My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Item 27 - California Building Standards Code Adoption
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2022
>
12/06/2022 Regular
>
Item 27 - California Building Standards Code Adoption
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/14/2023 8:08:20 AM
Creation date
8/14/2023 8:08:09 AM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Clerk of the Council
Item #
27
Date
12/6/2022
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ordinance No. NS-XXX <br />Page 31 of 38 <br />closer than 40 ft (12 m) but at least as far from the building as the <br />height of the wall facing the backflow preventer. <br /> <br />(5) Control valves installed in a fire-rated room accessible from the exterior <br /> <br />(6) Control valves in a fire-rated stair enclosure accessible from the exterior <br /> <br />(3) Section 10.1.5 is hereby added as follows: <br /> <br />10.1.5 All ferrous pipe and joints shall be polyethylene encased per AWWA C150, <br />Method A, B, or C. All fittings shall be protected with a loose 8-mil polyethylene <br />tube or sheet. The ends of the tube or sheet shall extend past the joint by a <br />minimum of 12 inches and be sealed with 2-inch-wide tape approved for <br />underground use. Galvanizing does not meet the requirements of this section. <br /> <br /> Exception: 304 or 316 Stainless Steel pipe and fittings <br /> <br />(4) Section 10.4.1.1 is hereby revised as follows: <br /> <br />10.4.1.1 All bolted joint accessories shall be cleaned and thoroughly coated with <br />asphalt or other corrosion-retarding material after installation. <br /> <br />Exception: Bolted joint accessories made from 304 or 316 stainless steel. <br /> <br />(5) Section 10.4.1.1.1 is hereby added as follows: <br /> <br />10.4.1.1.1 All bolts used in pipe-joint assembly shall be 316 stainless steel. <br /> <br />(6) Section 10.4.3.2 is hereby added as follows: <br /> <br />10.4.3.2. Where fire service mains enter the building adjacent to the foundation, <br />the pipe may run under a building to a maximum of 24 inches, as measured from <br />the interior face of the exterior wall to the center of the vertical pipe. The pipe <br />under the building or building foundation shall be 304 or 316 stainless steel and <br />shall not contain mechanical joints or it shall comply with 10.4.3.2.1 through <br />10.4.3.2.4. <br /> <br />(a) NFPA 13, 2016 Edition, Standard for the Installation of Sprinkler <br />Systems is hereby amended as follows: <br />(1) Section 6.7.3 is hereby amended as follows: <br /> <br />6.7.3 Fire department connections (FDC) shall be of an approved type. The <br />location shall be approved and be no more than 150 feet from a public <br />hydrant. The FDC may be located within 150 feet of a private fire hydrant <br />when approved by the fire code official. The size of piping and the number <br />of 2½” inlets shall be approved by the fire code official. If acceptable to the
The URL can be used to link to this page
Your browser does not support the video tag.