Item 22 - Natural Gas Fueling Station
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2021
>
08/17/2021 Regular
>
Item 22 - Natural Gas Fueling Station
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/9/2024 11:47:29 AM
Creation date
8/17/2023 4:03:11 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Clerk of the Council
Item #
22
Date
8/17/2021
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SERVICE AGGREEMENT —All INCLUSIVE 100% WARRANTY <br />• Visually inspect tubing, piping and valves for leaks and abnormalities <br />• Check and drain inlet filters <br />• Check valve sequencing <br />• Visually inspect all pressure relief devices for signs of failure or leakage. <br />• Verify ESD control functions and safety equipment <br />• Verify on/off switch operations <br />• Verify ESD control functions <br />• Verify 4,250-psig maximum fill pressure limits <br />Dispensers — Time Fill <br />• Visually inspect tubing, piping and valves for leaks and abnormalities <br />• Check and drain inlet filters <br />• Verify ESD control functions and safety equipment <br />Methane Gas Detection Sensors <br />• Verify and test operations <br />• Test equipment to meet OEM design criteria <br />• Repair and replace defective equipment <br />Inlet Gas Dryer <br />• Monthly - Drain pre -filter, blower housing and sump <br />• Monthly - Check differential pressure across pre -filter and after -filter elements. Replace if required <br />when gauge is approaching Red zone or 3-5 PSID rrrrrrrrrj <br />• Monthly - Check dewpoint for reading below 40F. If above, then regenerate dryer <br />• Monthly -Check and maintain operating conditions: pressure, flow, temperature within the design <br />parameters of the dryer. <br />• Six Month — Recalibrate/check span of moisture analyzer. <br />• Six Month — Replace pre -filter, after filter and separator elements if needed. <br />• Annually — Regenerate dryer, check regeneration cycle to ensure working properly <br />• 1000 hours — change oil in blower r <br />2000 Hour intervals <br />• Post compression coalescing filter element repla ment. <br />• Compressor frame oil replacement (Crankcase Oil <br />• Compressor frame oil replacement (Crankcase Oil Filter) <br />• Compressor oil strainer element cleaning. <br />• Force feed lubricator box lube oil replacement. <br />• Force feed lubricator filter replacement. <br />• Compressor interstage coalescing filter element replacement. <br />• Driver motor lubrication (Grease bearings per manufactures recommendations) <br />3000 Hour Intervals <br />• Post compression coalescing filter element replacement. <br />10225 Philadelphia Court One North Lexington Avenue 1928 32nd Ave NW <br />Rancho Cucamonga, CA 91730 White Plains, New York 10601 Rochester, MN 55901 <br />