Laserfiche WebLink
DBA No. 2023-01— 4th and Grand (1212 E. Fourth Street) <br />August 28, 2023 <br />Page 7 <br />Standard <br />Analysis <br />Open Space Standards <br />Pursuant to Section 41-2022 of the TZC, the residential building is designed <br />as Flex Block Building Type. This building type requires common open space <br />to be designed as a courtyard or in the front as a forecourt, have it open to <br />the sky, and to be equal to 15-percent of the lot. Moreover, private open <br />space is required to be provided for each residential unit, no less than 50 <br />square feet with a minimum dimension of six feet in each direction. The total <br />common open space required is 1,875 square feet and the total private open <br />space required is 750 square feet. <br />As proposed, the project provides 433 square feet of common interior space, <br />provided in the form of lobby space (approximately 3.5-percent of lot) to be <br />furnished (e.g., coffee tables, chairs, lounge tables, etc.), where feasible. The <br />project also provides 591 square feet of private open space, in the form of <br />private decks for nine units. The gross site area and existing site conditions <br />severely restrict the ability for the project to accommodate any common open <br />space, and restrict the ability to provide the fully required private open space. <br />Providing the required common open space standard would lead to the <br />elimination of three or more units, which would affect the feasibility to <br />construct the project. In order to maintain the current proposed unit count, <br />the developer would be required to construct additional floor levels or <br />required to provide underground parking, which would further increase <br />development costs and make the project financially infeasible. To help <br />alleviate the common open space deficiency, the project proposes an <br />average of 40 square feet of private open space per unit, through use of <br />rivate balconies/decks. <br />Landscaping Standards <br />Pursuant to Section 41-2020 of the TZC, all setbacks, yards, and shared <br />common open spaces are required to be landscaped. In addition, a <br />landscape buffer of not less than five feet is required to be provided to <br />separate parking lot from an adjacent properties and the surface parking lot <br />is required to be landscaped per City's commercial area standards. <br />As designed, the project provides a landscape buffer of two feet proposed <br />along the western property lines, three feet less than required. In addition, <br />the project does not provide the required landscape planters in the surface <br />parking lot. Due to site constraints, smaller than average lot size, and <br />parking and landscaping requirements, the required landscape buffer and <br />landscape planters cannot be accommodated. Maintaining the required <br />landscape standards would result in a site redesign, reducing the number <br />of parking stall, the drive aisle width, the ability of trash trucks to service the <br />site, and ultimately lead to the loss of bedroom units, resulting in the project <br />becoming infeasible. In order to provide the required landscaping and <br />maintain the current proposed unit count, the developer would be required <br />to construct an additional level, resulting in a different type of construction <br />(steel -frame versus wood), or build underground parking, further increasing <br />development costs. <br />When analyzed cumulatively, the requested concessions and waivers could be avoided if <br />the project were designed on a different site or using a different site plan. If the project were <br />designed with a multi -level parking and/or subterranean parking structure, or if the applicant <br />used different building materials to construct a taller project, additional area on site would <br />become available to provide the ground floor commercial, minimum required open space, <br />