 
<br />3 
<br />252 
<br />P2.2N 
<br />84 
<br />1 
<br />84 
<br />P2.2P 
<br />63 
<br />4 
<br />252 
<br />P2.2Q 
<br />63 
<br />1 
<br />63 
<br />TOTAL PRIVATE OPEN SPACE PROVIDED (SF) 
<br />4,285 
<br />TOTAL PRIVATE OPEN SPACE REQUIRED (SF) 
<br />8,450 
<br />DEFICIT (TO BE MADE UP BY COMMON INTERIOR) 
<br />4,165 
<br />COMMON INTERIOR OPEN SPACE (SF) 
<br />CLUBROOM 
<br />1791 
<br />YOGA 
<br />499 
<br />FITNESS 
<br />1436 
<br />CO -WORKING 
<br />2602 
<br />TOTAL COMMON INTERIOR OPEN SPACE 
<br />6328 
<br />BUILDING B AREA SUMMARY 
<br />FLOOR LEVEL 
<br />TOTAL AREA (SF) 
<br />FIRST LEVEL (01) 
<br />GARAGE 
<br />21,550 
<br />FIRST LEVEL (01) 
<br />RESIDENTIAL 
<br />20,501 
<br />42,051 
<br />SECOND LEVEL (02) 
<br />GARAGE 
<br />21,550 
<br />SECOND LEVEL (02) 
<br />RESIDENTIAL 
<br />20,501 
<br />42,051 
<br />THIRD LEVEL (03) 
<br />GARAGE 
<br />21,550 
<br />THIRD LEVEL (03) 
<br />RESIDENTIAL 
<br />20,501 
<br />42,051 
<br />FOURTH LEVEL (04) 
<br />GARAGE 
<br />21,550 
<br />FOURTH LEVEL (04) 
<br />RESIDENTIAL 
<br />20,501 
<br />42,051 
<br />FIFTH LEVEL (05) 
<br />RESIDENTIAL 
<br />20,501 
<br />a 
<br />H 
<br />BUILDING AREA 
<br />188,705 
<br />SITE AREA 
<br />55,828 
<br />F.A.R. 
<br />3.38 
<br />RESIDENTIAL 
<br />102,505 
<br />PARKING 
<br />86,200 
<br />RETAIL 
<br />0 
<br />LEASING 
<br />0 
<br />AMENITIES 
<br />0 
<br />PUBLIC OPEN SPACE - BLDG A 
<br />AREA 
<br />LANDSCAPE (SF) 
<br />HARDSCAPE (SF) 
<br />TOTAL (SF) 
<br />SETBACK 
<br />5483 
<br />2887 
<br />8370 
<br />LEVEL RECREATION 
<br />1002 
<br />5744 
<br />6746 
<br />ROOF DECK 
<br />95 
<br />862 
<br />957 
<br />TOTAL PROVIDED (SF) 
<br />6580 
<br />9493 
<br />16073 
<br />TOTAL REQUIRED -15% OF SITE (SF) 
<br />9298 
<br />PUBLIC OPEN SPACE - BLDG B 
<br />AREA 
<br />LANDSCAPE (SF) 
<br />HARDSCAPE (SF) 
<br />TOTAL (SF) 
<br />SETBACK & COURTYARD 
<br />8320 
<br />4021 
<br />12341 
<br />TOTAL PROVIDED (SF) 
<br />8320 
<br />4021 
<br />12341 
<br />TOTAL REQUIRED -15% OF SITE (SF) 
<br />8374 
<br />CODE ANALYSIS DATA 
<br />CODE COMPLIANCE 
<br />THIS PROJECT SHALL COMPLY WITH ALL OTHER REGULATIONS AND ORDINANCES ADOPTED BY THE STATE GOVERNING AGENCIES. 
<br />APPLICABLE CODES: 
<br />2019 EDITION OF THE CALIFORNIA BUILDING CODE (CBC) 
<br />2019 EDITION OF THE CALIFORNIA MECHANICAL CODE (CMC) 
<br />2019 EDITION OF THE CALIFORNIA PLUMBING CODE (CPC) 
<br />2019 EDITION OF THE CALIFORNIA ELECTRICAL CODE (CEC) 
<br />2019 EDITION OF THE CALIFORNIA FIRE CODE 
<br />2019 EDITION OF THE CALIFORNIA ENERGY CODE 
<br />2019 EDITION OF THE CALIFORNIA GREEN BUILDING CODE 
<br />PROJECT DESCRIPTION 
<br />PROPOSED ARE 2 RESIDENTIAL APARTMENT BUILDINGS CONSISTING OF THE FOLLOWING: 
<br />BUILDING A: 
<br />• (1) TYPE I -A GARAGE & RESIDENTIAL BUILDING, 6 UNITS, 5 AT GRADE LEVELS 
<br />• (1) TYPE III -A RESIDENTIAL BUILDING, 73 UNITS, 5 LEVELS ABOVE PODIUM 
<br />• FIREWALLS ARE USED TO SEPARATE THE BUILDING ABOVE THE PODIUM INTO 3 BUILDING PORTIONS 
<br />• (1) TYPE III -A RESIDENTIAL BUILDING, 20 UNITS, 5 LEVELS AT GRADE 
<br />• BUILDINGS COMPLY WITH CBC SECTION 510.2 AND 705.3 EXCEPTION 2 
<br />• FIRE SPRINKLER SYSTEM: NFPA-13 
<br />BUILDING B: 
<br />• (1) TYPE I -A GARAGE BUILDING, 4 AT GRADE LEVELS 
<br />• (1) TYPE III -A RESIDENTIAL BUILDING, 70 UNITS, 5 LEVELS AT GRADE 
<br />• FIREWALLS ARE USED TO SEPARATE THE BUILDING AT GRADE INTO 3 BUILDING PORTIONS 
<br />• BUILDINGS COMPLY WITH CBC SECTION 705.3 EXCEPTION 2 
<br />• FIRE SPRINKLER SYSTEM: NFPA-13 
<br />FIRE -RESISTANCE RATING FOR BUILDING ELEMENTS (HOURS) - CBC TABLE 601 
<br />BUILDING ELEMENTS 
<br />TYPE OF CONSTRUCTION 
<br />IA 
<br />IIIA 
<br />PRIMARY STRUCTURAL FRAME (CBC 202 and 704) 
<br />3 
<br />1 
<br />BEARING WALLS -EXTERIOR 
<br />3 
<br />2 
<br />BEARING WALLS -INTERIOR 
<br />3 
<br />1 
<br />NONBEARING WALLS AND PARTITIONS -EXTERIOR 
<br />CBC TABLE 602 
<br />NONBEARING WALLS AND PARTITIONS -INTERIOR 
<br />0 
<br />0 
<br />FLOOR AND ASSOCIATE SECONDARY MEMBERS 
<br />2 
<br />1 
<br />ROOF AND ASSOCIATE SECONDARY MEMBERS 
<br />1 1/2 
<br />1 
<br />SEPARATED OCCUPANCIES 
<br />OCCUPANCY TYPE 
<br />R-2 
<br />S-2 
<br />B 
<br />A 
<br />M 
<br />R-2 to S-2: 1-HR 
<br />S-2 to R-2: 1-HR 
<br />B to R-2: 1-HR 
<br />A to R-2: 1-HR 
<br />M to R-2: 1-HR 
<br />SEPARATION OF OCCUPANCIES 
<br />R-2 to B: 1-HR 
<br />S-2 to B: 1-HR 
<br />B to S-2: 1-HR 
<br />A to S-2: None 
<br />M to S-2: 1-HR 
<br />(CBC TABLE 508.4) 
<br />R-2 to A: 1-HR 
<br />S-2 to A: None 
<br />B to A: 1-HR 
<br />A to B: 1-HR 
<br />M to B: None 
<br />R-2 to M: 1-HR 
<br />S-2 to M: 1-HR 
<br />B to M: None 
<br />A to M: 1-HR 
<br />M to A: 1-HR 
<br />Occupancy group 
<br />' : 1 1' 1 1 1 '� 
<br />Total area Number of occupants (50%) Number of drinking fountains Service sink* Pool Showers 
<br />(in S.F.) 
<br />1 '11 1 :'11 1 1 
<br />Number of toilets (women) Number of toilets (men) 
<br />L1 rw 
<br />Number of urinals 
<br />Number of lavatories (women) 
<br />Number of lavatories (men) 
<br />A-3 
<br />4,975 
<br />83 
<br />0.33 
<br />1 
<br />NA 
<br />2.49 
<br />0.83 
<br />0.83 
<br />0.83 
<br />0.42 
<br />Pool/Spa 
<br />1,277 
<br />86 
<br />0.34 
<br />NA 
<br />1.72 
<br />0.72 
<br />0.57 
<br />0.57 
<br />0.54 
<br />0.54 
<br />43 
<br />Total 
<br />1 
<br />1 
<br />2 
<br />4 
<br />2 
<br />2 
<br />2 
<br />1 
<br />NOTE: IN BUSINESS AND MERCANTILE OCCUPANCIES WITH 50 OR FEWER PERSONS, ONE SINGLE USE (UNISEX) TOILET FACILITY MAY BE PROVIDED 
<br />IN OCCUPANCIES WITH 10 OR FEWER PERSONS, ONE SINGLE USE (UNISEX) TOILET FACILITY MAY BE PROVIDED 
<br />* IN COMBINED OCCUPANCY FACILITIES, MIN. ONE SERVICE SINK SHALL BE PROVIDED 
<br />IN't ill 18,412 iW 1.181 A -null 101 
<br />01 NE M N 1024NOVIIIII 
<br />ITINIM, NA I 1111111 
<br />MUTIM 
<br />10 
<br />Total area 
<br />(in S.F.) 
<br />Number of occupants (50%) 
<br />(200 load factor) 
<br />Number of drinking fountains 
<br />Service sink 
<br />Number of toilets (women) 
<br />Number of toilets 
<br />(men) 
<br />Number of urinals 
<br />Number of lavatories (women) 
<br />Number of lavatories (men) 
<br />3,000 
<br />8 
<br />1 
<br />1 
<br />1 
<br />1 
<br />1 
<br />1 
<br />1 
<br />Total area 
<br />(in S.F.) 
<br />Number of occupants (50%) Number of drinking fountains 
<br />(30 load factor) 
<br />Service sink 
<br />Number of toilets (women) 
<br />Number of toilets (men) 
<br />Number of urinals 
<br />Number of lavatories (women) 
<br />Number of lavatories (men) 
<br />2,300 
<br />39 
<br />1 
<br />1 
<br />2 
<br />1 
<br />1 
<br />1 
<br />1 
<br />Architecture + Planning 
<br />17911 Von Karman Ave. 
<br />Suite 200 
<br />Irvine, CA 92614 
<br />ktgy.com 
<br />949.851.2133 
<br />KTGY Project No: 2017-0934 
<br />Project Contact: Debbie Holland 
<br />Email: dholland@ktgy.com 
<br />Principal: 
<br />Project Designer: 
<br />Project Director: 
<br />Developer 
<br />Wil Wong 
<br />D. Schoolmeester 
<br />Debbie Holland 
<br />E D OAK 
<br />IN VES"1'JV ENTS 
<br />4199 CAMPUS DRIVE 
<br />IRVINE, CA 92612 
<br />PHONE NO. (714) 342-2502 
<br />V_ 
<br />O 
<br />N 
<br />C3� 
<br />Q 
<br />U 
<br />Q 
<br />z 
<br />Q 
<br />Q 
<br />z 
<br />Q 
<br />U) 
<br />W 
<br />W 
<br />C) 
<br />F_ 
<br />`711- 
<br />T_ 
<br />L0 
<br />06 
<br />T_ 
<br />Nt 
<br />No. Date Description 
<br />It is the clients responsibility prior to or during construction to notify the architect in writing 
<br />of any perceived errors or omissions in the plans and specifications of which a contractor 
<br />thoroughly knowledgeable with the building codes and methods of construction should 
<br />reasonably be aware. Written instructions addressing such perceived errors or omissions 
<br />shall be received from the architect prior to the client or clients subcontractors proceeding 
<br />with the work. The client will be responsible for any defects in construction if these 
<br />procedures are not followed. 
<br />SED ARCyJT 
<br />��'A 
<br />No. C29795 
<br />RENEWAL DATE 
<br />AUGUST 31, 2023 
<br />OF CAS\ 
<br />License Stamp 
<br />CODE & PROJECT 
<br />SUMMARIES 
<br />z 
<br />Q 
<br />J 
<br />`n 
<br />1r n 
<br />V / 
<br />LL 
<br />CV 
<br />CV 
<br />O 
<br />CV 
<br />1 
<br />r 
<br />O 
<br />c0 
<br />0 
<br />COPYRIGHT 
<br />AO-02 
<br /> |