My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Item 30 - 4th and Mortimer Mixed-Use Development Project Located at 409 and 509 East Fourth Street
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2024
>
11/19/2024
>
Item 30 - 4th and Mortimer Mixed-Use Development Project Located at 409 and 509 East Fourth Street
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 3:06:42 PM
Creation date
11/15/2024 9:08:22 AM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Planning & Building
Item #
30
Date
11/19/2024
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
306
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ISOLATE BASEBOARDABOVE FINISH FLOORACOUSTICAL-FIRE SEALANT14" THICK PERIMETERISOLATOR BETWEEN WALLAND GYP-CRETE FLOORUNDERLAYMENTSUBFLOOR14" MIN. GAP, FILL WITHACOUSTICAL FIRE RATEDSEALANT.ISOLATE BASEBOARDABOVE FINISH FLOORACOUSTICAL FIRE RATEDSEALANTONE OR TWO LAYERS GYP. BD.WHERE OCCURS O/ PLYWOODSHEAR WALL WHERE OCCURSINSTALL WALL BOARD MIN. 12"ABOVE SUBFLOORSLABCARPET OR HARD SURFACEFLOORINGR.C.CHANNELS14" MIN. GAP. CAULK WITHACOUSTICAL FIRE RATEDSEALANT.CONCRETE SLAB. MIN. 6.2INCH THICK FOR 3 HR RATINGPER CBC TABLE 722.2.2.1.REFER TO PLANS FORDESIGN THICKNESS.ASSEMBLY COMPLIES WITH:CBC TABLE 721.1(3) ITEM 1-1.1TUBSLAB BLOCK-OUT FORDRAINAGE LINES.3"12"8"3 HR RATED FIRESTOPPINGAT THE SLAB PENETRATIONWATERPROOFING OVERMETAL PAN INSERT.SHAFT WALL PER PLANPER PLANPER PLAN2 HR RATED SHAFT ASSEMBLYPER GA FILE No. 7125.CONCRETE SLABCONCRETE OR CMU WALLFINISH FLOOR WHEREOCCURSCONCRETE SLAB. MIN. 5.0INCH THICK FOR 2 HR RATINGPER CBC TABLE 721.1(3) Item1-1.1. REFER TO PLANS FORDESIGN THICKNESS.ASSEMBLY COMPLIES WITH:CBC TABLE 721.1(3) ITEM 1-1.1DOUBLE WOOD FLOOR7/8" THK EXTERIOR PLASTER OVEREXTENDED METAL LATH 2X WOOD FLOOR JOISTSMAX. 16" O.C.PLIDEK SYSTEMWATERPROOFING PER WATERPROOFINGREPORT DOUBLE WOOD FLOOR2X WOOD FLOOR JOISTSMAX. 16" O.C. 2 12" HARDROCK CONCRETE DRAINAGE BOARD OVERWATERPROOFING MEMBRANEONE LAYER 5/8"PROPRIETERY GYPSUMBOARD7/8" THK EXTERIOR PLASTER OVEREXTENDED METAL LATH ONE OR TWO LAYERS GYP. BD.WHERE OCCURS O/ PLYWOODSHEAR WALL WHERE OCCURSINSTALL WALL BOARD MIN. 12"ABOVE SUBFLOORONE OR TWO LAYERS GYP. BD.WHERE OCCURS O/ PLYWOODSHEAR WALL WHERE OCCURSONE OR TWO LAYERS GYP. BD.WHERE OCCURSASSEMBLY COMPLIES WITH:CBC TABLE 721.1 (3) ITEM 13-1.2ASSEMBLY COMPLIES WITH:CBC TABLE 721.1 (3) ITEM 13-1.2PROVIDE 2 MM THICK MIN.ACOUSTICAL UNDERLAYMENTWHEN OCCURS ABOVE ADWELLING UNIT ORCONFERENCE ROOM ANDHARD SURFACE FLOORING ISUSEDFINISH FLOOR WHEREOCCURSPROVIDE 2 MM THICK MIN.ACOUSTICAL UNDERLAYMENTWHEN OCCURS ABOVE ADWELLING UNIT ORCONFERENCE ROOM ANDHARD SURFACE FLOORING ISUSEDFIRE-RATEDFLOOR-CEILINGASSEMBLIES (CONT.)AD-21CCOPYRIGHTIt is the clients responsibility prior to or during construction to notify the architect in writingof any perceived errors or omissions in the plans and specifications of which a contractorthoroughly knowledgeable with the building codes and methods of construction shouldreasonably be aware. Written instructions addressing such perceived errors or omissionsshall be received from the architect prior to the client or clients subcontractors proceedingwith the work. The client will be responsible for any defects in construction if theseprocedures are not followed.Architecture + Planning17911 Von Karman Ave.Suite 200Irvine, CA 92614ktgy.com949.851.2133License StampProject Contact:Email:Principal: Project Designer:Project Director:KTGY Project No:2017-0934Debbie Hollanddholland@ktgy.comWil WongD. SchoolmeesterDebbie HollandDeveloperPHONE NO.4199 CAMPUS DRIVEIRVINE, CA 92612(714) 342-2502415 & 515 E. 4TH STREET, SANTA ANA, CA 92701 <br />4TH AND MORTIMERNo.Date Description06-21-2023 FIFTH BUILDING DEPARTMENT SUBMITTALA06-21-23ADDENDUM A3-HR RATED FLOOR/CEILING2-HR RATED FLOOR/CEILINGWALL TO CEILING ISOLATION2-HR RATED SOFFITSLAB CUT-OUT AT TUBWALL TO FLOOR ISOLATIONWALL TO SLAB ISOLATION161514201918242322131721--1-HR FLR/CEILING DECK ASSEMBLY1-HR FLR/CEILING AT EXT. CORR-AA06-21-23