My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Item 07 - ORDINANCE AMENDING CHAPTERS 8 AND 14 OF SAMC
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2022
>
12/20/2022 Special & Regular
>
Item 07 - ORDINANCE AMENDING CHAPTERS 8 AND 14 OF SAMC
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 12:42:55 PM
Creation date
8/22/2023 12:42:47 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Clerk of the Council
Item #
7
Date
12/20/2022
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Ordinance No. NS-XXX <br />Page 6 of 30 <br />code, as thus amended, together with all other provisions of this article, <br />shall be known as the city residential code. <br /> <br />Appendices which are adopted pursuant to this section, are as follows: <br /> <br />Appendix H, Patio Covers <br /> <br />Appendix J, Existing Buildings and Structures <br /> <br />Section 10. Section 8-2810 of the Santa Ana Municipal Code is hereby amended <br />to read as follows: <br /> <br /> Sec. 8-2810. - Climatic and Geographic Design Criteria (Table R301.2). <br /> <br />Table R301.2 is revised to read: <br /> <br />TABLE R301.2 <br />CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA <br /> <br />GROUND <br />SNOW <br />LOAD <br />WIND DESIGN <br />SEISMIC <br />DESIGN <br />CATEGORY <br />f <br />SUBJECT TO DAMAGE <br />FROM <br />WINTER <br />DESIGN <br />TEMP e <br />ICE <br />BARRIER <br />UNDERLAY- <br />MENT <br />REQUIRED h <br />FLOOD <br />HAZARDS <br />g <br />AIR <br />FREEZING <br />INDEX i <br />MEAN <br />ANNUAL <br />TEMP j <br />Speed <br />d <br />(mph) <br />Topo- <br />graphic <br />effects k <br />Special <br />wind <br />regionl <br />Windborne <br />debris <br />zonem <br />Weathering <br />a <br />Frost <br />line <br />Depth <br />b <br />Termite <br />c <br />Zero 95 No No No D2 or E Negligible 12-24” <br />Very <br />Heavy 43 No <br />See <br />Exhibit B 0 60 <br /> <br />For SI: 1 pound per square foot = 0.0479 kPa, 1 mile per hour = 0.447 m/s. <br /> <br />a. Weathering may require a higher strength concrete or grade of masonry <br />than necessary to satisfy the structural requirements of this code. The <br />weathering column shall be filled in with the weathering index (i.e., "negligible," <br />"moderate" or "severe") for concrete as determined from the Weathering <br />Probability Map [Figure R301.2(3)]. The grade of masonry units shall be <br />determined from ASTM C 34, C 55, C 62, C 73, C 90, C 129, C 145, C 216 or C <br />652. <br /> <br />b. The frost line depth may require deeper footings than indicated in Figure <br />R403.1(1). The jurisdiction shall fill in the frost line depth column with the <br />minimum depth of footing below finish grade. <br /> <br />c. The jurisdiction shall fill in this part of the table to indicate the need for <br />protection depending on whether there has been a history of local subterranean <br />termite damage. <br /> <br />d. The jurisdiction shall fill in this part of the table with the wind speed from <br />the basic wind speed map [Figure R30l.2(A)].Wind exposure category shall be <br />determined on a site-specific basis in accordance with Section R301.2.1.4. <br />
The URL can be used to link to this page
Your browser does not support the video tag.