LIGHT FIXTURE SCHEDULE <br />FBAB535.037 <br />LIGHT FCRUFE <br />SYMBOL <br />TYPE <br />LIGHT FIXTURE DESCRIPTION <br />5 <br />WiG <br />_ <br />Fl%NRE MOUNTING <br />a <br />Sc <br />_ <br />$ <br />SINGLE HEAD LED FIXTURE, POLE MOUNTED AT F29'-7' ABOVE <br />SI <br />GRWNI. TYPE IV BISTRIWTION, PROVIDE TRUNNION MOUNT. <br />CONCRCTE POLE ROUND 29'-1'TALL WITH ANTI -GRAFFITI COAi1NG <br />884 <br />106 <br />POLE NOUNT, SEE POLE <br />BASE DETAIL <br />LED <br />5000 <br />- <br />- <br />93529 <br />- <br />PROVIDE ANTI -GRAFFITI COAT ON POLE BASE. <br />g <br />VISIONAIRE LIGHTING <br />MBLx-I I-B-i4-256LC-10-5K-UNV-iN <br />ANERON POLE 06B1-29 <br />3-03 REBAR, 210. <br />FOUR III R BOLTS o <br />EACH WITH iV0 NUTS <br />AND WASHERS TO <br />ANCHOR AND ALIGN <br />POLE AND PER POLE m <br />MANORACEURER'S <br />SPECS.) <br />CONDUIT, TYPICAL <br />PER PLANS <br />BASE PLATE ANB ANCHOR <br />BOLTS FURNISH VI IN POLE. <br />DRY PACK UNDER BASE <br />I' RADIUS <br />PROVIDE ANTI -GRAFFITI <br />COATING <br />. A➢E <br />-IIF 6#5 VERTICAL REBAR <br />AND p3 CIRCULAR TIES <br />@ 12'O C. <br />CONCRETE BASE <br />-I (FT-4500 PSI) <br />PROVIDE CONTINUOUS ID8 BARE COPPER) — R"ARERi, 36' MIN, <br />6RCONDING-STRAP' DE CONDUCTOR <br />IMBED DEPTH <br />IN CONCRETE, PROVIDE CONDUCTOR, <br />I 3' CLEAR <br />COMPRESSION TYPE GROUND CLAMP ON i0 TIES <br />ONE OF THE VERTICAL REBAR IN THE 30 DIAMETER <br />POLE BASE CONNECT THE GROUNDING <br />CONDUCTOR FROM THE REBAR OR ONE i2 <br />CLAMP TO THE GROUND -DUG INSIDE THE <br />LIGHTING POLE HAND HOLE COVER. <br />ALLOW A MINIMUM OF 24-INCHES OF q3 CIRCULAR TIES <br />FREE -END' ABOVE TOP OF CONCRETE WITH I L/2 TURNS <br />BASE <br />FLUSH COMPOSITE BOLT <br />19N COVER <br />COURT POLE BASE DETAIL Nr<I121 PULL BOX DETAIL <br />PANCRETE COLLAR <br />AROUND BOX FRAME <br />FLUSH WITH TIP OF BOX. <br />COMPOSITE PILLBOX, <br />CHRISTY FIBRELYTE <br />RR09 10'x IS', DEPTH <br />AS REWIRED. <br />47Lf�XbJI�XN:1'Iwl <br />GENERALNOTES <br />THESES ➢RAVINGS AND NOTES ARE INTENDED TO <br />OVER A COMPLETE INSTALLATION OF SYSTEMS THE <br />OMISSION OR EXPRESSED REFERENCE TO ANY ITEM OF LA30R <br />OR MATERIALS REQUIRED FOR THE PROPER EXECUTION OF THE <br />VOW IN ACCORDANCE WITH PRESENT PRACTICE OF THE <br />TRADE SHALL NOT RELIEVE THE CONTRACTOR FROM <br />PROVIDING SUCH ADDITIONAL LABOR AND MATERIALS, <br />THESE PLANS AND NOTES AND ALL WORK AND <br />MATERIALS SHALL BE IN FULL ACCORDANCE WITH ALL LEGAL <br />AND INDUSTRY REQUIREMENTS AND STANDARDS INCLUDING <br />VI THOUT LIMITATION THE FOLLOWING <br />o. CALIFORNIA CURE OF REGULATIONS TITLE 24, PARTS I AND <br />2 (CALIFORNIA BUILDING CODE), 2019 EDITION, <br />H. CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 3 <br />(CALIFORNIA ELECTRICAL CODE), 2019 EDITION. <br />c. CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 6 <br />(CALIFORNIA ENERGY CODE), 2019 EDITION <br />d. CALIFORNIA COEE OF REGULATIONS TITLE 24, PART 9 <br />(CALIFORNIA FIRE CODE), 2U19 EDITION, <br />P, OTHER REGULATING AGENCIES WHICH MAY HAVE <br />AID HORITY OVER ANY PORTION OF THE WORK, INCLUDING <br />THE STATE OF CALIFORNIA DIVISION OF INDUSTRIAL <br />SAFETY, AND THOSE CODES AND STANDARDS LISTED IN THESE <br />NOTES AND SPECIFICATIONS. <br />P. THC ELECTRICAL SYSTEMS FUNCTIONALITY STANDARDS <br />SET FORTH IN TITLE 7 OF THE CALIFORNIA CIVIL CODE <br />(THE 'RIGHT TO REPAIR ACT'). <br />g, THE MANUFACTURER'S REQUIREMENTS OR RECOMMENDATIONS <br />FIR ANY INCORPORATED PRODUCTS. <br />h, IN C MOST CURRENT APPROVED ISSUES OF ANY NOTED <br />SPECIFICATIONS, CODES AND STANDARDS, INCLUDING <br />SUPPLEMENTS, UNLESS NOTED OTHERWISE <br />THE PLANS REPRESENT ONLY THE FINISHED ELECTRICAL <br />SYSTEMS, ANB ARE NOT INTENDED TO INDICATE OR REQUIRE ANY <br />CONSTRUCTION MEANS, METHODS TECHNIQUES, SEQUENCES OR <br />PROCEDURES. <br />IN USING THE PLANS FOR BIDDING OR CONSTRUCTION <br />PURPOSES, THE CONTRACTOR IS REQUIRED TO REVIEW ALL <br />OF THE PROJECT'S CONSTRUCTION DOCUMENTS AS A WHOLE <br />IN ORDER TO IDENTIFY ALL REQUIREMENTS THAT DIRECTLY OR <br />NDIRECTLY AFFECT ITS PORTION OF THE ELECTRICAL WORK, <br />EVEN REQUIREMENTS LOCATED IN SECTIONS DESIGNATED <br />AS APPLICABLE TO UTTER TRADES. IN CASE OF CONFLICTS, <br />THE CONTRACTOR SHALL EITHER OBTAIN DIRECTION FROM <br />AN APPROPRIATE OWNER REPRESENTATIVE OR OTHER- <br />WISE APPLY THE MORE STRINGENT REQUIREMENT. <br />IN INTERERETATING THE PLANS, THE FOLLOWING GENERAL <br />RULES APPLY: <br />o. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER <br />SCALED DRAWINGS, <br />b, SCALED DIMENSIONS AND GRAPHICALLY SHOWN LOCATIONS <br />ARE TO BE CONSIDERED ONLY APPRnXINATIC FIELD VERIFY <br />DIMENSIONS PRIOR TO BID. <br />c. BECAUSE TRE PLANS ARE INTENDED TO SET FORTH THE <br />REQUIREMENTS FOR COW TRUCTION IN ONLY AN INDUSTRY - <br />STANDARD LEVEL OF OLNLITY AND DETAIL, AND THEREFORE <br />ARC INTENDED TO BE SUPPLEMENTED BY APPROPRIATE <br />REAUESTS FOR CLARIFICATION AND INFORHAT ION, ERRORS <br />AND OMISSIONS AND TO BRING THESE ERRORS AND <br />OMISSIONS TO THE ATTENTION OF AN APPROPRIATE OWNER <br />REPRESENTATIVE IN A TIMELY MANNER AND ASSUMES THE <br />RISK OF THE CONSEQUENCES OF FAILING TO DO SO BEFORE <br />BIDDING OR OTHERWISE PROCEEDING, <br />d, THC CONTRACTOR SHALL REVIEW AND VERIFY ALL DIMENSIONS <br />PRIOR TO STARTING CONSTRUCTION, AND NOTIFY THE <br />ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES OR <br />INCONSISTENCIES, <br />SOBOUITTALS WILL BE REVIEWED BY THE ELECTRICAL ENGINEER, <br />IF AT ALL, ONLY PURSUANT TO THE INDUSTRY -STANDARD <br />PRDTOCDL SET FORTH IN III DOCUMENT ACLU AND IN NO <br />EVENT WILL THE THE SUBMITTAL REVIEW PROCESS RELIEVE <br />OR LESSEN THE SUBMITTING CONTRACTOR'S RESPUNSIBILITY <br />FOR AN INAPPROPRIATE SUBMITTAL <br />IN NO EVENT WILL ANY SITE VISITS BY THE ELECTRICAL <br />ENGINEER CONCERN CONSTRUCTION MEANS AND METHODS OR <br />CONSTRUCTION SAFETY, AND ALL SUCH MATTERS SHALL REMAIN <br />THE SOLE RESPONSIBILITY OF THE CONTRACTOR. <br />COPIES OF THE THE PLANS PROVIDED IN ANY ELECTRONIC FORM <br />ARE SUBJECT TO THE SAME PROVISIONS AS THE OTHER <br />INSTRUMENTS OF SERVICE PREPARED BY OR ON BEHALF OF <br />ELECTRICAL ENGINEER FOR THE PROJECT, INCLUDING WITHOUT <br />LIMITATION TIE ENGINEER'S COMMON LAW, STATUTORY OR <br />OTHER RESERVED RIGHTS, INCLUDING COPYRIGHTS. A RECIPIENT <br />IS GRANTED AT MOST A TRANSFERABLE NONEXCLUSIVE LICENSE <br />TO FIE E THE PLANS SOLELY FOR PROJECT PURPOSES AND <br />NO RECIPIENT IS AUTHORIZED TO USE OR TO ALLOW THE USE OF <br />ALL OR ANY PIRT IBM OF THESE PLANS FOR ANY OTHER PURPOSE, <br />AND ANY USE FOR ANY OTHER PURPOSE <br />URE O E WOULD <br />CONSTITUTE <br />ACTIONABL PLAGIARISM. ELECTRICAL CHIC WE <br />PR VIES <br />DOCUMENTS IN AN ELECTRONIC FORM ONLY IN ITS STANDARD <br />FORMATS AN CONVENTIONS AND WITH NO GUARANTEE OF <br />COMPATIBILITY WITH ANY RECIPIENT'S SOFTWARE OR HARDWARE <br />AND ANY USE WITH OR CONVERSION TO OTHER FORMATS OR <br />CONVENTIONS, OR THE USE WITH ANY PARTICULAR SOFTWARE <br />OR HARDWARE: AT THE RECIPIENT'S SOLD RISK, <br />9. LOCATIONS OF EXISTING UTILITIES ARE NUT SHOWN AND <br />CONTRACTOR SHALL EXERCISE EXTREME CAUTION IN EXCAVATING <br />AND TRENCHING ON THIS SITE TO AVOID EXISTING DUCTS, <br />PIPING OR CONDUIT, ETC. AND TO PREVENT HAZARD TO <br />PERSONNEL AND/OR BAA461 TO EXISTING UNDERGROUND <br />UTILITIES OR STRUCTURES WHETHER OR NOT SHOWN AND <br />INSTALLED BY ANY OTHER CONTRACTS. THE ENGINEER IS NOT <br />RESPONSIBLE FOR THE LOCATION OF UNDERGROUND UTILITIES <br />OR STRUCTURES WHETHER OR NOT SHOWN OR DETAILED BY ANY <br />OTHER CONTRACTS, TIE CONTRACTOR SHALL IMMEDIATELY <br />NOTIFY THE ENGINEER SHOULD SUCH UNIDENTIFIED CONDITIONS <br />BE DISCOVERED. THESE DRAWINGS AND NOTES DO NOT INCLUDE <br />NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY, <br />10, REFER TO THE ➢RAVINGS AND SHIP DRAWINGS OF OTHER TRADES <br />FOR ADDITIONAL DETAILS WHICH AFFECT THE PROPER <br />INSTALLATION OF THIS VOW, <br />II. THE ➢RAVINGS INDICATE, IN A DIAGRAMMATIC MANNER, THE <br />DESIRED LOCATIONS AND ARRANGEMENT OF THE COMPONENTS OF <br />ELECTRICAL WORK, DETERMINE EXACT CONDUIT ROUTING, <br />CONDUIT BENDS, AUXILIARY JUNCTION BOXES, SUPPORTS <br />AND UNDEFINED CONSTRUCTION DETAILS AS A JOB CONDITION <br />TO BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE COO <br />REQUIREMENTS. PROPER JUDGEMENT MUST BE ESPRIT SEE <br />IN <br />EXECUTING THE WORK SO AS TO SECURE THE BEST POSSIBLE <br />INS ELATION IN THE AVAILABLE SPACE AND In OVERCOME <br />LOCAL DIFFICULTIES DUE TO SPACE LIMITATIONS OR <br />INTERFERENCE OF CONDITIONS ENCOUNTERED, <br />12, IN THE EVENT CHANGES IN THE INDICATED LOCATIONS OR <br />ARRANGEMENTS ARE NECESSARY, DUE TO DEVELOPED CONDITIONS <br />IN THE BUILDING CONSTRUCTION OR REARRANGEMENT OF <br />EQUIPMENT, SUCH CHANGES SHALL BE MADE WITHOUT COST <br />PROVIDING THE CHANGE IS ORDERED BEFORE THE CONDUIT RUNS, <br />ETC., AND VURK DIRECTLY CONNED TEE TO SAME IS INSTALLED <br />AND NO EXTRA MATERIALS ARE REQUIRED. <br />13. PROVIDE AL EQUIPMENT WITH ENCLOSURES LISTED IR LABELED <br />FOR USE AND LOCATION WHERE SUCH LOUT PHENT IS INSTALLED, <br />14. GROUNDING SHALL BE EXECUTED IN ACCURD4NCE WITH ALL <br />APPLICABLE CODES AND REGULATIONS, BOTH OF THE STATE OF <br />CALIFORNIA AND LOCAL AUTHORITIES HAVING JURISDICTION. <br />15. PROVIDE 6F,OUWE WIRE IN EACH CONDUIT CONTAINING CIRCUITS <br />FEEDING RECEPTACLES. THE CONDUIT SHALL NOT BE PERMITTED <br />TO SERVE AS THE ONLY ELECTRICAL GROUND RETURN PATH, <br />16. PROVIDE HANDLE TIES AT CIRCUIT BREAKERS TO <br />SIMULTANEOUSLY BI SCONNECT ALL UNGROUNDED CONDUCTORS OF <br />MULTI -WIRE BRANCH CIRCUITS WITH A SHARED NEUTRAL, <br />17. UNLESS NOTED OTHERWISE ALL 120 VOLT NINEPINS OVER 100 <br />FEET SHALL BE 110 AA MINIMUM, OVER 175 FEET SHALL BE DB <br />AVG MINIMA. ADJUST CON➢UHT SIZE ACCORDINGLY.SEE WIRE AND <br />CABLE NOTE ON SHEET E-G 01 FOR ADDITIONAL INFORMATION <br />18. NOTIFY TIE ARCHITECT IN WRITING WHEN INSTALLATION IS <br />COMPLETE ANN THAT A FINAL INSPECTION OF THIS WORK CAN <br />BE PERFORMED. IN THE <br />EVENT BE CUTS IRE DEFICIENCIES <br />ARE FOUND DURING THIS FINAL INSPECTION, THEY SHALL BE <br />CORRECTED TO THE SATISFACTION OF THE AREHITECT BEFORE <br />FINAL ACCEPTANCE CAN BE ISSUED, <br />19. PANELBOARDS ARE EXISTING UNLESS NOTED OTHERWISE, NEW <br />CIRCUIT BEAKERS SHALL BE THE SAME TYPE AND INTERRUPTING <br />RATING AS EXISTING BREAKERS IN PANEL <br />20, WHERE CIRW IT CHANGES OR ADDITIONS OCCUR IN PANELROARDS <br />UPDATE PANEL DIRECTORY CARDS WITH NEW TYPE WRITTEN CARDS <br />INDICATION DESCRIPTION OF ALL CIRCUITS, <br />2L PERFORM CUTTING AND PATCHING OF CONCRETE/HARDSCAPE AREAS <br />WHICH MAY BE REQUIRED FOR THE PROPER INSTALLATION AND/OR <br />DEMOLITION OF ELECTRICAL WORK. PATCHING SHALL BE OF THE <br />SAME MATERIAL, WORKMANSHIP AND FINISH TO ACCURATELY <br />MATCH S <br />U <br />MONDING WORK TO SATISFACTION OF THE CITY <br />REPRESENTATIVE. <br />SYMBOL LIST <br />ALL SYMBOL DESCRIPTIONS ARE SUBJECT TO MODIFICATION AS NOTED ON THE DRAWINGS. VERIFY EXACT LOCATIONS <br />ANB HEIGHTS OF OUTLETS WITH ARCHITECTURAL INTERIOR ELEVATIONS PRIOR TO ROUGH -IN. <br />E- DESIGNATION <br />ADJACENT LINE INDICATES PANEL FRONT, ADJACENT BALLOON INDICATES PANEL <br />_ DESIGNATION 'A', SEE DRAWING E-3 FIR PANEL SCHEDULE. <br />o CIRCUIT BREAKER STATIONARY (NON-DRAWOUT), SECONDARY VOLTAGE, <br />CONDUIT, INSTALLED CONCEALED IN VALE OR IN CEILING SPACE, <br />1/2'C-2412 iH+B 3/4'C-6012 <br />�3/2'C-3812 F1'C-7 q1I <br />/4C - 4 Ii{H-HFF 1' C - 8 Al2 <br />�H#FULL-3/4'' C - 5 MMI22 -HHPfH 1 1/4' C - 9 RIC <br />— — — CONDUIT, INSTALLED CONCEALED IN OR UNDER FLOW OR BELOW GRADE, 3/4' CONDUCT MINIMUM, <br />- --E- -- EXISTING RACEWAY <br />9 HONERIR TO PANEL 'B' FOR CIRCUITS 1 1, 9 WITH SEPARATE NEUTRALS. <br />+W' <br />MDUNTIN6 HEIGHT TO CENTER LINE <br />IG <br />ISOLATED GROUND AND ISOLATED NEUTRAL <br />OF DEVICE FROM FINISH FLOOR OR <br />EXTERIOR GRADE <br />J-DJX <br />JUNCTION BOX <br />O-- <br />KEY NOTE CALLOUT. REFER TO <br />kYA <br />KILOVOLT AMPERES <br />CURESP RONDING NOTE IN <br />GRAVING WHERE CALLOUT OCCURS. <br />KN <br />KILOWATT <br />AFF. <br />ABOVE FINISH FLOOR <br />UAL <br />LONG CONTINUOUS LOAD <br />A.F.C. <br />ABOVE FINISH GRADE <br />LTG. LTS <br />LIGHTING <br />ARD <br />AMERICAN WIRE GAUGE <br />YCB <br />MAIN CIRCUIT BREAKER <br />OUP, A <br />AMPERE <br />MUD <br />MAIN LUGS ONLY <br />X.D.C. <br />AMPERES INTERRUPTING <br />NEC <br />NATIONAL ELECTRICAL CODE <br />CAPACITY (SYMMETRICAL) <br />NM <br />NOT IN CONTRACT <br />CIAC.,00. <br />CIRCUIT <br />PH. or (C <br />PHASE <br />CB <br />CIRCUIT BREAKER <br />PAONDE <br />FURNISH, INSTALL AND CONNECT, <br />c <br />CONDUIT <br />REC. BECOME <br />RECEPTACLE <br />OECD <br />CURRENT LIMITING CIRCUIT BREAKER <br />ADS <br />RIGID GALVANIZED STEEL <br />C.O. <br />CONDUIT ONLY, <br />SE[ONAIBY <br />600 VOLTS AND LESS <br />CORM <br />CONNECTED <br />IYP <br />TYPICAL <br />Du <br />DIAMETER <br />UNDO. <br />UNLESS NOTED OTHERWISE <br />END <br />ELECTRICAL METALLIC TUBING <br />Y <br />VOLTS <br />IF <br />EXHAUST FAN <br />VA <br />VOLT AMPERES <br />(E) <br />EXISTING EQUIPMENT TO REMAIN <br />wP <br />WEATHERPROOF <br />f1A <br />FULL LOAD AMPS <br />w <br />WIRE <br />GM <br />GROUND FAULT CIRCUIT INTERRUPTER <br />NP <br />SINGLE POLE <br />GFP <br />GROUND FAULT PROTECTION <br />qP <br />DOUBLE POE <br />CAD <br />GROUND <br />3P <br />TRIPLE PRE <br />SHEET INDEX <br />E-0 01 GENERAL NOTES, SYMBOL LIST, FIXTURE SCHEDULE AND DETAILS <br />E-D 02 SINGLE LINE DIAGRAMS, PANEL SCHEDULES <br />E-I.OI BASKETBALL COURT <br />E-2. 01 PHOTOMETRIC PLAN <br />E-3. 01 ELECTRICAL NOTES <br />Underground Service Alert <br />� wswllNn,cNllror„IA E <br />FBA Engineering Nm�rw.BeDPIOw. j <br />IDEA CBIlunaeYwNlq. <br />* OR 'BO * „o NOTICE TO CONTRACTOR <br />P <br />��A'f,H-IF "' ������:w� rsvulol ss wicormucraa Acarr crs�iaNFls <br />ADIGAIERi iICMETAWBIBffl, GALLBit AT1f/Si TWlOTONAB <br />pREVISIONS REFERENCES ir EUPP€RW516x 04izO21 GENERAL NOTES, SYMBOL UST, FUTURE SCHEDULE AND DETAILS `- <br />: ELECTRICAL ENGINEER <br />NUMB A D E w PPAo fD N6, LLEN FNAH.AMK No xx-x -xx NN NN NAro --_ --N ---- --K DESIGNED: XX DRAM. CP CHECKED. RZ EL SALVADOR PARK BASKETBALL COURT LIGHTING j <br />RDNS <br />HE <br />CEO TRUCTADILITY O FOR PROJECT LIMITS <br />`v RU <br />u AND REMCONSTRU TIO <br />FOR CON6T DEDN: <br />% PUBLIC WORKS AGENCY <br />a aM/zozl <br />JASDN CABAIEL PRINCIPAL CIYIL ENGINEER RCE N0.: 6296 CITY OF SANTA ANAL SNEFFN OF 1 <br />