Laserfiche WebLink
BUILDING COMPOSITE PLAN NOTES <br />1. THE BUILDING PLAN IS PROVIDED FOR PLAN TO PLAN RELATIONSHIPS, OVERALL BUILDING DIMENSIONS, <br />ASSEMBLIES, DETAIL REFERENCES, DECK SLOPES, GUARDRAILS AND OTHER INFORMATION NOT SPECIFIC TO <br />THE ENLARGED PLANS. SEE ENLARGED PLANS FOR ADDITIONAL INFORMATION. <br />2. UNIT NUMBERS HEREIN ARE PROVIDED FOR CONSTRUCTION PURPOSES ONLY. THIS NUMBER IS NOT THE <br />LEGAL ADDRESS. <br />ALL ALL <br />3. FOR GENERAL ACCESSIBILITY INFORMATION, SEE TO <br />AD-01 AD-02.1 <br />4. ALL DIMENSIONS ARE TO THE FACE OF STUD, U.N.O. <br />5. OFFSET ALL IMMEDIATELY ADJACENT DOOR OPENINGS 4" FROM PERPENDICULAR WALL U.N.O. <br />,� <br />6. PROVIDE PENETRATION FIRESTOP SYSTEMS PER LEGEND ON <br />-- <br />AD-XX <br />7. THE FLAME -SPREAD RATING OF INTERIOR WALLS AND CEILING FINISH MATERIALS SHALL COMPLY <br />8. WITH CBC 803. <br />----- <br />9. INTERIOR TRIMS SHALL COMPLY WITH CBC 806. <br />N <br />R /0 <br />D N <br />I <br />I I \' <br />F+__-�- <br />- <br />10. PROVIDE ALL NECESSARY CEILING OR WALL ACCESS PANELS AS REQUIRED FOR AIR CONDITIONING, <br />PLUMBING, FIRE SPRINKLER AND ELECTRICAL SYSTEMS. IN FIRE -RATED ASSEMBLIES PROVIDE FIRE -RATED <br />• `' <br />\�\X �' <br />ACCESS PANELS WITH SELF CLOSING DEVICES. <br />5-" <br />13'-2 1/8" 16-8 7/8" <br />io <br />11. PROVIDE ACOUSTICAL ASSEMBLIES PER ALL <br />\- <br />I I <br />AD 20 <br />12. INTERIOR DECORATIVE MATERIAL AND TRIM SHALL COMPLY WITH CBC 806. <br />, <br />D N <br />/'' <br />I <br />' <br />13. MOUNT ELECTRIC SWITCH AND OUTLET BOXES IN DEMISING WALLS PER 1- <br />110 <br />------ <br />AD 22 <br />- <br />14. VERTICAL AND HORIZONTAL FIRE BLOCKING SHALL CONFORM TO CBC 718.2. <br />N- <br />- - - - <br />- - - - -- <br />\ <br />` <br />15. SEE STRUCTURAL DRAWINGS FOR: <br />- <br />_ <br />\\ <br />A) SIZE & LOCATION OF FRAMING AND PLYWOOD SHEATHING <br />OO <br />o <br />i <br />B) SPECIAL NAILING AND BLOCKING REQUIREMENTS <br />15. PROVIDE CROSS VENTILATION, AT A MINIMUM RATE OF 1/150, FOR ENCLOSED FRAMING IN EXTERIOR <br />BALCONIES AND ELEVATED WALKING SURFACES THAT ARE EXPOSED TO RAIN, SNOW OR DRAINAGE FROM <br />IRRIGATION. VENTILATION SHALL BE PROVIDED BY CONTINUOUS REMOVABLE SOFFIT VENTS, RUNNING <br />zo <br />I <br />I <br />I / <br />PERPENDICULAR TO FRAMING MEMBERS, AT BOTH THE FRONT AND REAR OF JOIST SPACES TO BE <br />I <br />it' _____ <br />o <br />VENTILATED. IN FIRE -RATED BALCONIES AND ELEVATED WALKING SURFACE ASSEMBLIES, SPRINKLER <br />•, <br />' <br />PROTECTION SHALL BE EXTENDED TO THOSE AREAS. <br />I <br />I I <br />I <br />16. WHERE BALCONIES AND OTHER ELEVATED WALKING SURFACES ARE EXPOSED TO WATER, SNOW OR <br />I <br />)i O <br />IRRIGATION AND THE STRUCTURAL FRAMING IS PROTECTED BY AN IMPERVIOUS MOISTURE BARRIER, ALL <br />ELEMENTS OF THE IMPERVIOUS MOISTURE BARRIER SYSTEM SHALL NOT BE CONCEALED UNTIL INSPECTED <br />)i O <br />i <br />AND APPROVED. <br />I <br />17. PARKING GARAGE TYPE -IA CONSTRUCTION. PROVIDE NON-COMBUSTIBLE FIRE -RESISTIVE CONSTRUCTION <br />I <br />I <br />i <br />THROUGHOUT. <br />j <br />I I <br />18. VEHICLE RAMPS UTILIZED FOR PARKING SHALL NOT EXCEED SLOPE OF 1:15 (6.67%) <br />I <br />L- <br />I I <br />L-------------------------- <br />19. FOR LOCATIONS WITHIN 10 FEET OF VEHICULAR TRAFFIC AND PARKING STALLS, PROVIDE PIPE 6 <br />KITCHEN / <br />PROTECTION PER <br />AD-31 <br />20. GC TO COORDINATE PLACEMENT OF STEEL EMBED PLATES AND FASTENERS AT UNDERSIDE OF SLAB FO <br />c� <br />--- <br />STORAGE <br />SUSPENSION OF PIPES, EQUIPMENT, DUCTWORK, ETC. <br />�? <br />21. THE INTERIOR OF THE PARKING AREAS SHALL BE PAINTED WHITE AND CONTAIN SUFFICIENT LIGHTING FOR <br />in <br />SECURITY AND SAFETY. <br />22. ALL AREAS ON ALL FLOORS OF PARKING GARAGES SHALL MAINTAIN A MINIMUM OF 8'-2" CLEAR HEIGHT FROM <br />I • <br />- <br />N_ <br />= <br />DRIVING SURFACE TO ANY AND ALL OBSTRUCTIONS. <br />________ <br />CD <br />\ice' <br />I <br />I I N <br />BUILDING PLAN LEGEND <br />DOOR SYMBOL <br />A7-10 A7-20 <br />XX WINDOW & STOREFRONT SYMBOL <br />;, <br />(2) FUTURE <br />O A7 30 A7 40 <br />FD FLOOR DRAIN -SEE PLMB <br />0 <br />° <br />iLLw <br />\'\' <br />ik ' \�Ni <br />GREASE SHAFTS <br />- FIRE EXTINGUISHER CABINET. TOP AT+48" MAX AFF, X <br />FEC SEMI -RECESSED IN FRAMED WALLS. VERIFY FINAL LOCATIONS WITH <br />AD XX <br />__ <br />ABOVE <br />LOCAL FIRE AUTHORITY. <br />�\ ---- <br />* IDS DOWNSPOUT <br />-- <br />------------- <br />;< <br />DIRECTION OF SLOPE - 1/4" / FT U.N.O. <br />' <br />CORRIDOR <br />WATERPROOF TRAFFIC COATING <br />-' '\------- <br />I \ <br />/ I <br />VENTILATION <br />C <br />AD XX <br />-------- - <br />i `_� <br />i <br />iv <br />X <br />-- CONCRETE TOPPING SLAB <br />P.4 <br />I <br />IL------------ <br />I ' `� <br />I . <br />I---- <br />I <br />--- <br />I \, SHAFT <br />(PROVIDE CONTROL JOINTS AT CORNERS AND MAX. 5' 0" O.C. U.N.O.) AD XX <br />,, <br />4'-10" <br />\ w <br />\\ <br />��������� 3-HR RATED FIRE WALL <br />P.5 <br />-- <br />Y / �` � <br />2 HR RATED FIRE BARRIER <br />-------- <br />_ <br />/ <br />- <br />I <br />ail\\ <br />CONCRETE WHEEL STOP AD 31 <br />I <br />,�-- `------/�, <br />\` <br />\ <br />\\ <br />I <br />\" <br />SPOT ELEVATION RELATIVE TO 0'-0" REFERENCE ELEVATION U.N.O. <br />I <br />I <br />STA <br />I <br />I <br />w <br />_� _ ------ <br />f SEE CIVIL FOR ACTUAL FINISH FLOOR ELEVATIONS <br />\ <br />I <br />' <br />FS <br />-6" TOC FS =FINISH SURFACE <br />\ <br />; ..• <br />---------- <br />7T-_ <br />Ilk <br />I /' <br />` I <br />\` <br />X I i I <br />TQC- TOP F STRUCTURAL RAL CONCRETE SLAB <br />TO CURB =TOP OF CURB <br />I I <br />---- <br />I <br />/INI <br />ACCESSIBLE PARKING SPACE <br />M <br />®�Q <br />V <br />I <br />III III III III III III III III III III III <br />III III III III III III III <br />CV <br />CONCRETE STRUCTURAL SLAB TRANSITIONS <br />v ----- <br />DEPRESSION �LEVEL TO SLOPE <br />I--L-�--L-1----J_--J <br />-s -z-s --�-r -z-r <br />- \ <br />s <br />L-1--L-1--I--1-J--L-J--L-1 <br />-L-1--I--1--I--L-J <br />- <br />M <br />-------- <br />n <br />SLOPE TO LEVEL �i;�X DEPRESSION TO SLOPE <br />1'-6" 3'-9" <br />'-0' <br />31'-6" <br />7'-10" <br />7'-7" <br />/ MAINTAIN 8'-2" MIN. CLEAR AFF ALONG THE ENTIRE PATH TO AND FROM <br />ACCESSIBLE PARKING, INCLUDING ADJACENT AISLE. MAINTAIN 7'-0" MIN CLEAR <br />AFF IN ALL OTHER LOCATIONS OF GARAGE. <br />�� <br />_][]0000LJJ 12 12 <br />�'-------- <br />000 ❑ ❑ ❑ ❑ ❑ ❑ ❑ DETECTABLE WARNINGS, MIN 36" WIDE <br />❑❑❑❑❑❑❑❑❑❑ AD-01 AD-31 <br />X <br />WATERPROOF TRAFFIC COATING AD XX <br />---------I- CONCRETE TOPPING SLAB X <br />(PROVIDE CONTROL JOINTS AT CORNERS AND MAX. 5-0" O.C. U.N.O.) AD-XX <br />N <br />I <br />FRAMED WALL - 3-5/8" METAL STUD <br />rn <br />FRAMED WALL - 6" METAL STUD <br />o <br />FRAMED WALL - 6" METAL STUD OVER 6" x 6" CONCRETE CURB <br />``) <br />40" HIGH CMU WALL W/ 3-5/8" METAL STUD ABOVE <br />0 <br />0 <br />CMU WALL -SEE STRUCTURAL <br />� <br />Cl)X <br />1'-6" 3'!PN <br />CONCRETE WALL - SEE STRUCTURAL <br />AD-XX <br />�'. <br />X <br />------------- AIRCRAFT CABLE VEHICULAR BARRIER <br />I <br />I <br />ADAX <br />I <br />16 <br />FULL HEIGHT STEEL FENCING <br />RESTAURANT <br />i AD31 <br />I <br />i I CONCRETE COLUMN X <br />R <br />I I <br />I COLUMN CAP AD XX <br />I I <br />L J <br />co <br />• <br />O� <br />M <br />KEYNOTES <br />N <br />1❑ LINE OF FLOOR ABOVE <br />N <br />i0 <br />bo <br />• �;l <br />v'0 <br />2❑ MECHANICAL SHAFT - SEE MECHANICAL DWGS <br />\ <br />\\� <br />�\ <br />3❑ RETAIL PARKING SPACE <br />4❑ GUEST PARKING SPACE <br />�5 EV READY SPACE (FUTURE) <br />6❑ EV CHARGING SPACE (INSTALLED), REFER TO DETAIL 9/AD-31 <br />❑7 CLEAN AIR VEHICLE PARKING SPACE, REFER TO DETAIL 9/AD-31 <br />❑8 42" TALL BOLLARD, SEE STRUCTURAL AND DETAIL 2/AD-31 <br />�9 ACCESSIBLE PARKING SPACE, REFER TO DETAILS 5, 6, & 9/AD-01 AND 10/AD-31 <br />\ \ <br />i <br />� <br />10 VEHICULAR HEADOOM CLEARANCE BAR, REFER TO DETAIL 1/AD-31 <br />Cl)C? <br />A. MOUNT BOTTOM OF BAR AT 8'-2" ABOVE FINISH FLOOR <br />B. MOUNT BOTTOM OF BAR AT 7'-0" ABOVE FINISH FLOOR <br />• <br />------------ --- _ <br />M <br />11 DIAGONAL STRIPING, REFER TO DETAIL 6/AD-01 <br />---------------=' <br />� <br />-1 <br />0 <br />12 EXPANSION JOINT, REFER TO SHEET AD-33 <br />STEEL STUD AND GYPSUM BOARD PARTITION WALLS BETWEEN INDIVIDUAL STORAGE SPACES. PARTITION <br />I I <br />I <br />13 WALLS SHALL BE 7'-0" HIGH, WITH CHAIN LINK FENCING EXTENDING FROM TOP OF WALL TO UNDERSIDE OF <br />�'--- <br />--------------------------------------� <br />L---------------------- <br />I <br />-----------------------------J <br />CONCRETE SLAB ABOVE. <br />14 DIRECTIONAL ARROWS PAINTED ON CONCRETE SLAB <br />8'-9 5/8" <br />3'-0 3/4" <br />7'-0" <br />'-0' <br />3'-0" <br />16'-2" <br />2'-1 3/4" 2'-2" <br />20'-2" <br />2'-4" <br />1'-6" <br />24'-5 <br />1 /2" <br />16-8 1 /2" <br />10'-11 " <br />13'-9" <br />6'-10" <br />1 2.1 <br />4.4 <br />4.8 5.2 <br />5.5 <br />RESTAURANT <br />- LEVEL 1 <br />SCALE: 1/4"=1'-0" <br />1 <br />Architecture + Planning <br />17911 Von Karman Ave. <br />Suite 200 <br />Irvine, CA 92614 <br />ktgy.com <br />949.851.2133 <br />KTGY Project No: 2017-0934 <br />Project Contact: Debbie Holland <br />Email: dholland@ktgy.com <br />Principal: Wil Wong <br />Project Designer: D. Schoolmeester <br />Project Director: Debbie Holland <br />Developer <br />ED7 OAK <br />INVESTMENTS <br />S <br />4199 CAMPUS DRIVE <br />IRVINE, CA 92612 <br />PHONE NO. (714) 342-2502 <br />f <br />TF <br />i <br />T_ <br />O <br />Q <br />U <br />Q <br />z <br />Q <br />z <br />U) <br />LLI <br />Nw <br />U) <br />w <br />T_ <br />LO <br />06 <br />LO <br />T_ <br />No. Date Description <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />F,�S�D ARcy�T <br />No. C29795 <br />RENEWAL DATE <br />AUGUST 31, 2023 <br />s�9TF F���\� <br />of CAS\ <br />License Stamp <br />RESTAURANT <br />ENLARGED PLAN - <br />LEVEL 1 <br />BUILDING <br />A <br />A5-50 <br />N <br />1 <br />COPYRIGHT U <br />