Sec. 8-317. Ail Work to be Inspected <br /> <br /> Ail plumbing and drainage <br />the Administrative Authority to <br />the requirements of this code. <br /> <br />systems shall be inspected by <br />insure compliance with all <br /> <br />Sec. 8-318. Notification <br /> <br /> It shall be the duty of the person doing the work autho- <br />rized by the permit to notify the Administrative Authority <br />orally or in writing, that said work is ready for inspecticn. <br />Such notification shall be given not less than twenty-four <br />(24) hours before the work is to be inspected. <br /> <br /> It shall be the duty of the person doing the work autho- <br />rized by the permit, to make sure that the work will stand the <br />tests prescribed elsewhere in this code, before giving the <br />above notification. <br /> <br /> SECTION 4: That the Santa Aha Municipal Code is hereby <br />amended by renumbering the division of Art'icle III of Chapter 8 <br />entitled "Division 2. Amendments" so that the said section reads <br />"Division 3. Amendments". <br /> <br /> SECTION 5: That the Santa Aha Municipal Code is hereby <br />amended by adding a section to be numbered 8-370, to Division 3 <br />of Article III of Chapter 8, which said section reads as follows: <br /> <br />Sec. 8-370. Vertical Wet Venting (Section 613) <br /> <br /> Section 613 of the Uniform Plumbing Code is amended to read <br />as follows: <br /> <br />(a) <br /> <br />Vertical wet venting is limited to sections of vertical <br />drainage piping serving not more than two fixtures <br />set on the same floor level in private living quarters <br />(residential uses only) and having a discharge rating <br />of not more than two (2) units each. <br /> <br />(b) <br /> <br />In each such installation the vertical drain shall be <br />one (1) pipe size larger than the upper fixture inlet, <br />but in no case smaller than the lower fixture inlet <br />whichever is the larger, and the developed length <br />between any two (2) such inlets shall at no time be <br />greater than five (5) times the diameter of the inter- <br />vening wet vented section. Identical fixtures installed <br />back to back shall have their fixture inlets at the same <br />level. <br /> <br />(c) <br /> <br />The unit load on the common vent serving the two (2) <br />fixtures shall be the sum of the unit values of such <br />fixtures. <br /> <br />(d) Fixtures that rough in above the floor shall not be <br /> combined with fixtures that rough in below the floor. <br /> <br /> SECTION 6: If any section, subsection, sentence, <br />clause, phrase or portion of this ordinance is for any <br />reason held to be invalid or unconstitutional by the deci- <br />sion of any court of competent ~urisdiction, such decision <br />shall not affect the validity of the remaining portions of <br />this ordinance. The City Council of the City of Santa Ana <br />hereby declares that it would have adopted this ordinance <br />and each section, subsection, sentence, clause, phrase or <br />portion thereof irrespective of the fact that any one or <br />more sections, subsections, clauses, phrases or portions be <br />declared invalid or unconstitutional. <br /> <br />-9- <br /> <br /> <br />