My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1917 (#619-628)
Clerk
>
Ordinances
>
1886 - 1952
>
1916-1920
>
1917 (#619-628)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2012 1:07:39 PM
Creation date
4/22/2003 11:23:30 AM
Metadata
Fields
Template:
Pre-Charter
Year
1917
Pre-Charter - Doc Type
Ordinances
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
207 <br /> <br />turee in the City of Santa Ana, within the above Fire Limits, <br />which wires are used fcr light, heat or power shall be encased <br />in approved metal conduit, armored cable or metal moulding; only <br />rigid conduit construction to be used on all new work; All service <br />switches, cut outs and tablet boards mounted in approved metal <br />box, rigid conduit or a~mored cable must be strapp~ or supported <br />at each outlet and every five feet if on the underside of timbers, <br />and in all buildings of open construction or every ten feet if <br />on top of timbers, if same are more than three feet apart, except <br />in cases where armored cable have to be fished in. Ordinary black <br />or galvanized pipe shall not be approved for use as conduit. All <br />conduit or metal moulding exceeding 10 feet in length or contmin- <br /> <br /> ing more than one outlet shall be grounded with not less than $ l0 <br /> which <br />wire shall be protected from mechanical injury. Flexible conduit <br /> <br />shall not be allowed in brick walls or concrete or where expose d <br />to moisture unless lead lined,' outlet boxes shall be required in <br />all cases ( as provided for rigid conduit; Junction boxes shall be <br />required in all cases where conduit is run in connection with knob <br />and tube work; wiremen must solder and tape all joints at all out- <br />lets bringing out such wires as are necessary to connect with <br /> <br /> fixtures. <br /> All buildings used as stores, hospital, mills, factories, <br /> <br />foundries, machine shops, canneries, <br />churches, schoolhouses, auditoriums, <br />people congregate shall be wired as <br /> <br />packing houses, garages, <br />theaters and buildings where <br />those above mentioned. <br /> <br /> All wiring installed on the outside walls in said dis- <br />trict or any store front or any outside wall of a brick or con- <br />~te building shall be in rigid conduit. <br /> <br /> All service wires in buildings not <br /> <br />No.1, shall be brought in in rigid conduit <br /> <br />All main line switches shall be placed in an approved metal box <br />not to exceed 6 feet from the floor and to be located in a ready <br />and accessible place. The cover of said box shall be so mou~ted <br />as to be closed by gravity or with a spring. <br /> <br /> All accessible inside wiring shall be knobbed at least <br />every four feet six inches. All outlets shall be loomed to the <br />last knob. All wiring shall be clear from wood, pipes and other <br />portions of the structure wherein such wiring exists. No rubbish <br />shall be permitted to come in contact with any electrical wiring. <br />The use of waterproof or iron wire, or wire of less than No.14 <br />B and $ guage is prohibited. All Joints shall be soldered and <br />taped. Backing boards shall be installed at all ceiling outlets. <br />The use of open fuses in cutouts, tablet boards or main switches <br />is prohibited. All cutout cabinets inside of doors thereto shall <br />be lined with at least 1/8 inch asbestos. No circuit shall carry <br />over l2 light outlets or over 660 Watts. Unless loomed, all wires <br />shall be separated by mt least 5 inches. If more than three air- <br />cults are in use, m three-wire feed shall be required. The use <br /> <br />included in District <br />to the main line switch. <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.