149 <br />ORDINANCE NS-2274 <br />Page7 <br /> <br />the site of the premises to be protected. <br /> <br />In all other cases: The required hydrant or hydrants <br />shall be located on the site of the premises to be <br />protected, except that any required hydrant may be <br />located on a public street if such location is within one <br />hundred fifty (150) feet of all portions of the exterior <br />walls of the building to be protected. <br /> <br /> Where more than one fire hydrant is located on the site <br />of the premises to be protected, or where a combination of <br />hydrants located on such site and a public street are used to <br />meet the distance requirements, the required fire flow in <br />gallons per minute may be divided between such hydrants <br />provided: <br /> <br />That the combination of hydrants will deliver the <br />required flow, and <br /> <br />That no single hydrant has a flow of less than one <br />thousand five hundred (1,500) gallons per minute <br />with a residual pressure measured at the hydrant <br />outlet of not less than twenty (20) pounds per <br />square inch during times of average daily consump- <br />tion. <br /> <br /> Water supply may consist of reservoirs, pressure tanks, <br />elevated tanks, water mains, or other fixed system capable of <br />supplying the required fire flow, subject to the approval of <br />the fire marshal. The precise location, number and type of <br />fire hydrants connected to a water supply to be provided in <br />accordance with this subsection shall be subject to the <br />approval of the fire marshal. All hydrants shall be accessible <br />to the fire department apparatus by roadways meeting the <br />requirements of Section 902. <br /> <br /> No use of an existing building, or any portion thereof, <br />for either a place of assemblage or a Group H occupancy, as <br />defined in subsections 1003.2.2 and 1003.2.5, shall be <br />initiated or expanded unless the building as a whole will <br />comply with the requirements of this subsection 903.2 such as <br />would apply to the new construction of such building for the <br />same uses. <br /> <br /> For purposes of this section, an existing building or <br />structure shall be deemed to have a value equal to the current <br />cost of construction of a building or structure of the same <br />size and type of construction. In determining such value, the <br />fire marshal shall be guided by the most recent building <br />valuation data published by the International Conference of <br />Building officials. <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.