My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
NS-1518
Clerk
>
Ordinances
>
1953 - 1999 (NS-001-NS-2415)
>
1980 (NS-1517 - NS-1561)
>
NS-1518
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2012 1:04:21 PM
Creation date
6/26/2003 10:08:06 AM
Metadata
Fields
Template:
City Clerk
Doc Type
Ordinance
Doc #
NS-1518
Date
2/19/1980
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ORDINANCE NO. NS-15{8~ <br />Page Five <br /> <br /> EXCEPTION: Unreinforced masonry walls in buildings <br />not having a rating classification of I may be analyzed in <br />accordance with Section 8-2006. <br /> <br /> C. ANCHORAGE AND INTERCONNECTION. Anchorage and <br />interconnection of all parts, portions and elements of the <br />structure shall be analyzed and designed for lateral forces <br />in accordance with the equation F~ = IC~SW~ as modified by <br />Table C. Minimum anchorage of masonry ~al{s to each floor <br />or roof shall resist a minimum force of 200 pounds per <br />lineal foot acting normal to the wall at the level of the <br />floor or roof. <br /> <br /> TABLE C <br /> HORIZONTAL FORCE FACTORS "IS" <br />FOR PARTS OR PORTIONS OF STRUCTURES <br /> <br />RATING <br />CLASSIFICATION IS <br /> <br />I 1.50 <br />II 1.00 <br />III & IV 0.75 <br /> <br /> D. LEVEL OF REQUIRED REPAIR. Alterations and repairs <br />required to meet the provisions of this Article shall comply <br />with all other applicable requirements of this Code unless <br />specifically excluded elsewhere in this Article. <br /> <br />E. REQUIRED ANALYSIS. <br /> <br /> 1. CONTINUOUS STRESS PATH. A complete, continuous <br />stress path from every part or portion of the structure to <br />the ground shall be provided for the required horizontal <br />forces. <br /> <br /> 2. POSITIVE CONNECTIONS. Ail parts, portions or <br />elements of the structure shall be interconnected by positive <br />means. <br /> <br />F. ANALYSIS PROCEDURE. <br /> <br /> (1) GENERAL. Stresses in materials and existing <br />construction utilized to transfer seismic forces from the <br />ground to parts or portions of the structure shall conform <br />to those permitted by the Uniform Building Code and those <br />materials and types of construction specified in Section <br />8-2006. <br /> <br /> (2) CONNECTIONS. Materials and connectors used <br />for interconnection of parts and portions of the structure <br />shall conform to the Uniform Building Code. <br /> <br /> (3) UNREINFORCED MASONRY WALLS. Unreinforced <br />masonry walls shall be analyzed to insure their capability <br />of resisting superimposed vertical loads in addition to the <br />seismic forces required by this Article. <br /> <br /> Allowable stresses in such walls shall be obtained <br />by tests utilizing values established by laboratory testing <br />as specified in Section 8-2006E. However, no allowable <br />tension stress will be permitted. Walls not capable of <br />resisisting the applied loads shall be strengthened to <br />resist the forces specified in this Article or shall be <br />removed and replaced. <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.