My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Item 27 - California Building Standards Code Adoption
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2022
>
12/06/2022 Regular
>
Item 27 - California Building Standards Code Adoption
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/14/2023 8:08:20 AM
Creation date
8/14/2023 8:08:09 AM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Clerk of the Council
Item #
27
Date
12/6/2022
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Ordinance No. NS-XXX <br />Page 18 of 38 <br />Should a structure that is three stories or less and 50,000 square feet or <br />smaller on any single story include subterranean storage or parking, then <br />this ordinance shall apply only to the subterranean areas. <br /> <br />2. In facilities where emergency responder radio coverage is required <br />and such systems, components or equipment required could have a <br />negative impact on the normal operations of the facility, the fire code <br />official shall have the authority to accept an automatically activated <br />emergency radio coverage system. <br /> <br />(d) Section 510.2 Emergency responder radio coverage in existing <br />buildings is deleted without replacement. <br /> <br />(e) Section 510.3 Permit required is deleted without replacement. <br /> <br />(f) Section 510.4.2.2 Technical Criteria is adopted without amendment. <br /> <br />(g) Section 510.5.1 Approval prior to installation is adopted without <br />amendment. <br /> <br />(h) Section 510.5.2 Minimum qualification of personnel is removed <br />without replacement. <br /> <br />(i) Section 510.5.3 Acceptance test procedure is adopted without <br />amendment. <br /> <br />(j) Section 510.6.1 Testing and proof of compliance is adopted <br />without amendment. <br /> <br />Section 19. Section 14-30 of the Santa Ana Municipal Code is hereby amended <br />to read as follows: <br /> <br />Sec. 14-30. - Fire protection and Life Safety Systems (Chapter 9). <br /> <br />Chapter 9 Fire protection and Life Safety Systems is adopted in its entirety <br />with the following amendments: <br /> <br />(a) Section 903.2 Where required is hereby amended as follows: <br /> <br />903.2 Where required. Approved automatic sprinkler systems in buildings <br />and structures shall be provided when one of the following conditions <br />exists: <br /> <br />1. New buildings: Notwithstanding any applicable provisions of <br />Sections 903.2.1 through 903.2.19, an automatic fire- <br />extinguishing system shall also be installed in all
The URL can be used to link to this page
Your browser does not support the video tag.