Laserfiche WebLink
21PULL SIDE18"MIN.IF PILE HEIGHTEXCEEDS 1/4", THENEDGES MUST HAVEBEVELED TRIMEXPOSED EDGE1/2" MAX. PILE THICKNESSTRANSITION TRIMFIRM PAD48" MAX. <br />48" MAX. <br />TOP OF MOUNTING BRACKET 27" MAX.SHOWERS REQUIRED TO BE ACCESSIBLE SHALL COMPLY WITH CBC SECTIONS 1127A.5.3 AND 11B-608.A.SHOWERS SHALL BE CONSISTENT WITH ONE OF THE FOLLOWING SIZES AND SHALL BE MEASURED FROM THE FACE OF WALL SURFACES:1.ROLL-IN SHOWER, 60" MIN. IN WIDTH BY 30" MIN. IN DEPTH WITH A FULL OPENING WIDTH ON THE LONG THE SIDE, SEE FIGURE 16.1 BELOW.2.ALTERNATE ROLL-IN SHOWER, 60" MIN. IN WIDTH BY 36" IN DEPTH WITH AN ENTRANCE OPENING WIDTH OF 36", SEE FIGURE 16.2 BELOW.3.ALTERNATE ROLL-IN SHOWER WITH OPTIONAL ENCLOSURE, 60" MIN. IN WIDTH BY 36" MIN. IN DEPTH AS LONG AS THE ENTRANCEOPENING WIDTH IS A MIN. 36", SEE FIGURE 16.3 BELOW.B.THRESHOLDS IN ROLL-IN TYPE SHOWERS SHALL BE 1/2" HIGH MAX. CHANGES IN LEVEL UP TO 1/4" MAY BE VERTICAL AND WITHOUT EDGETREATMENT. CHANGES IN LEVEL BETWEEN 1/4" AND 1/2" SHALL BE BEVELED WITH A SLOPE NO GREATER THAN ONE UNIT VERT. IN 2 UNITSHORIZ.C.SHOWER COMPARTMENT FLOOR SURFACES SHALL BE STABLE, FIRM AND SLIP RESISTANT. THE MAXIMUM SLOPE OF THE FLOOR SHALL BE1/4" PER FOOT IN ANY DIRECTION. WHEN DRAINS ARE PROVIDED, GRATE OPENINGS SHALL BE 1/4" MAXIMUM AND LOCATED FLUSH WITH THEFLOOR SURFACE.D.WHERE, WITHIN THE SAME FUNCTIONAL AREA, TWO OR MORE ACCESSIBLE SHOWERS ARE PROVIDED, THERE SHALL BE AT LEAST ONESHOWER CONSTRUCTED OPPOSITE HAND FROM THE OTHER OR OTHERS (THAT IS, ONE LEFT-HAND CONTROL VERSUS ONE RIGHT-HANDCONTROL).E.WATER CONTROLS SHALL BE OF A SINGLE-LEVER DESIGN, OPERABLE WITH ONE HAND, AND SHALL NOT REQUIRE TIGHT GRASPING,PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE THE CONTROLS SHALL BE NO GREATER THAN 5 LBS. THECENTERLINE OF THE CONTROLS SHALL BE LOCATED 39" TO 41" ABOVE THE SHOWER FLOOR AND LOCATED WITHIN THE SHOWER PER THEFIGURES WITHIN.F.A SHOWER SPRAY UNIT WITH A HOSE 59" INCHES LONG MINIMUM THAT CAN BE USED BOTH AS A FIXED POSITION SHOWER HEAD AND AS AHAND-HELD SHOWER SHALL BE PROVIDED. THE SHOWER SPRAY UNIT SHALL HAVE AN ON/OFF CONTROL WITH A NON-POSITIVE SHUT-OFF.IF AN ADJUSTABLE-HEIGHT SHOWER HEAD OR A VERTICAL BAR IS USED, THE BAR SHALL BE INSTALLED SO AS NOT TO OBSTRUCT THE USEOF GRAB BARS. SHOWER SPRAY UNITS SHALL DELIVER WATER THAT IS 120°F MAXIMUM. WHERE SUBJECT TO EXCESSIVE VANDALISM, TWOFIXED SHOWER HEADS SHALL BE INSTALLED INSTEAD OF A HAND-HELD SPRAY UNIT IN FACILITIES THAT ARE NOT TRANSIENT LODGINGGUEST ROOMS. EACH SHOWER HEAD SHALL BE INSTALLED SO IT CAN BE OPERATED INDEPENDENTLY OF THE OTHER AND SHALL HAVESWIVEL ANGLE ADJUSTMENTS, BOTH VERTICALLY AND HORIZONTALLY.G.A FOLDING SEAT SHALL BE SIZED AND LOCATED AS SHOWN BELOW. SEE DETAIL 13 THIS SHEET FOR SEAT STRENGTH AND MOUNTINGREQUIREMENTS.H.GRAB BARS SHALL BE LOCATED ON WALLS ADJACENT TO AND OPPOSITE THE SEAT. GRAB BARS SHALL ALSO COMPLY WITH THE DIAMETER,LOADING AND PROJECTION REQUIREMENTS OF DETAIL 13 ON THIS SHEET. GRAB BARS SHALL BE MOUNTED BETWEEN A MINIMUM 33" AND AMAXIMUM 36" ABOVE THE SHOWER FLOOR. L-SHAPED GRAB BARS ARE PERMISSIBLE OR MULTIPLE GRAB BARS INSTALLED AT THE SAMEHEIGHT AND NO MORE THAN 6" FROM ADJACENT WALLS. GRAB BARS MAY BE MOUNTED ON WALLS ADJACENT TO AND OPPOSITE THE SEAT,BUT SHALL NOT EXTEND TO INCLUDE THAT PORTION OF WALL OVER THE SEAT.I.WHEN A SOAP DISH IS PROVIDED, IT SHALL BE LOCATED ON THE CONTROL WALL AT A MAXIMUM HEIGHT OF 40" ABOVE THE SHOWER FLOOR,AND WITHIN THE 27" MAXIMUM REACH LIMITS FROM THE SEAT.J.ENCLOSURES, WHEN PROVIDED FOR SHOWER COMPARTMENTS, SHALL NOT OBSTRUCT CONTROLS OR TRANSFER FROM WHEELCHAIRSONTO SHOWER SEATS.17" MIN. <br />19" MAX.12" MAX.42" MIN.33" - 36" <br />19" MIN. <br />33" - 36"12" MIN.24" MIN.36" MIN.SIDE WALLREAR WALLCL24" MIN.7" - 9"WATER CLOSETS REQUIRED TO BE ACCESSIBLE SHALL COMPLY WITH CBC SECTION 1127A.2.1, 1127A.2.3, ICC_A117.1-09A.WATER CLOSET FIXTURES LOCATED IN ACCESSIBLE WATER CLOSET COMPARTMENTS SHALL BE POSITIONEDWITH A WALL OR PARTITION TO THE REAR AND TO ONE SIDE. THE CENTERLINE OF THE ACCESSIBLE WATERCLOSET SHALL BE 18" FROM THE SIDE WALL OR PARTITION.B.ACCESSIBLE WATER CLOSETS SHALL BE PROVIDED A CLEAR FLOOR SPACE AND MANEUVERING SPACE PERDETAILS 8 AND 9 ON THIS SHEET.C.THE SEAT HEIGHT OF A WATER CLOSET ABOVE FINISH FLOOR SHALL BE 17" MINIMUM AND 19" MAXIMUMMEASURED TO THE TOP OF THE SEAT. SEATS SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION. SEATSSHALL BE 2" HIGH MAXIMUM.D.GRAB BARS FOR WATER CLOSETS SHALL COMPLY WITH DETAIL 13 OF THIS SHEET. GRAB BARS SHALL BEPROVIDED ON THE SIDE WALL CLOSEST TO THE WATER CLOSET AND ON THE REAR WALL AS INDICATED BELOW.E.FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC. HAND OPERATED CONTROLS SHALL COMPLYWITH DETAIL 17 OF THIS SHEET EXCEPT THAT THEY SHALL BE LOCATED 44 INCHES MAXIMUM ABOVE THE FLOOR.F.TOILET PAPER DISPENSERS SHALL BE LOCATED AS INDICATED BELOW AND PER DETAIL 14 OF THIS SHEET.G.ACCESSIBLE WATER CLOSETS SHALL BE PROVIDED A CLEAR FLOOR SPACE AND MANEUVERING SPACE PERDETAILS 8 AND 9 ON THIS SHEET.48" MINIMUM <br />30" MINIMUMACCESSIBLE URINALS SHALL COMPLY WITH CBC SECTION 1127A.2.4 AND 11B-605.A.URINALS SHALL BE FLOOR MOUNTED (STALL TYPE) OR WALL HUNG WITH THE RIM 17" MAXIMUM ABOVE THEFINISH FLOOR OR GROUND. URINALS SHALL BE 13-1/2" DEEP MINIMUM MEASURED FROM THE OUTER FACE OFTHE URINAL RIM TO THE BACK OF THE FIXTURE.C.WHERE URINALS ARE PROVIDED, AT LEAST ONE SHALL HAVE A CLEAR FLOOR SPACE OF 30" X 48" IN FRONT OFTHE URINAL TO ALLOW FORWARD APPROACH. THE CLEAR FLOOR SPACE SHALL COMPLY WITH DETAIL 22 OFTHIS SHEET.D.FLUSH CONTROLS SHALL HAND OPERATED OR AUTOMATIC. HAND OPERATED FLUSH CONTROLS SHALLCOMPLY WITH DETAIL 17 OF THIS SHEET EXCEPT THAT THE FLUSH CONTROL SHALL BE MOUNTED AT AMAXIMUM HEIGHT OF 44" ABOVE FINISH FLOOR.13-1/2" MIN.17" MAX.13-1/2" MIN. <br />17" MAX. <br />17" MAX.SINGLE-ACCOMMODATION TOILET FACILITIES SHALL COMPLY WITH CBC SECTION 1127A.2.2 AND 11B-603.A.THERE SHALL BE SUFFICIENT SPACE IN THE TOILET ROOM FOR A WHEELCHAIR MEASURING 30" WIDE BY 48"LONG TO ENTER THE ROOM AND PERMIT THE DOOR TO CLOSE . THERE SHALL BE IN THE ROOM A CLEARFLOOR SPACE OF AT LEAST 60" IN DIAMETER, OR A T-SHAPED SPACE COMPLYING WITH DETAIL 22, NOTE B, OFTHIS SHEET; SEE FIGURES 9.1 AND 9.2 BELOW. NO DOOR SHALL NOT ENCROACH INTO THIS CLEAR FLOORSPACE FOR MORE THAN 12"; SEE FIGURE 9.2 BELOW.B.WHEN A TOILET ROOM OR BATHING ROOM IS FOR INDIVIDUAL USE AND A CLEAR FLOOR SPACE COMPLYINGWITH DETAIL 22, NOTE C, OF THIS SHEET, IS PROVIDED WITHIN THE ROOM BEYOND THE ARC OF THE DOORSWING, DOORS SHALL BE PERMITTED TO SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIREDFOR ANY FIXTURE; SEE FIGURE 9.2 BELOW.C.PROVIDE ONE ACCESSIBLE WATER CLOSET IN COMPLIANCE WITH THE REQUIREMENTS WITHIN THIS DETAILAND DETAIL 10 ON THIS SHEET. PROVIDE ONE LAVATORY IN COMPLIANCE WITH DETAIL 12 0F THIS SHEET.D.ALL DOORS FIXTURES AND CONTROLS SHALL BE ON AN ACCESSIBLE ROUTE. THE MINIMUM CLEAR WIDTH OFAN ACCESSIBLE ROUTE SHALL BE 36" EXCEPT AT DOORS. SEE DETAIL 4 OF THIS SHEET.E.THE ACCESSIBLE ROUTE AND TOILET ROOM FLOOR SHALL BE STABLE, FIRM AND SLIP RESISTANT.F.GRAB BARS SHALL BE INSTALLED IN COMPLIANCE WITH DETAILS 10 & 13 OF THIS SHEET.G.THE ENTRANCE DOOR SHALL BE PROVIDED WITH A PRIVACY LOCK OR LATCH IN COMPLIANCE WITH DETAIL 40F THIS SHEET.MULTIPLE-ACCOMMODATION TOILET FACILITIES SHALL COMPLY WITH CBC SECTIONS 1127A.2.1 AND 11B-604.A.TURNING SPACE OF SUFFICIENT SIZE TO INSCRIBE A CIRCLE WITH A DIAMETER NOT LESS THAN 60" OR AT-SHAPED SPACE SHALL BE PROVIDED WITHIN THE TOILET FACILITY. THE WHEECHAIR TURNING SPACE SHALLCOMPLY WITH SECTION 1138A.1.3. OTHER THAN THE DOOR TO THE ACCESSIBLE WATER CLOSET COMPARTMENT,A DOOR, IN ANY POSITION, MAY ENCROACH INTO THIS SPACE BY NOT MORE THAN 12".B.DOORS SHALL NOT SWING INTO THE FLOOR SPACE REQUIRED FOR ANY FIXTURE. REQUIRED CLEAR FLOORSPACE, CLEARANCE AT FIXTURES, AND TURNING SPACE SHALL BE PERMITTED TO OVERLAP. SEE FIGURE 8.2-BBELOW, ACCESSIBLE COMPARTMENT WITH SIDE IN-SWING DOOR.C.PROVIDE A MINIMUM OF ONE ACCESSIBLE WATER CLOSET IN COMPLIANCE WITH THE REQUIREMENTS WITHINTHIS DETAIL AND DETAIL 10 ON THIS SHEET. PROVIDE AT LEAST 5 PERCENT OF LAVATORIES, BUT NOT LESSTHAN ONE LAVATORY, SHALL BE ACCESSIBLE IN COMPLIANCE WITH DETAIL 12 0F THIS SHEET.D.WATER CLOSETS REQUIRED TO BE ACCESSIBLE SHALL COMPLY WITH THE FOLLOWING:1.THE CENTERLINE OF THE ACCESSIBLE WATER CLOSET SHALL BE 18" MAXIMUM FROM THE SIDE WALL ORPARTITION. THE CENTERLINE OF THE ACCESSIBLE WATER CLOSET LOCATED IN A AMBULATORY ACCESSIBLECOMPARTMENT, REQUIRED BY NOTE F BELOW, SHALL BE 18" FROM THE SIDE WALL OR PARTITION.2.PROVIDE A CLEAR FLOOR SPACE AND MANEUVERING SPACE IN COMPLIANCE WITH FIGURES 8.1A, 8.1B, 8.2AOR 8.2B AT THE ACCESSIBLE WATER CLOSET COMPARTMENT AND FIGURE 3 WHEN A AMBULATORYACCESSIBLE COMPARTMENT IS REQUIRED.E.ACCESSIBLE WATER CLOSET COMPARTMENT DOORS SHALL COMPLY WITH THE FOLLOWING:1.THE COMPARTMENT DOOR SHALL BE EQUIPPED WITH AN AUTOMATIC-CLOSING DEVISE, AND SHALL HAVE ACLEAR, UNOBSTRUCTED OPENING WIDTH OF 32" WHEN LOCATED AT THE END AND 34" WHEN LOCATED ATTHE SIDE WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION. SEE ALLFIGURES BELOW.2.THE INSIDE AND OUTSIDE OF THE COMPARTMENT DOOR SHALL BE EQUIPPED WITH A LOOP OR U-SHAPEDHANDLE IMMEDIATELY BELOW THE LATCH. THE LATCH SHALL BE FLIP-OVER STYLE, SLIDING OR OTHERHARDWARE NOT REQUIRING THE USER TO GRASP OR TWIST.3.EXCEPT FOR DOOR-OPENING WIDTHS AND DOOR SWINGS, A CLEAR, UNOBSTRUCTED ACCESS OF NOT LESSTHAN 44 INCHES SHALL BE PROVIDED TO WATER CLOSET COMPARTMENTS DESIGNED FOR USE BY PERSONSWITH DISABILITIES, AND THE SPACE IMMEDIATELY IN FRONT OF A WATER CLOSET COMPARTMENT SHALL NOTBE LESS THAN 48 INCHES AS MEASURED AT RIGHT ANGLES TO COMPARTMENT DOOR IN ITS CLOSEDPOSITION. MANEUVERING SPACE OUTSIDE THE COMPARTMENT DOOR SHALL COMPLY WITH DETAIL 4, NOTEF, OF THIS SHEET. MANEUVERING SPACE INSIDE THE COMPARTMENT SHALL COMPLY WITH THE THE FIGURESBELOW.4.TOE CLEARANCE SHALL BE PROVIDED ON AT LEAST ONE SIDE PARTITION OF AT LEAST 9" HIGH AND 6" DEEPMEASURED FROM THE COMPARTMENT-SIDE FACE OF THE PARTITION, EXCLUSIVE OF PARTITION SUPPORTMEMBERS. PARTITION COMPONENTS AT TOE CLEARANCES SHALL BE SMOOTH WITHOUT SHARP EDGES ORABRASIVE SURFACES. TOE CLEARANCE IS NOT REQUIRED IN COMPARTMENTS GREATER THAN 66" WIDE.F.IN LARGE TOILET ROOMS, WHERE SIX OR MORE STALLS ARE PROVIDED WITHIN A MULTIPLE- ACCOMMODATIONTOILET ROOM, IN ADDITION TO THE WATER CLOSET COMPARTMENT REQUIRED ABOVE, PROVIDE AT LEAST ONEAMBULATORY ACCESSIBLE COMPARTMENT. THE AMBULATORY ACCESSIBLE COMPARTMENT SHALL BE 36" WIDEWITH AN OUTWARD SWINGING SELF-CLOSING DOOR AND PARALLEL GRAB BARS COMPLYING WITH DETAIL 13 OFTHIS SHEET INSTALLED ON EACH SIDE WALL OF THE COMPARTMENT. SEE FIGURE 8.3 BELOW.COMMON ACCESSIBLE LAUNDRY ROOMS SHALL COMPLY WITH CBC SECTIONS 1127A.10 AND 11B-611WHERE COMMON USE LAUNDRY ROOMS ARE PROVIDED, AT LEAST ON TYPE OF APPLIANCE PROVIDED IN EACHLAUNDRY AREA SHALL BE ACCESSIBLE AND SHALL BE ON AN ACCESSIBLE ROUTE. SUCH APPLIANCES SHALLINCLUDE CLOTHES WASHING MACHINES, DRYERS, SOAP DISPENSERS AND ANY RELATED FEATURES SUCH ASWASH SINKS, TABLES AND STORAGE AREAS.WHERE LAUNDRY ROOMS ARE PROVIDED ON FLOORS OF AN ELEVATOR BUILDING, EACH LAUNDRY ROOM SHALLBE ACCESSIBLE. WHERE THERE IS ONE LAUNDRY ROOM ON A GROUND FLOOR IN EACH BUILDING, EACH LAUNDRYROOM SHALL BE ACCESSIBLE. WHERE THERE IS A LAUNDRY ROOM ON THE GROUND FLOOR OF A BUILDING ANDANOTHER LOCATED IN A BASEMENT, IT IS ACCEPTABLE TO ONLY HAVE THE GROUND FLOOR LAUNDRYACCESSIBLE.A.THERE SHALL BE A MINIMUM CLEAR SPACE 30" PERPENDICULAR BY 48" PARALLEL IN FRONT OF CLOTHESWASHERS AND DRYERS REQUIRED TO BE ACCESSIBLE. THERE SHALL BE A MINIMUM CLEAR SPACE 30" BY 48"PROVIDED FOR AT LEAST ONE TYPE OF FIXTURE OR APPLIANCE PROVIDED IN THE LAUNDRY ROOM (E.G.,SOAP DISPENSERS, WASH SINKS, TABLES AND STORAGE AREAS).B.CLOTHES WASHERS AND DRYERS INCLUDING STACKED CLOTHES WASHERS AND DRYERS REQUIRED TO BEACCESSIBLE SHALL HAVE CONTROLS (INCLUDING COIN SLOTS) WITHIN THE REACH RANGE OF A SEATEDUSER. CONTROLS SHALL BE LOCATED NO HIGHER THAN 48" AND NO LOWER THAN 15", ABOVE THE FINISHFLOOR MEASURED TO THE CENTER OF THE GRIP. IF THE REACH IS OVER AN OBSTRUCTION (FOR EXAMPLE, AWASHER OR DRYER) BETWEEN 20" AND 25" IN DEPTH, THE MAXIMUM HEIGHT IS REDUCED TO 44" FORFORWARD APPROACH, OR 46" FOR SIDE APPROACH, PROVIDED THAT THE OBSTRUCTION IS NO MORE THAN24" IN DEPTH. CONTROLS THAT DO NOT SATISFY THESE SPECIFICATIONS ARE ACCEPTABLE, PROVIDED THATCOMPARABLE CONTROLS OR OUTLETS, THAT PROVIDE THE SAME FUNCTIONS, ARE PROVIDED WITHIN THESAME AREA AND ARE ACCESSIBLE. CONTROLS SHALL BE OPERABLE WITH ONE HAND AND NOT REQUIRETIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. SEE DETAIL 22 ON THIS SHEET.C.WASHING MACHINES AND CLOTHES DRYERS IN ACCESSIBLE COMMON USE LAUNDRY ROOMS SHALL BEFRONT LOADING.D.DEEP UTILITY SINKS SHALL MEET THE REQUIREMENTS FOR FAUCET CONTROLS (SEE DETAIL 12 THIS SHEET)AND A 30"X48" CLEAR FLOOR SPACE PARALLEL TO THE SINK SHALL BE PROVIDED.E.FOLDING TABLES SHALL BE PROVIDED WITH THE TABLE TOP BETWEEN 28" TO 34" ABOVE THE FLOOR. KNEESPACE SHALL BE PROVIDED BELOW IN COMPLIANCE WITH DETAIL 12 THIS SHEET.17"-19"THIS SHEET IS FOR REFERENCE ONLY AND ILLUSTRATES CODE-REQUIRED MINIMUM STANDARDS FOR COMMONAND PUBLIC USE FACILITIES WITHIN A MULTIFAMILY DEVELOPMENT. SEE PERTINENT SHEETS, DRAWINGS, ANDSPECIFICATIONS FOR APPLICATION OF THESE STANDARDS TO THIS SPECIFIC PROJECT.THE INFORMATION CONTAINED WITHIN THESE SHEETS ARE EXCERPTS FROM THE CALIFORNIA BUILDING CODE(CBC) AND FAIR HOUSING ACT (FHA) DESIGN MANUAL, AND INTENDED TO PROVIDED THE CONTRACTOR THEGENERAL REQUIREMENTS OF ACCESSIBILITY FOR THIS PROJECT. THE GENERAL CONTRACTOR SHALL BEKNOWLEDGEABLE OF AND SHALL BUILD TO ALL APPLICABLE ACCESSIBILITY CODE REQUIREMENTS, IF FURTHERINFORMATION OR CLARIFICATION IS REQUIRED, CONSULT THE ARCHITECT OR REFERENCE THE CBC AND FHADESIGN MANUAL PRIOR TO FABRICATION OR INSTALLATION OF THE WORK.COMMON USE FACILITIES SHALL COMPLY WITH CBC CHAPTER 11A AND ANSI A117.1 AS REFERENCED BY THE FAIRHOUSING ACT (FHA) DESIGN MANUAL. IF COMMON USE FACILITIES ARE MADE AVAILABLE TO THE PUBLIC, IF ONLYPERIODICALLY, THEY MUST COMPLY WITH CBC CHAPTER 11B AND ADAS N ADDITION TO THE REQUIREMENTS LISTEDABOVE DURING PERIODS OF PUBLIC USE.WHEN PROVIDED, COMMON USE AREAS AND FACILITIES IN COVERED MULTIFAMILY DEVELOPMENTS SHALL BEACCESSIBLE TO PERSONS WITH DISABILITIES. COMMON USE FACILITIES INCLUDE, BUT ARE NOT LIMITED TO;LOBBIES, TOILET AND BATHING FACILITIES, LAUNDRY FACILITIES,COMMUNITY ROOMS, CLUBHOUSES, HEALTH ANDFITNESS FACILITIES, GAME ROOMS AND PORTIONS OF COMMON USE TENANT STORAGE. ALL ENTRANCES, DOORS,FIXTURES AND CONTROLS SHALL BE ON AN ACCESSIBLE ROUTE.PUBLIC USE FACILITIES AND AREAS SHALL COMPLY WITH CBC CHAPTER 11B AND ADAS. WHEN PROVIDED, PUBLICUSE FACILITIES AND AREAS FACILITIES IN COVERED MULTIFAMILY DEVELOPMENTS SHALL BE ACCESSIBLE TOPERSONS WITH DISABILITIES.PUBLIC USE FACILITIES INCLUDE, BUT ARE NOT LIMITED TO; RENTAL OFFICES, SALES OFFICES AND MAINTENANCEFACILITIES. THESE AREAS, BY THEIR NATURE, ARE OPEN TO PEOPLE OTHER THAN RESIDENTS AND THEIR GUESTS.THEY, THEREFORE, MUST COMPLY.DOORS THAT PROVIDE ACCESS TO COMMON USE AREAS SHALL COMPLY WITH SECTION 1126A AND 11B-404. THIS SHEET FORLANDINGS AND THRESHOLDS. THE COMMON USE OR PUBLIC SIDE OF PRIMARY ACCESS DOORS TO DWELLING UNITS SHALLCOMPLY WITH NOTES F AND G BELOW.A.DOORWAYS SHALL PERMIT THE INSTALLATION OF A DOOR NOT LESS THAN 36" IN WIDTH, NOT LESS THAN 80" IN HEIGHTAND PROVIDE A CLEAR OPENING OF NOT LESS THAN 32" IN WIDTH, MEASURED WITH THE DOOR OR DOORS POSITIONEDAT AN ANGLE OF 90-DEGREES FROM THE CLOSED POSITION.B.DOORS SHALL BE CAPABLE OF OPENING AT LEAST 90 DEGREES..C.A PAIR OF DOORS, MANUAL OR AUTOMATIC, MUST HAVE AT LEAST ONE LEAF THAT PROVIDES A CLEAR WIDTH OF NOTLESS THAN 32", MEASURED WITH THE DOOR POSITIONED AT AN ANGLE OF 90-DEGREES FROM ITS CLOSED POSITION.AT DOUBLE EGRESS DOORS EACH LEAF MUST PROVIDE THE CLEAR WIDTH.D.THE WIDTH OF ANY COMPONENT OF THE EGRESS SYSTEM SHALL NOT BE LESS THAN THE MINIMUM WIDTH REQUIREDBY SECTION 1005.E.PER CBC SECTION 1010.1.5, THERE SHALL BE A FLOOR OR LANDING ON EACH SIDE OF THE DOOR. SUCH FLOOR ORLANDING SHALL BE THE SAME ELEVATION ON EACH SIDE OF THE DOOR. LANDINGS SHALL BE LEVEL EXCEPT FOREXTERIOR LANDINGS, WHICH ARE PERMITTED TO HAVE A SLOPE NOT TO EXCEED 1/4" VERTICAL TO 12" HORIZONTAL(2-PERCENT SLOPE). SEE DETAIL 6 FOR ADDITIONAL INFORMATION.F.MANEUVERING CLEARANCES AT DOORS1.THE LEVEL FLOOR OR LANDING OF AN EXIT DOOR SHALL HAVE A LENGTH IN THE DIRECTION OF THE DOOR SWINGOF AT LEAST 60" AND A LENGTH OPPOSITE OF THE DOOR SWING OF AT LEAST 44" MEASURED AT RIGHT ANGLES TOTHE PLANE OF THE DOOR IN ITS CLOSED POSITION. SEE FIGURES BELOW.2.THE WIDTH OF LEVEL AREA ON THE SIDE TO WHICH THE DOOR SWINGS SHALL EXTEND AT LEAST 18" PAST THESTRIKE EDGE OF THE DOOR FOR INTERIOR DOORS AND AT LEAST 24" PAST THE STRIKE EDGE OF THE DOOR FOREXTERIOR DOORS.3.THE FOLLOWING PROVISIONS SHALL APPLY TO SWINGING DOORS WITH A FRONT APPROACH:4.THE FOLLOWING PROVISIONS SHALL APPLY TO SWINGING DOORS WITH A HINGE SIDE APPROACH:5.THE FOLLOWING PROVISIONS SHALL APPLY TO SWINGING DOORS WITH A LATCH SIDE APPROACH:6.THE FOLLOWING PROVISIONS SHALL APPLY TO SWINGING DOORS INSTALLED IN A SERIES:G.MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 8 1/2 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FORINTERIOR DOORS, SUCH PULL OR PUSH EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGED DOORS AND AT THECENTER PLANE OF SLIDING OR FOLDING DOORS. COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BEUTILIZED TO MEET THESE STANDARDS. WHEN FIRE DOORS ARE REQUIRED, THE MAXIMUM EFFORT TO OPERATE THEDOOR MAY BE INCREASED TO THE MINIMUM ALLOWABLE BY THE APPROPRIATE ENDORSEMENT AGENCY, NOT TOEXCEED 15 POUNDS.H.IF THE DOOR HAS A CLOSURE, THEN THE SWEEP PERIOD OF THE CLOSER SHALL BE ADJUSTED SO THAT FROM AN OPENPOSITION OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3 INCHES FROM THELATCH, MEASURED TO THE LANDING EDGE OF THE DOOR.I.THE TYPE OF LATCH AND LOCK FOR ALL DOORS SHALL BE IN ACCORDANCE WITH CBC SECTION 1008.J.HAND-ACTIVATED DOOR LATCHING, LOCKING AND OPENING HARDWARE SHALL BE CENTERED BETWEEN 30" AND 44"ABOVE THE FLOOR. LATCHING AND LOCKING DOORS THAT ARE HAND-ACTIVATED AND ON AN ACCESSIBLE ROUTESHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARSOR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE HARDWARE.LOCKED EXIT DOORS SHALL OPERATE CONSISTENT WITH NOTE H ABOVE, IN THE DIRECTION OF EGRESSK.LEVER OR LEVER ACTUATED LATCHES OR LOCKS SHALL BE CURVED TO RETURN TO WITHIN 1/2" OF THE DOOR TOPREVENT CATCHING OF CLOTHING OF PERSONS DURING EGRESS.L.THE BOTTOM 10" OF ALL DOORS AND/OR GATES SHALL HAVE A SMOOTH, UNINTERRUPTED SURFACE TO ALLOW THEDOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. WHERENARROW FRAME DOORS ARE USED, A 10" HIGH SMOOTH PANEL SHALL BE INSTALLED ON THE PUSH SIDE OF THE DOOR.MAT CARPETING MUST CONSIST OF:A.LEVEL LOOPB.TEXTURED LOOPC.LEVEL CUT PILED.LEVEL CUT/UNCUT PILECOMPRESSED CARPET 1/2"MAX. BELOW THRESHOLDFINISH FLOOR EVENDOOR THRESHOLDDOOR LANDINGSA.THE FLOOR OR LANDING ON EACH SIDE OF AN EXIT DOOR SHALL BE LEVEL.DOOR THRESHOLDSA.THRESHOLDS AND CHANGES IN ELEVATION AT DOORS SHALL NOT BE MORE THAN 1/2" LOWER THAN THE TOPOF THE THRESHOLD OF THE DOORWAY.B.THRESHOLDS WITH A CHANGE IN HEIGHT OF NOT MORE THAN 1/4" MAY BE VERTICAL.C.CHANGES IN LEVEL BETWEEN 1/4" AND 1/2" SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1 VERTICALUNIT TO 2 UNITS HORIZONTAL. CHANGES GREATER THAN 1/2" SHALL BE ACCOMPLISHED BY MEANS OF A RAMP.DOOR MATSA.IF A DOORMAT IS USED IN A COMMON-USE AREA OR PUBLIC-USE AREA, IT SHALL HAVE A FIRM BACKING OR NOBACKING.B.THE MAXIMUM PILE HEIGHT SHALL BE 1/2".C.EXPOSED EDGES OF THE DOORMAT SHALL BE FASTENED TO THE FLOOR SURFACE AND HAVE TRIM ALONGTHE ENTIRE LENGTH OF EXPOSED EDGES THAT SHALL COMPLY WITH THE REQUIREMENTS FOR CHANGES INLEVEL;1.CHANGES IN LEVEL SHALL NOT EXCEED 1/2".2.WHEN CHANGES IN LEVEL DO OCCUR, THEY SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1UNIT VERTICAL IN 2 UNITS HORIZONTAL (50% SLOPE).3.CHANGES IN LEVEL NOT EXCEEDING 1/4" MAY BE VERTICAL.4.CHANGES IN LEVEL GREATER THAN 1/2" SHALL BE MADE BY MEANS OF A SLOPED SURFACE WITH ASLOPE NOT GREATER THAN 1 UNIT VERTICAL IN 20 UNITS HORIZONTAL (5% SLOPE).D.RECESSED DOOR MATS SHALL BE LEVEL WITH THE ADJACENT SURFACE AND BE ADEQUATELY ANCHORED TOPREVENT INTERFERENCE WITH WHEELCHAIR TRAFFIC.LANDINGS AND THRESHOLDS SHALL COMPLY WITH CBC SECTIONS 1010.1.6, 1010.1.7, 1126A.2 AND 11B-302, 11B-303INTERIOR MATERIAL CHANGESA.MATERIAL CHANGES IN HEIGHT AT INTERIOR DOOR THRESHOLDS SHALL NOT EXCEED 1/2".B.THRESHOLDS WITH A CHANGE IN HEIGHT OF NOT MORE THAN 1/4" MAY BE VERTICAL.121/4" MAX. <br />RISE <br />1/2" MAX. <br />BEVEL <br />BEVEL12BEVEL2% MAXIMUM SLOPEAT EXTERIOR LANDINGACCESSIBLE LAVATORIES SHALL COMPLY WITH CBC SECTIONS 1127A.3, 1138A.2 AND 11B-606.LAVATORY FIXTURES, VANITIES AND BUILT-IN LAVATORIES SHALL COMPLY WITH THE FOLLOWING:A.LAVATORIES, WHEN LOCATED ADJACENT TO A SIDE WALL OR PARTITION, SHALL BE A MINIMUM OF 18" TO THECENTERLINE OF THE FIXTURE. ALL LAVATORIES DESIGNATED TO BE ACCESSIBLE SHALL BE A MINIMUM 17" INHORIZONTAL DEPTH AND MOUNTED WITH THE RIM OR COUNTER EDGE NO HIGHER THAN 34" ABOVE THEFINISH FLOOR AND WITH VERTICAL CLEARANCE MEASURED FROM THE BOTTOM APRON OR OUTSIDEBOTTOM EDGE OF THE LAVATORY OF 29" REDUCING TO 27" AT A POINT LOCATED 8" BACK FROM THE FRONTEDGE. IN ADDITION, A MINIMUM 9" HIGH TOE CLEARANCE MUST BE PROVIDED EXTENDING BACK TOWARD THEWALL TO A DISTANCE NO MORE THEN 6" FROM THE BACK WALL. THE TOE CLEARANCE SPACE MUST BE FREEOF EQUIPMENT AND OBSTRUCTIONS; SEE FIGURE B BELOW.B.A CLEAR FLOOR SPACE 30" BY 48" COMPLYING WITH THE FIGURES BELOW AND DETAIL 22, NOTE D, OF THISSHEET SHALL BE PROVIDED IN FRONT OF AND CENTERED ON ACCESSIBLE LAVATORIES TO ALLOW FORWARDAPPROACH. SUCH CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE AND SHALL NOTEXTEND INTO THE KNEE AND TOE SPACE UNDERNEATH THE LAVATORY MORE THAN 19". THIS CLEAR SPACESHALL COMPLY WITH ALLOWABLE REACH RANGES.C.THE FLOOR FINISH BENEATH THE LAVATORY SHALL EXTEND TO THE WALL.D.HOT WATER & DRAIN PIPES EXPOSED UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE COVERED.THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES.E.LAVATORY FAUCET CONTROLS AND OPERATION MECHANISMS SHALL BE OPERABLE WITH ONE HAND ANDSHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE TO ACTIVATECONTROLS SHALL BE NO GREATER THAN 5 POUND-FORCE. LEVER OPERATED, PUSH-TYPE, ANDELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS. SELF-CLOSINGVALVES ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS.F.WHERE MIRRORS OR TOWEL FIXTURES ARE PROVIDED, AT LEAST ONE OF EACH SHALL BE ACCESSIBLE ANDSHALL BE MOUNTED WITH THE BOTTOM EDGE NO HIGHER THAN 40" FROM THE FLOOR. SEE DETAIL14 0N THISSHEET FOR ADDITIONAL INFORMATION.60" MIN. FINISH TO FINISH CLEARSPACE ALLOWANCES AND REACH RANGES SHALL COMPLY WITH CBC SECTIONS 1138A, 11B-DIVISION 3 & 11B-DIVISION 4.A.WHEELCHAIR PASSAGE AND PASSING WIDTHS THE MINIMUM CLEAR WIDTH FOR WHEELCHAIR PASSAGE IS 36"CONTINUOUSLY. A 32" WIDTH IS ACCEPTABLE AT A POINT NOT TO EXCEED 24" IN LENGTH, SEE FIGURE 1. SEE FIGURE 2.FOR THE MINIMUM WIDTH FOR TWO WHEELCHAIRS TO PASS IS 60".B.WHEELCHAIR TURNING SPACE SHALL COMPLY WITH ONE OF THE FOLLOWING FIGURES:C.CLEAR FLOOR OR GROUND SPACE FOR WHEELCHAIRS. SHALL COMPLY WITH THE FOLLOWING:1.SIZE AND APPROACH THE MINIMUM CLEAR FLOOR OR GROUND SPACE REQUIRED TO ACCOMMODATE A SINGLEWHEELCHAIR IS 30" BY 48". THE CLEAR FLOOR SPACE FOR WHEEL CHAIRS MAY BE POSITIONED FOR FORWARD ORPARALLEL APPROACH TO AN OBJECT U.N.O.. THE CLEAR FLOOR OR GROUND SPACE FOR WHEELCHAIRS MAY BE APART OF THE KNEE SPACE REQUIRED UNDER SOME OBJECTS.2.RELATIONSHIP OF MANEUVERING CLEARANCES TO WHEELCHAIR SPACES ONE FULL UNOBSTRUCTED SIDE OF THECLEAR FLOOR OR GROUND SPACE FOR A WHEELCHAIR SHALL ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE ORADJOIN ANOTHER WHEELCHAIR CLEAR FLOOR OR GROUND SPACE. IF A CLEAR FLOOR SPACE IS LOCATED IN ANALCOVE OR OTHERWISE CONFINED ON ALL OR PART OF THREE SIDES, ADDITIONAL MANEUVERING CLEARANCESSHALL BE PROVIDED AS FOLLOWS:D.SURFACES FOR WHEELCHAIR SPACES GROUND AND FLOOR SURFACES ALONG ACCESSIBLE ROUTES, AND INACCESSIBLE ROOMS AND SPACES, INCLUDING FLOORS, WALKS, RAMPS ,STAIRS AND CURB RAMPS SHALL BE STABLE,FIRM, SLIP RESISTANT AND SHALL COMPLY WITH THE FOLLOWING:1.CHANGES IN LEVEL, UP TO 1/4" MAY BE VERTICAL AND WITHOUT EDGE TREATMENT. CHANGES IN LEVEL BETWEEN1/4" AND 1/2" SHALE BE BEVELED WITH A SLOPE NO GREATER THAN 1 UNIT VERTICAL IN 2 UNITS HORIZONTAL.CHANGES IN LEVEL GREATER THAN 1/2"MUST BE ACCOMPLISHED BY MEANS OF A RAMP, ELEVATOR OR PLATFORMLIFT.2.IF CARPET OR CARPET TILE IS USED ON A GROUND OR FLOOR SURFACE, IT SHALL BE SECURELY ATTACHED; HAVEFIRM CUSHION, PAD OR BACKING OR NO CUSHION, PAD OR BACKING; AND HAVE A LEVEL LOOP, TEXTURED LOOP,LEVEL-CUT PILE, OR LEVEL-CUT/UNCUT PILE TEXTURE. THE MAXIMUM PILE HEIGHT SHALL BE 1/2". EXPOSED EDGESOF THE CARPET SHALL BE FASTENED TO THE FLOOR SURFACES AND HAVE TRIM ALONG THE ENTIRE LENGTH OFTHE EXPOSED EDGE. CARPET EDGE TRIM SHALL COMPLY WITH ITEM 1 ABOVE3.ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALL NOT EXCEED 1/2". WHEN CHANGES IN LEVELDO OCCUR, THEY SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1 UNIT VERTICAL IN 2 UNITS HORIZONTAL.CHANGES IN LEVEL NOT EXCEEDING 1/4" MAY BE VERTICAL.4.IF GRATINGS ARE LOCATED IN WALKING SURFACES, THEN THEY SHALL BE LIMITED TO SPACES NO GREATER THAN1/2" WIDE IN ONE DIRECTION . IF GRATINGS HAVE ELONGATED OPENINGS, THEY SHALL BE PLACED SO THAT THELONG DIMENSION IS PERPENDICULAR TO THE DOMINATE DIRECTION OF TRAVEL.E.REACH RANGES SHALL COMPLY WITH THE FOLLOWING FIGURES:* THE TOP OF WASHING MACHINES AND CLOTHES DRYERS ARE PERMITTED TO BE 36" MAXIMUM ABOVE THE FINISH FLOOR.GRAB BARS, TUB AND SHOWER SEATS SHALL COMPLY WITH CBC SECTIONS 1127A.4.A.GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION, 33" MINIMUM AND 36" MAXIMUM ABOVE THE FINISHFLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE.EXCEPTION: THE HEIGHT OF THE LOWER GRAB BAR ON THE BACK WALL OF A BATHTUB SHALL COMPLY WITHSECTION 1127A.5.2.B.THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A GRAB BAR SHALL COMPLY WITH THE FOLLOWING: 1. GRAB BARS WITH CIRCULAR CROSS SECTION SHALL HAVE AN OUTSIDE DIAMETER OF 1 14". 2. GRAB BARS WITH NON-CIRCULAR CROSS SECTION SHALL HAVE A CROSS- SECTION DIMENSION OF 2" MAXIMUM. THE PERIMETER DIMENSION OF GRAB BARS WITH NON-CIRCULAR CROSS SECTION SHALL BE 4" MINIMUM AND AND 4.8" MAXIMUM. 3. L-SHAPED OR U-SHAPED GRAB BARS SHALL BE PERMITTED.C.THE STRUCTURAL STRENGTH OF GRAB BARS, TUB AND SHOWER SEATS, FASTENERS AND MOUNTING DEVISES SHALLMEET THE FOLLOWING SPECIFICATIONS:1.BENDING STRESS IN A GRAB BAR OR SEAT INDUCED BY THE MAXIMUM BENDING MOMENT FROM THE APPLICATIONOF A 250-POUND POINT LOAD SHALL BE LESS THAN THE ALLOWABLE STRESS FOR THE MATERIAL OF THE GRAB BAROR SEAT.2.SHEAR STRESS INDUCED IN A GRAB BAR OR SEAT BY THE APPLICATION OF A 250-POUND POINT LOAD SHALL BELESS THAN THE ALLOWABLE SHEAR STRESS FOR THE MATERIAL OF THE GRAB BAR OR SEAT, AND IF ITS MOUNTINGBRACKET OR OTHER SUPPORT IS CONSIDERED TO BE FULLY RESTRAINED, THEN DIRECT OR TORSIONAL SHEARSTRESSES SHALL NOT EXCEED THE ALLOWABLE SHEAR STRESS.3.SHEAR FORCE INDUCED IN A FASTENER OR MOUNTING DEVICE FROM THE APPLICATION OF A 250-POUND POINTLOAD SHALL BE LESS THAN THE ALLOWABLE LATERAL LOAD OF EITHER THE FASTENER OR MOUNTING DEVICE ORTHE SUPPORTING STRUCTURE, WHICHEVER IS THE SMALLER LOAD.4.TENSILE FORCE INDUCED BY A FASTENER BY A DIRECT TENSION FORCE OF A 250-POUND POINT LOAD PLUS THEMAXIMUM MOMENT FROM THE APPLICATION OF A 250-POUND POINT LOAD, SHALL BE LESS THAN THE ALLOWABLEWITHDRAWAL LOAD BETWEEN THE FASTENER AND THE SUPPORTING STRUCTURE.5.GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS.C.A GRAB BAR AND ANY WALL OR OTHER SURFACE ADJACENT TO IT SHALL BE FREE OF ANY SHARP OR ABRASIVEELEMENTS AND SHALL HAVE ROUNDED EDGES.D.ADJACENT ELEMENTS, FOR EXAMPLE WATER CLOSET FLUSH VALVES, SHALL BE POSITIONED TO PROVIDEUNOBSTRUCTED USE OF THE GRAB BARS AT THE SPECIFIED LOCATIONS. THE SPACE BETWEEN THE GRAB BAR ANDPROJECTING OBJECTS BELOW AND AT THE ENDS SHALL BE 1 1/2" MINIMUM. THE SPACE BETWEEN THE GRAB BAR ANDPROJECTING OBJECTS ABOVE SHALL BE 12" MINIMUM.1.THE SPACE BETWEEN THE GRAB BARS AND SHOWER CONTROLS, SHOWER FITTINGS, AND OTHER GRAB BARSABOVE SHALL BE PERMITTED TO BE 1 1/2" MINIMUM.1 1/2" MINGRAB BAR 1 1/4" TO2" NOMINAL DIAM.FIGURE 8.2-AACCESSIBLE COMPARTMENT WITHSIDE OUT-SWING DOORPUSH SIDE60" MIN STORAGE SHALL COMPLY WITH CBC SECTIONS 1127A.11 AND 11B-811.IF FIXED STORAGE FACILITIES SUCH AS CABINETS AND SHELVES, CLOSETS AND DRAWERS ARE PROVIDED WHERE ACCESSIS REQUIRED (BY CBC SECTIONS 1.8.2.1.2 AND 1102A), AT LEAST ONE OF EACH TYPE OF FACILITY PROVIDED SHALL COMPLYWITH THE FOLLOWING ITEMS. ADDITIONAL STORAGE MAY BE PROVIDED OUTSIDE OF THE REACH RANGES.A. A CLEAR FLOOR SPACE AT LEAST 30" BY 48" COMPLYING WITH CBC SECTION 1138A.14 THAT ALLOWS EITHER AFORWARD OR PARALLEL APPROACH BY A PERSON USING A WHEELCHAIR SHALL BE PROVIDED AT ACCESSIBLESTORAGE FACILITIES.B.ACCESSIBLE STORAGE SPACES AND CLOTHES RODS SHALL BE WITHIN AT LEAST ONE OF THE REACH RANGESSPECIFIED IN SECTION 1138A.3.C.HARDWARE FOR ACCESSIBLE STORAGE FACILITIES SHALL COMPLY WITH CBC SECTION 1138A.4. TOUCH LATCHESAND U-SHAPED PULLS ARE ACCEPTABLE.FIXED OR BUILT-IN SEATING , TABLES AND COUNTERS SHALL COMPLY WITH CBC SECTIONS 1127A.12 AND 1122B.WHERE FIXED OR BUILT-IN SEATING, TABLES OR COUNTERS ARE PROVIDED IN ACCESSIBLE PUBLIC USE OR COMMON USEAREAS, 5 PERCENT, BUT NEVER LESS THAN ONE, SHALL BE ACCESSIBLE AS FOLLOWS:A.ACCESSIBLE ROUTE OF TRAVEL. A ROUTE OF TRAVEL SHALL LEAD TO AND THROUGH SUCH FIXED OR BUILT-INSEATING AREAS OR TABLES.B.SEATING. IF SEATING SPACES FOR PERSONS IN WHEELCHAIRS ARE PROVIDED AT FIXED TABLES OR COUNTERS,CLEAR FLOOR SPACE SHALL BE PROVIDED PER DETAIL 22 ON THIS SHEET. SUCH CLEAR FLOOR SPACE SHALL NOTOVERLAP KNEE SPACE BY MORE THAN 19".C.KNEE CLEARANCE. WHEN SEATING SPACES FOR PERSONS IN WHEELCHAIRS ARE PROVIDED AT FIXED TABLES ORCOUNTERS, KNEE SPACES AT LEAST 27" HIGH SHALL COMPLY WITH THE FOLLOWING FIGURES:KNEE SPACE IS NOT REQUIRED AT CHECKOUT COUNTERS OR SERVICE COUNTERS.D.HEIGHT OF WORK SURFACES. THE TOPS OF TABLES AND COUNTERS SHALL BE 28" TO 34" FROM THE FLOOR TO THEGROUND.PULL SIDETOILET ROOM FIXTURES AND ACCESSORIES. SHALL COMPLY WITH CBC SECTIONS 1127A.8, 11B-603 & 11B-604A.TOWEL, SANITARY NAPKINS, WASTE RECEPTACLES. WHERE TOWEL, SANITARY NAPKINS, WASTERECEPTACLES AND OTHER SIMILAR DISPENSING AND DISPOSAL FIXTURES ARE PROVIDED, AT LEAST ONE OFEACH TYPE SHALL BE LOCATED WITH ALL OPERABLE PARTS, INCLUDING COIN SLOTS, WITHIN 40" FROMFINISHED FLOOR. A PATH OF TRAVEL NOT LESS THAN 36" IN CLEAR WIDTH SHALL BE PROVIDED TO THESEACCESSORIES.B.TOILET PAPER DISPENSERS. SEE DETAIL 10 OF THIS SHEET. SHALL BE LOCATED ON A WALL OR PARTITIONCLOSEST TO THE WATER CLOSET WITHIN 7" MINIMUM AND 9" MAXIMUM IN FRONT OF THE WATER CLOSETMEASURED FROM THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE DISPENSER SHALL BE BELOWAND NOT BEHIND THE GRAB BAR, 19" MINIMUM ABOVE THE FINISH FLOOR. DISPENSERS SHALL NOT BE OF ATYPE THAT CONTROLS DELIVERY OR THAT DOES NOT ALLOW CONTINUOUS PAPER FLOW.C.MIRRORS. WHERE PROVIDED, AT LEAST ONE MIRROR SHALL BE ACCESSIBLE. MIRRORS LOCATED ABOVELAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTINGSURFACE 40" ABOVE THE FINISH FLOOR OR GROUND. MIRRORS NOT LOCATED ABOVE LAVATORIES ORCOUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING SURFACE 35" MAXIMUMABOVE THE FINISH FLOOR.D.COAT HOOKS, SHELVES AND MEDICINE CABINETS. COAT HOOKS SHALL BE LOCATED WITHIN ONE OF THEREACH RANGES IDENTIFIED ON DETAIL 22 ON THIS SHEET. SHELVES SHALL BE LOCATED 40" MINIMUM AND48" MAXIMUM ABOVE THE FINISH FLOOR. MEDICINE CABINETS SHALL BE LOCATED WITH A USABLE SHELF NOHIGHER THAN 44" MAXIMUM ABOVE FINISH FLOOR.E.SPACES ALLOWANCES AND REACH RANGES IN COMMON USE AREAS. SEE DETAIL 22 ON THIS SHEET FOR THEREQUIRED CLEAR SPACE, ALLOWABLE REACH RANGES AND REQUIREMENTS FOR CONTROLS ANDOPERATING MECHANISMS.48" <br />MINIMUM <br />PUSH SIDE12"MINADDITIONAL MANEUVERING SPACE IF A DOORIS PROVIDED WITH BOTH CLOSER AND LATCH44" MIN36" MIN48" MIN <br />22"MIN24"MINPULL SIDEPUSH SIDE24"MIN48" MIN <br />44" MINDOORWIDTH <br />DOORWIDTHDOORWIDTHDOORWIDTHDOORWIDTHDOORWIDTH1/4" MAX. <br />BEVELFIGURE 8.3AMBULATORY ACCESSIBLE COMPARTMENT WITH FRONT OUT-SWING DOOR36" MIN.WHEN DR.SWINGS INFIGURE 8.2-BACCESSIBLE COMPARTMENT WITHSIDE IN-SWING DOOR59" MIN. ATFLR. MTD. W.C.OR 56" MIN. ATWALL MTD. W.C.CLR. FLR. SPACE60" MIN. DOOR <br />MANEUVERING & <br />CLR. FLR. SPACE <br />32" MIN <br />CLEAR <br />32" MIN <br />CLEAR <br />60" MIN <br />CLEAR <br />59" MIN. ATFLR. MTD. W.C.OR 56" MIN. ATWALL MTD. W.C.CLR. FLR. SPACE48" <br />CLEAR <br />48" <br />CLEAR <br />48" <br />CLEAR <br />48"CLEAR12" <br />CLR <br />59" MIN. ATFLR. MTD. W.C.OR 56" MIN. ATWALL MTD. W.C.CLR. FLR. SPACEFIGURE 8.1-BACCESSIBLE COMPARTMENT WITHEND IN-SWING DOOR1/4" VERTICAL <br />RISE MAX. <br />1/2" MAX. <br />RISE60" MIN.SIDE DOORMANEUVERING34" MINCLEAR12"CLR59" MIN. ATFLR. MTD. W.C.OR 56" MIN. ATWALL MTD. W.C.CLR. FLR. SPACE60" MIN.SIDE DOORMANEUVERING18"18"CLR36" MIN.WHEN DR.SWINGS INFIGURE 8.1-AACCESSIBLE COMPARTMENT WITHEND OUT-SWING DOORGRAB BARS:SHALL BE INSTALLED INACCORDANCE WITH DETAILS 10AND 12 OF THIS SHEET.34" MINCLEAR18" <br />18" <br />CLR <br />DOOR PERMITTEDTO SWING OVERHATCHED PORTIONOF MANEUVERINGSPACELOCATE END DOOR DIAGONALTO THE WATER CLOSET4" MAX <br />DOOR PERMITTEDTO SWING OVERHATCHED PORTIONOF MANEUVERINGSPACE36"60" <br />M <br />I <br />N <br />DIA <br />M <br />E <br />T <br />E <br />R <br /> <br />C <br />L <br />E <br />A <br />R <br />60" <br />M <br />I <br />N <br />DIA <br />M <br />E <br />T <br />E <br />R <br /> <br />C <br />L <br />E <br />A <br />R <br />CL <br />18"48" MIN.END DOORMANEUVERING60" MIN. DOOR <br />MANEUVERING & <br />CLR. FLR. SPACE <br />60" MIN. DOOR <br />MANEUVERING & <br />CLR. FLR. SPACE EQ.32" MIN <br />CLEAR <br />4" MAX <br />48" MIN.END DOORMANEUVERING35"-37" <br />60" MIN. DOOR <br />MANEUVERING & <br />CLR. FLR. SPACE <br />60" MIN. DOOR <br />MANEUVERING & <br />CLR. FLR. SPACE <br />12"MAX54" MIN.FIGURE 9.1ACCESSIBLE SINGLE ACCOMMODATIONTOILET WITH SIDE OUT-SWING DOOR60"59" MIN. ATFLR. MTD. W.C.OR 56" MIN. ATWALL MTD. W.C.CLR. FLR. SPACE59" MIN. ATFLR. MTD. W.C.OR 56" MIN. ATWALL MTD. W.C.CLR. FLR. SPACE12"60" MIN <br />CLEAR <br />36"60"FIGURE 9.2ACCESSIBLE SINGLE ACCOMMODATIONTOILET WITH SIDE IN-SWING DOOR48" MINMANEUVERINGSPACE48" MINMANEUVERINGSPACE12"24" <br />60" MIN. DOOR <br />MANEUVERING & <br />CLR. FLR. SPACE LAV. ORFIXTURELAV. ORFIXTURE18"1 1/2" <br />CLR <br />LTOILETPAPERDISPENSERC31" CLEAR10" <br />CLR.PARTITIONOR WALLWHENOCCURSEQ.22" - 23"2 1/2" MAX.60" MIN. FINISH TO FINISH CLEAR1/2" MAX. THRESHOLDSIDE SEAT WALL <br />WALL OR PARTITION19" MIN.33" MIN - 36 MAX. <br />14" - 15"15" - 16"1 1/2" MAX.SHOWER BACK CONTROL WALL ELEVATION FOR FIGURES 16.1 AND 16.3MAXIMUM1/4" : 1'-0" SLOPEFIGURE 16.1 ROLL-IN SHOWER, PLAN VIEWFOLDING <br />SEAT <br />CLEARFLOORSPACEBACK CONTROL WALL36" MIN.30" MIN. <br />FINISH TO FINISH CLEAR <br />60" MIN.SIDE WALLSHOWER SEAT42" MIN.FOLDING <br />SEAT 32" MIN.CLEAR24"MAX.POINTX<48"60" MIN. CLR.PASSING(CORRIDOR OVER 200')48" MIN.OR 36" MIN.IF "X" ≥ 48"60"DOORS SHALLCOMPLY WITH THEREQUIREMENTSOF DETAIL 4 OFTHIS SHEET60" DIAMETER FOR180° TURNS44" MIN.CLEAR≥ 10 OCC.LOAD60" MIN. CLR.PASSINGAT A CENTRALLOCATION60" MIN. CLR.44" MIN. CLR.CORRIDORWIDTHFIGURE 1 - WHEELCHAIR PASSAGECORRIDOR OVER 200'FIGURE 2 - WHEELCHAIR PASSING60"T-SHAPE FOR180° TURNSADDITIONALMANEUVERINGSPACE24"MAX.> 24"48" CLR.> 15"36" CLR.30" CLR.15"MAX.60" CLR."X"48" MAX."X" = 20" MAX.44" MAX."X" > 20" - 25"MAX.48" MAX.48" MAX."X" = 10" MAX.46" MAX."X" > 10" - 24"MAX."X"15"MIN.34" MAX. *FORWARD APPROACH FORWARD REACHPARALLEL APPROACH SIDE REACH30" MIN.30" MIN.CLEAR48" MIN.CLEAR48" MIN.30" CLR.42" CLR.30 MIN.19"MAX.19"MAX.ACCESSIBLE PATH OF TRAVELWHEELCHAIR SEATING SPACEWHEELCHAIR TABLE SPACECONTROLS AND OPERATING MECHANISMS SHALL COMPLY WITH CBC SECTIONS 1138A.4, 1142A AND 11B-309.A.GENERAL.CONTROLS AND OPERATING MECHANISMS IN ACCESSIBLE SPACES, ALONG ACCESSIBLE ROUTES OR AS PART OFACCESSIBLE ELEMENTS AND THOSE REQUIRED TO BE ACCESSIBLE BY CBC SECTION 1.9.1 SHALL COMPLY WITH THEFOLLOWING REQUIREMENTS;B.CLEAR FLOOR SPACE.A CLEAR FLOOR SPACE THAT ALLOWS A FORWARD OR PARALLEL APPROACH BY A PERSON USING A WHEELCHAIRSHALL BE PROVIDED AT CONTROLS AND OPERATING MECHANISMS.C.HEIGHT.CONTROLS AND OPERATING MECHANISMS SHALL BE LOCATED NO HIGHER THAN 48", AND NO LOWER THAN 15", ABOVEFINISHED FLOOR MEASURED TO THE CENTER OF THE GRIP. IF THE REACH IS OVER AN OBSTRUCTION (FOR EXAMPLE,WASTHER OR DRYER), CONTROLS AND OPERATING MECHANISMS SHALL BE LOCATED WITHIN THE REACH RANGESSPECIFIED IN SECTION 1138A.3. SEE DETAIL 22 ON THIS SHEET. CONTROLS AND OPERATING MECHANISMS THAT DONOT SATISFY THESE SPECIFICATIONS ARE ACCEPTABLE, PROVIDED THAT COMPARABLE MECHANISMS, CONTROLS OROUTLETS, THAT PERFORM THE SAME FUNCTIONS, ARE PROVIDED WITHIN THE SAME AREA AND ARE ACCESSIBLE.D.OPERATION.CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHTGRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NOGREATER THAN 5 POUNDS OF FORCE.E.INSTALLATION HEIGHTS OF ELECTRICAL SWITCHES AND RECEPTACLE OUTLETS.1.ELECTRICAL SWITCHES. CONTROLS AND SWITCHES INTENDED FOR USE BY THE OCCUPANT OF THE ROOM ORAREA TO CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES OR COOLING, HEATING AND VENTILATINGEQUIPMENT SHALL BE LOCATED NO MORE THAN 48" MEASURED FROM THE TOP OF THE OUTLET BOX NOR LESSTHAN 15" FROM THE BOTTOM OF THE OUTLET BOX TO THE FINISH FLOOR OF THE WORKING PLATFORM.2.ELECTRICAL RECEPTACLE OUTLETS. ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30 AMPERESOR LESS AND COMMUNICATION SYSTEM RECEPTACLES SHALL BE LOCATED NO MORE THAN 48" MEASURED FROMTHE TOP OF THE OUTLET BOX NOR LESS THAN 15" FROM THE BOTTOM OF THE OUTLET BOX TO THE FINISH FLOOROR THE WORKING PLATFORM. EXCEPTIONS INCLUDE TO FOLLOWING CONDITIONS:a.RECEPTACLE OUTLETS INSTALLED AS PART OF PERMANENTLY INSTALLED BASEBOARD HEATERS AREEXEMPT.b.REQUIRED RECEPTACLE OUTLETS SHALL BE PERMITTED IN FLOORS WHEN ADJACENT TO SLIDING PANELS ORWALLS.c.BASEBOARD ELECTRICAL OUTLETS USED IN RELOCATABLE PARTITIONS, WINDOW WALLS OR OTHERELECTRICAL CONVENIENCE FLOOR OUTLETS ARE NOT SUBJECT TO THE MINIMUM HEIGHT REQUIREMENTS.d.IN EXISTING BUILDINGS WHEN THE ENFORCING AGENCY DETERMINES THAT COMPLIANCE WITH THESESTANDARDS WOULD CREATE AN UNREASONABLE HARDSHIP.9" MIN. <br />27" MIN. @ REAR <br />34" MAX.RIM / COUNTERKNEETOE15" MIN.18" MIN.KNEE48" MIN. <br />17" MIN. <br />25" MAX <br />VANITY COUNTER WITHBUILT-IN LAVATORY SHOWN8" MIN19" MAX.17" MIN.25" MAX.F.F.15" MIN.LAVATORYFIXTURESHOWN6 1/2" MAX. BOWL DEPTH1'-0"1'-0"MEN'S DOORSIGNAGE1'-0"1'-0"SANITARY FACILITY SIGNS SHALL COMPLY WITH CBC SECTIONS 1127A.7 AND 11B-703.CALIFORNIA'S STANDARDS FOR SIGNAGE ARE MORE STRINGENT THAN SECTION 4.30 OF THE ADA STANDARDS FORACCESSIBLE DESIGN. THE INFORMATION PROVIDED WITH IN THIS DETAIL IS INTENDED TO SHOW THE MINIMUMSIGNAGE REQUIRED AT SANITARY FACILITY DOORS ONLY TO OBTAIN A BUILDING PERMIT. IDENTIFICATION,DIRECTIONAL AND INFORMATION SIGNS ARE NOT PART OF THE ARCHITECT'S SCOPE OF WORK.A.ALL ACCESSIBLE TOILET AND BATHING FACILITIES SHALL BE IDENTIFIED BY THE "INTERNATIONAL SYMBOL OFACCESSIBILITY. SIGNS NEED NOT BE PROVIDED FOR FACILITIES WITHIN A DWELLING UNIT OR GUEST ROOM.B.DOORWAYS LEADING TO SANITARY FACILITIES SHALL BE IDENTIFIED BY A GEOMETRIC SYMBOL. GEOMETRICSYMBOLS SHALL BE CENTERED HORIZONTALLY ON THE DOOR AT A HEIGHT OF 58" MIMUMUM TO 60" MAXIMUMABOVE THE FINISH FLOOR OR GROUND SURFACE MEASURED TO THE CENTER OF THE SYMBOL. WHEN A DOORIS PROVIDED, THE SYMBOL SHALL BE MOUNTED WITHIN 1 INCH OF THE VERTICAL CENTERLINE OF THE DOOR.EDGES OF ACCESSIBILITY SIGNS SHALL BE ROUNDED, CHAMFERED OR EASED. CORNERS SHALL HAVE AMINIMUM RADIUS OF 1/8".1.MEN'S SANITARY FACILITIES SHALL BE IDENTIFIED WITH AN EQUILATERAL TRIANGLE 1/4" THICK WITHEDGES 12" LONG AND A VERTEX POINTING UP. THE TRIANGLE SYMBOL SHALL CONTRAST WITH THEDOOR , EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND.2.WOMEN'S SANITARY FACILITIES SHALL BE IDENTIFIED WITH A CIRCLE 1/4" THICK AND 12" IN DIAMETERAND A VERTEX POINTING UP. THE CIRCLE SYMBOL SHALL CONTRAST WITH THE DOOR , EITHER LIGHT ONA DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND.3.UNISEX SANITARY FACILITIES SHALL BE IDENTIFIED BY A CIRCLE 1/4" THICK AND 12" IN DIAMETER WITH A1/4" THICK TRIANGLE SUPERIMPOSED ON THE CIRCLE AND WITHIN THE 12" DIAMETER. THE TRIANGLESYMBOL SHALL CONTRAST WITH THE CIRCLE SYMBOL, EITHER LIGHT ON A DARK BACKGROUND OR DARKON A LIGHT BACKGROUND. THE CIRCLE SYMBOL SHALL CONTRAST WITH THE DOOR , EITHER LIGHT ON ADARK BACKGROUND OR DARK ON A LIGHT BACKGROUND.WOMEN'S DOORSIGNAGEUNISEX DOORSIGNAGE36" MIN.CLEAR< 10 OCC.LOAD24"MAX.POINT 48" MIN.CLEAR <br />INSULATEPLUMBINGPIPES15"MIN.27" MIN.CLEAR34" MAX. <br />60" <br />MINIMUM <br />60" <br />MINIMUM <br />ADDITIONAL MANEUVERING SPACE IF A DOORIS PROVIDED WITH BOTH CLOSER AND LATCHADDITIONAL MANEUVERING SPACE IFA DOOR IS PROVIDED WITH A CLOSERACCESSIBLE ROUTE(S) THROUGH WITHIN THE MULTIFAMILY DEVELOPMENT SHALL COMPLY WITH BUT NOT BELIMITED TO CBC SECTIONS 1117A, 1119A, 1121A AND 11B-DIVISION 4.A.GENERAL. WHEN A BUILDING OR A PORTION OF A BUILDING IS REQUIRED TO BE ACCESSIBLE OR ADAPTABLE,AN ACCESSIBLE ROUTE SHALL BE PROVIDED TO ALL PORTIONS OF THE BUILDING, ACCESSIBLE BUILDINGENTRANCES, TO COVERED MULTIFAMILY DWELLING UNITS AND BETWEEN THE BUILDING AND THE PUBLIC WAY.ALL WALKS, HALLS, CORRIDORS, AISLES, SKYWALKS, TUNNELS AND OTHER SPACES THAT ARE PART OF THEACCESSIBLE ROUTE SHALL COMPLY WITH THE APPLICABLE PROVISIONS OF THE APPLICABLE CODES. AT LEASTONE ACCESSIBLE ROUTE WITHIN THE BOUNDARY OF THE SITE SHALL BE PROVIDED FROM THE PUBLICTRANSPORTATION STOPS, ACCESSIBLE PARKING, ACCESSIBLE PASSENGER LOADING ZONES AND PUBLICSTREETS OR SIDEWALKS TO THE ACCESSIBLE BUILDING ENTRANCE THEY SERVE. THE ACCESSIBLE ROUTESHALL, TO THE MAXIMUM EXTENT FEASIBLE, COINCIDE WITH THE ROUTE FOR THE GENERAL PUBLIC AND OTHERBUILDING RESIDENTS. ACCESSIBLE ROUTES SHALL NOT PASS THROUGH KITCHENS, STORAGE ROOMS,RESTROOMS, CLOSETS OR OTHER SPACES USED FOR SIMILAR PURPOSES EXCEPT WITHIN AN INDIVIDUALDWELLING UNIT. ACCESSIBLE ROUTES SHALL BE PROVIDED AS FOLLOWS:1.WHERE MORE THAN ONE ROUTE OF TRAVEL IS PROVIDED, ALL ROUTES SHALL BE ACCESSIBLE.2.AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT ACCESSIBLE BUILDING OR FACILITY ENTRANCES WITHALL ACCESSIBLE SPACES , ELEMENTS AND COVERED MULTIFAMILY DWELLING UNITS.3.AN ACCESSIBLE ROUTE SHALL CONNECT AT LEAST ONE ACCESSIBLE PRIMARY ENTRANCE OF EACHCOVERED MULTIFAMILY DWELLING UNIT WITH INTERIOR AND EXTERIOR SPACES AND FACILITIES THATSERVE THE UNIT4.WHERE ELEVATORS ARE PROVIDED FOR VERTICAL ACCESS ONLY ONE IS REQUIRED, HOWEVER ALLELEVATORS PROVIDED SHALL BE ACCESSIBLE.B.FLOORING. SHALL COMPLY WITH THE REQUIREMENTS OF DETAIL 22, ITEM D OF THIS SHEET.C.RECESSED DOOR MATS. SHALL COMPLY WITH THE REQUIREMENTS OF DETAIL 6 OF THIS SHEET.D.PRIMARY ENTRANCES AND GROUND FLOOR EXITS. ALL ENTRANCES AND ALL EXTERIOR GROUND FLOOR EXITSSHALL BE ACCESSIBLE.E.SEPARATE DWELLING UNIT ENTRANCES. WHEN A GROUND-FLOOR DWELLING UNIT OF A BUILDING HAS ASEPARATE ENTRANCE, EACH SUCH GROUND-FLOOR DWELLING UNIT SHALL BE SERVED BY AN ACCESSIBLEROUTE EXCEPT WHERE THE SITE TERRAIN PROHIBITS AN ACCESSIBLE ROUTE (SEE CBC SECTION 1150A).F.MULTIPLE ENTRANCES. ONLY ONE ENTRANCE TO COVERED MULTIFAMILY BUILDINGS IS REQUIRED TO BEACCESSIBLE TO ANY ONE GROUND FLOOR OF A BUILDING, EXCEPT IN CASES WHERE AN INDIVIDUAL DWELLINGUNIT HAS A SEPARATE EXTERIOR ENTRANCE. WHERE THE BUILDING CONTAINS CLUSTERS OF DWELLING UNITSWITH EACH CLUSTER SHARING A DIFFERENT EXTERIOR ENTRANCE, MORE THAN ONE ENTRANCE MAY BEREQUIRED TO BE ACCESSIBLE AS DETERMINED BY ANALYSIS OF THE SITE TERRAIN. IN EVERY CASE, THEACCESSIBLE ENTRANCE SHALL BE ON AN ACCESSIBLE ROUTE TO THE COVERED MULTIFAMILY DWELLING UNITIT SERVES.G.INTERIOR WIDTHS AND LENGTHS. SHALL COMPLY WITH THE REQUIREMENTS OF DETAIL 22, ITEM A OF THISSHEET. IF A PERSON IN A WHEEL CHAIR MUST MAKE A TURN AROUND A CORNER OR OBSTRUCTION THEACCESSIBLE ROUTE SHALL COMPLY WITH DETAIL 22, ITEM B OF THIS SHEET.H.CHANGES IN LEVEL NOT EXCEEDING 1/2". ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALLNOT EXCEED 1/2". WHEN CHANGES IN LEVEL DO OCCUR, THEY SHALL BE BEVELED WITH A SLOPE NO GREATERTHAN 1 UNIT VERTICAL IN 2 UNITS HORIZONTAL (50% SLOPE). CHANGES IN LEVEL NOT EXCEEDING 1/4" MAY BEVERTICAL.I.CHANGES IN LEVEL GREATER THAN 1/2". CHANGES IN LEVEL GREATER THAN 1/2" SHALL BE MADE BY MEANS OFA SLOPED SURFACE WITH A SLOPE NOT GREATER THAN 1 UNIT VERTICAL IN 20 UNITS HORIZONTAL (5% SLOPE),OR A CURB RAMP PER CBC SECTION 1112A, A RAMP PER CBC SECTION 1114A EXTERIOR RAMPS OR 1122AINTERIOR RAMPS, ELEVATOR PER CBC SECTION 3003 OR PLATFORM WHEELCHAIR LIFT PER CBC SECTION1124A. WHEN STAIRS ARE LOCATED ALONG OR ADJACENT TO AN ACCESSIBLE ROUTE THEY SHALL COMPLYWITH CBC SECTION 1115A EXTERIOR STAIRWAYS OR 1123A INTERIOR STAIRWAYS.29" MIN. @ FRONT ACCESSIBLE PATH OF TRAVEL12"48"6"30"24"MIN.36" MIN.48" MIN60" MIN.42" MIN.36" MIN.AT EXTERIOR DOORSAT INTERIOR DOORS18"18" <br />18" <br />18"44"MIN. CLR.60" MIN.36" x 48"CLR.6" MAX.3" MAX.COMPARTMENT <br />OPENING <br />11" MINSANITARYNAPKINDISPOSALCOMMON & PUBLICAREA ACCESSIBILITYNOTES & DETAILSAD-02818144DOORS6LAVATORY1623URINALWATER CLOSET1GENERAL NOTESLANDINGS & THRESHOLDSSHOWER1024LAUNDRY ROOMSSTORAGE & BUILT-INS12GRAB BARS & SHOWER SEATSTOILET COMPARTMENTSTOILET ROOM LAYOUT917SANITARY FACILITY SIGNAGE22FIXTURES AND ACCESSORIES13CONTROLS & OPERATION2ACCESSIBLE ROUTESPACE & REACH RQMTS.CCOPYRIGHTIt is the clients responsibility prior to or during construction to notify the architect in writingof any perceived errors or omissions in the plans and specifications of which a contractorthoroughly knowledgeable with the building codes and methods of construction shouldreasonably be aware. Written instructions addressing such perceived errors or omissionsshall be received from the architect prior to the client or clients subcontractors proceedingwith the work. The client will be responsible for any defects in construction if theseprocedures are not followed.Architecture + Planning17911 Von Karman Ave.Suite 200Irvine, CA 92614ktgy.com949.851.2133License StampProject Contact:Email:Principal: Project Designer:Project Director:KTGY Project No:2017-0934Debbie Hollanddholland@ktgy.comWil WongD. SchoolmeesterDebbie HollandDeveloperPHONE NO.4199 CAMPUS DRIVEIRVINE, CA 92612(714) 342-2502415 & 515 E. 4TH STREET, SANTA ANA, CA 92701 <br />4TH AND MORTIMERNo.Date Description06-21-2023 FIFTH BUILDING DEPARTMENT SUBMITTALA03-21-23ADDENDUM A11AAAAA06-21-23